SERVOTOUGH LaserSP Mini |
|
|
|
07930A1 |
|
|
Talking PN Reference |
Analyser Reference |
07931A1- |
Mounting Reference |
07931M- |
Accessories Reference |
07931AA- |
|
|
ANALYSER CONFIGURATION |
|
|
|
Analyser Type |
SP Mini |
|
|
Measurement 1 |
A - Oxygen Low Temperature (<500 C) |
|
F - Ammonia |
|
|
Measurement 1, Range |
|
|
B 0-15 ppm |
|
C 0-25 ppm |
|
D 0-50 ppm |
|
E 0-100 ppm |
|
F 0-200 ppm |
|
G 0-250 ppm |
|
H 0-500 ppm |
|
J 0-1000 ppm |
|
K 0-2500 ppm |
|
L 0-5000 ppm |
|
R 0-1% |
|
S 0-5% |
|
T 0-10% |
|
U 0-21% |
|
V 0-25% |
|
|
Area Classification |
Safe Area / General Purpose |
|
ATEX GAS Category 3G / IECEx Zone 2 |
|
CSA Class 1 Division 2 |
|
ATEX DUST Only Category 2D / IECEx Zone 21 |
|
|
Total Path Length |
< 2m (standard colimated Beam) |
|
2m to 12 m (standard optics - Beam Divergence 0.8) |
|
> 12m (long pathlength optics - Beam Divergence 0.6) |
|
|
Additional Inputs/Outputs |
None (standard 1 x 4-20 mA output, 1 x relays) |
|
Required (additional 1 x mA output, 2 x 4-20 mA input, 2 x relays) |
|
|
Process Pressure / Temperature |
<= 1.5barA & <=500°C |
|
>1.5barA to 16barA & <=500°C |
|
|
MOUNTING CONFIGURATION |
|
|
|
Isolation Flange |
None |
|
Customer Supplied |
|
DN50 |
|
2" ANSI |
|
|
Tx Mounting Type |
Fixed |
|
Premium - Ball Joint |
|
|
Tx Flange Size |
DN25 |
|
DN50 |
|
1" ANSI |
|
2" ANSI |
|
3" ANSI |
|
|
Rx Mounting Type |
Fixed |
|
Premium - Ball Joint |
|
|
Rx Flange Size |
DN25 |
|
DN50 |
|
1" ANSI |
|
2" ANSI |
|
3" ANSI |
|
|
Seal Material (Sample Wetted) |
Fluorocarbon (Viton 70) |
|
Chemraz (Chemraz 505) |
|
|
Insertion Tubes |
None |
|
2" ANSI 316SS Narrow Bore |
|
2" ANSI 316SS Standard Bore |
|
DN50 316SS Standard Bore |
|
2"ANSI Combo I F / 316SS S B |
|
|
Thermal Break |
None |
|
DN25 |
|
DN50 |
|
1" ANSI |
|
2" ANSI |
|
|
|
|
|
3" ANSI |
|
|
In Line Span Cell |
None |
|
Required |
Accessories CONFIGURATION |
|
Analyser Purge |
|
|
|
Window Purge |
None |
|
Instrument Air |
|
Nitrogen |
|
|
Measurement Purge |
Blanked |
|
Instrument Air |
|
Nitrogen |
|
|
Environmental Purge |
None |
|
Instrument Air |
|
Nitrogen |
|
|
Purge Fitting Type |
None (1/8" NPT F) |
|
Metric (6mm Compression Fittings) |
|
Imperial (1/4" Compression Fittings) |
|
|
Purge Panel |
None |
|
Option 1 - Window Purge Only |
|
Option 2 - Window Purge plus Cal Cell |
|
Option 3 - Window and case Purge |
|
Option 4 - Window and case Purge plus Cal Cell |
|
Option 5 - Purge Windows, Case, Laser and Detector |
|
Option 6 - Purge Windows, Case, Laser and Detector plus cal cell |
|
|
Power supply |
24 V dc |
|
100-240 V / 50-60 Hz External Transformer |
|
|
Manuals: User / Installation / Safety |
English |
|
|
Manuals: Service |
None |
|
English |
|
|
Alignment Tool |
None |
|
|
Calibration Cell Kit |
None |
|
250 mm |
|
500 mm |
|
750 mm |
|
1000 mm |
|
|
InterConnection Cable |
None |
|
Servomex Standard |
|
|
Interconnection Cable length |
|
|
Interconnection cable / M |
|
|
|
|
|
|
|
|
SERVOPRO MULTIEXACT GAS PURITY ANALYSER |
|
05410A1 |
|
Base Analyser |
|
|
|
Supply |
|
|
UK Power Lead |
|
European Power Lead |
|
American Power Lead |
|
|
Gas Module 1 |
|
|
O2 Purity |
|
O2 Control |
|
O2 Trace |
|
0-10 ppm CO2 Trace |
|
0-500 ppm CO2 Trace |
|
0-20 ppmN2O Trace |
|
0-10 ppm CO Trace |
|
Thermal Conductivity - Ar |
|
Thermal Conductivity - N2 |
|
Thermal Conductivity - He |
|
|
Sample System Module 1 |
|
|
Flow Driven Paramagnetic |
|
Flow Driven Zirconia |
|
Flow Driven Gfx |
|
Pressure Driven Paramagnetic |
|
Pressure Driven Zirconia |
|
Pressure Driven Gfx |
|
|
Fascia Options Module 1 |
|
|
Blank |
|
Sample Flowmeter |
|
Bypass Flowmeter |
|
Sample + Bypass Flowmeter |
|
Filter (Pm only) |
|
Filter (Pm only) + Sample Flowmeter |
|
Filter (Pm only) + Bypass Flowmeter |
|
|
Gas Module 2 |
|
|
O2 Purity |
|
O2 Control |
|
O2 Trace |
|
0-10 ppm CO2 Trace |
|
0-500 ppm CO2 Trace |
|
0-20 ppmN2O Trace |
|
0-10 ppm CO Trace |
|
Thermal Conductivity - Ar |
|
Thermal Conductivity - N2 |
|
Thermal Conductivity - He |
|
|
Sample System Module 2 |
|
|
Flow Driven Paramagnetic |
|
Flow Driven Zirconia |
|
Flow Driven Gfx |
|
Pressure Driven Paramagnetic |
|
Pressure Driven Zirconia |
|
Pressure Driven Gfx |
|
|
Fascia Options Module 2 |
|
|
Blank |
|
Sample Flowmeter |
|
Bypass Flowmeter |
|
Sample + Bypass Flowmeter |
|
Filter (Pm only) |
|
Filter (Pm only) + Sample Flowmeter |
|
Filter (Pm only) + Bypass Flowmeter |
|
|
External Filter Module 1 |
|
|
Not Supplied |
|
Particulate Filter (not Zirconia) |
|
|
External Filter Module 2 |
|
|
Not Supplied |
|
Particulate Filter (not Zirconia) |
|
|
Flow Alarm |
|
Flow Alarm Module 1 |
Not required |
|
Flow Alarm |
|
|
|
|
Flow Alarm Module 2 |
Not required |
|
Flow Alarm |
|
|
Analogue Outputs |
|
Gas Module 1 |
mA Analogue Output |
|
Voltage Analogue Output |
|
|
|
|
|
|
Gas Modules 1 & 2 |
mA Analogue Output |
|
Voltage Analogue Output |
|
|
Valve Block |
(requires AutoVal/Cal relays) |
|
Not required |
Gas Module 1 |
Required |
|
|
|
Not required |
Gas Modules 1 and 2 |
Required |
|
|
AutoVal / Cal relays |
|
|
Not required |
Gas Module 1 |
AutoVal / Cal required |
|
|
|
Not required |
Gas Modules 1 & 2 |
AutoVal / Cal required |
|
|
|
|
Alarm / Status Relays |
|
|
Not required |
Gas Module 1 |
Relay required |
|
|
|
Not required |
Gas Modules 1 & 2 |
Relay required |
|
|
Digital Communications |
|
|
ModBus RS485 |
|
ModBus TCP (Ethernet) |
|
ProfiBus |
|
|
Mounting |
|
|
Bench |
|
19" Rack Mount Ears Only |
|
19" Rack Slide Mount |
|
|
Operators Manual |
|
|
English |
|
French |
|
German |
|
|
Back Pressure Valve (External) |
|
|
Required |
|
|
|
|
|
|
|
|
|
|
SERVOPRO MonoExact TCD GAS ANALYSER |
|
|
|
05512A1 Base Analyser |
|
|
|
GAS MODULE CONFIGURATION |
|
|
|
Gas Module |
Thermal Conductivity |
|
|
Sample/Background Gas |
Ar in N2/O2/Air |
|
N2 in Ar |
|
He in N2 |
|
He in O2 |
|
|
Range |
0 -2% Only available for "He in N2" or "He in O2" |
(Check VC for permitted ranges) |
0 - 5% Only available for "He in N2" or "He in O2" |
0 - 10% |
0 - 20% |
0 - 30% Only available for "He in N2" or "He in O2" |
0 - 50% Not available for "N2 in Ar" |
0 - 100% Not available for "N2 in Ar" |
80 - 100% Not available for "N2 in Ar" |
90 - 100% Not available for "N2 in Ar" |
|
|
Sample System |
Flow Driven |
|
Pressure Driven |
|
|
Fascia Options |
Blank |
|
Sample Flowmeter |
|
Filter |
|
|
GENERAL CONFIGURATION |
. |
|
|
Power Supply |
UK Power Lead |
|
European Power Lead |
|
American Power Lead |
|
|
Analogue Output |
mA Output |
|
Voltage Output (0-10V) |
|
|
Digital Output |
Not Required |
|
ModBus RS485 |
|
ModBus TCP (Ethernet) |
|
Profibus |
|
|
Relay Option Card |
Not Required |
|
Alarms & Status |
|
Auto Val / Cal |
|
|
Mounting Option |
Bench |
|
Panel |
|
Rack |
|
|
User Manual |
English |
|
English (Russian MultiExact HW) |
|
|
|
|
|
|