Model |
Description |
10 |
MULTIMETER - Discontinued - replaced by Fluke 115 |
103232 |
HOOD, ANTI-GLARE - Discontinued - no replacement |
104300 |
BATTERY, 12V, 2000MAH, IR INSIGHT - Discontinued - no replacement |
104351 |
Power Adapter, Turck Cord, IR Flexcam |
104354 |
Strap, Neck, IR Flexcam - Discontinued - no replacement |
104402 |
CHARGER, PANASONIC BATTERY CH-PA02305 - Discontinued - no replacement |
104411 |
Padded Neck Strap |
104417 |
STRAP, HARNESS, IR INSIGHT - Discontinued - no replacement |
104536 |
CHARGER,PANASONIC BATTERY CH-PA02305 W/ CE MRK - Discontinued - no replacement |
104543 |
VEHICLE ADAPTER, BATTERY CHARGER, FLEXCAM |
104585 |
Cord, Power, Flexcam Power Supply |
104695 |
Compact Flash, Type 1 With Adapter |
104831 |
Laser Pointer Assembly, Insight |
105064 |
Micro Fiber Cloth, Flexcam - Discontinued - no replacement |
105122 |
CASE, CARRY, BLACK, IR INSIGHT - Discontinued - no replacement |
105123 |
CASE, CARRY, FLEXCAM |
11 |
MULTIMETER - Discontinued - replaced by Fluke 115 |
110 |
Trms Multimeter, No Amps (Us, Fr, Sp, Por) - Discontinued - replaced by Fluke 115 |
111 |
TRMS Multimeter (Us, Fr, Sp, Por) - Discontinued - replaced by Fluke 115 |
112 |
TRMS Multimeter W/Backlight(Us,Fr,Sp,Por) - Discontinued - replaced by Fluke 117 |
112/322 KIT |
ElectricianS Multimeter And Clamp Meter Combo Kit - Discontinued - replaced byFluke 116/322 KIT |
113 |
UTILITY MULTIMETER |
|
*FREE IWH C-66 CASE* |
114 |
ELECTRICAL TRMS MULTIMETER |
|
*FREE IWH C-66 CASE* |
115 |
TRUE RMS MULTIMETER |
|
*FREE IWH C-66 CASE* |
116 |
HVAC TRUE RMS MULTIMETER |
|
*FREE IWH C-66 CASE* |
116/322 KIT |
HVAC TRUE RMS MULTIMETER AND CLAMP METER COMBO KIT |
116/62 |
HVAC MULTIMETER & IR THERMOMETER COMBO KIT |
117 |
ELECTRICIANS TRUE RMS MULTIMETER |
|
*FREE IWH C-66 CASE* |
117/322 |
ELECTRICIANS MULTIMETER AND CLAMP METER COMBO KIT |
12 |
Multimeter - Discontinued - replaced by Fluke 114 or Fluke 116 |
123/3 |
INDUSTRIAL SCOPEMETER 20MHZ |
123/3-Refurb |
-Refurb Model INDUSTRIAL SCOPEMETER 20MHZ - Discontinued - replaced byFluke 123/3 |
123/3S |
INDUSTRIAL SCOPEMETER 20MHZ |
123/3S-Refurb |
-Refurb Model INDUSTRIAL SCOPEMETER 20MHZ - Discontinued - replaced byFluke 123/3S |
1230 |
RPM MULTIPOINT ENCLOSURE |
124/3 |
INDUSTRIAL SCOPEMETER 40MHZ |
124/3-Refurb |
-Refurb Model SOLD OUT INDUSTRIAL SCOPEMETER 40MHZ - Discontinued - replaced by Fluke 124/3 |
124/3S |
INDUSTRIAL SCOPEMETER 40MHZ |
125/3 |
40MHZ INDUSTR.SCOPEMETER,N AMERICA |
125/3-Refurb |
Refurb Model 40MHZ INDUSTR.SCOPEMETER,N AMERICA |
125/3S |
40MHZ INDUSTR.SCOPEM+SCC,N AMERICA |
125/3S-Refurb |
-Refurb Model SOLD OUT 40MHZ INDUSTR.SCOPEM+SCC,N AMERICA -Discontinued - replaced by Fluke 125/3S |
12B |
MULTIMETER - Discontinued - replaced by Fluke 115 |
1503 |
INSULATION TESTER |
1503/EX LEAD |
EXTENDED LEAD KIT, INSULATION TESTER W/50FT TEST LEAD |
1507 |
INSULATION TESTER |
1520 |
Megohmmeter - Discontinued - replaced by Fluke 1587 or Fluke 1507 |
1550 |
MEGOHMMETER - Discontinued - replaced by Fluke 1550C |
1550B |
5KV MEGOHMMETER - Discontinued - replaced by Fluke 1550C |
1550C |
5KV INSULATION TESTER |
1550C/KIT |
5KV INSULATION TESTER KIT |
1555 |
10KV INSULATION TESTER |
1555/KIT |
10KV INSULATION TESTER KIT |
1577 |
INSULATION MULTIMETER |
|
*FREE IWH C-66 CASE* |
1587 |
INSULATION MULTIMETER |
|
*FREE IWH C-66 CASE* |
1587 ET |
ADVANCED ELECTRICAL TROUBLESHOOTING KIT |
1587 MDT |
ADVANCED MOTOR & DRIVE TROUBLESHOOTING KIT |
1587 T |
INSULATION MULTIMETER |
16 |
Multimeter - Discontinued - replaced by Fluke 116 |
16/322 KIT |
Hvac Multimeter & Clamp Meter Combo Kit - Discontinued - replaced by Fluke 116/322 KIT |
1621 |
EARTH GROUND TESTER |
1621 KIT |
EARTH GROUND TESTER KIT |
1623 |
BASIC GEO EARTH GROUND TESTER |
1623 KIT |
BASIC GEO EARTH GROUND TESTER |
1625 |
ADVANCED GEO EARTH GROUND TESTER |
1625 KIT |
ADVANCED GEO EARTH GROUND TESTER |
1625 KIT-Refurb |
Factory Refurbished, Like New!!! Full Warranty ADVANCED GEO EARTH GROUND TESTER - Discontinued - replaced by Fluke 1625 KIT |
1630 |
EARTH GROUND CLAMP |
1650/013A |
BASIC POWER RECORDER, US |
1650/013C |
POWER RECORDER W/PCON, US |
1650/013D |
POWER RECORDER W/PQ, PCON, US |
1650/013E |
POWER RECORDER W/HARM, US |
1650/013F |
POWER RECORDER W/PQ, HARM, US |
1650/013G |
POWER RECORDER W/PCON, HARM, US |
1650/013H |
POWER RECORDER W/PQ, PCON, HARM, US |
1650/033H |
POWER RECORDER W/PQ, PCON, HARM, MULTI, US |
1650/113B |
POWER RECORDER, HI-SPEED, US |
1650/113D |
POWER RECORDER, HI-SPD W/PCON, US |
1650/113F |
POWER RECORDER, HI-SPD W/HARM, US |
1650/113H |
POWER RECORDER, HI-SPD W/PCON, HARM, US |
1650/113J |
POWER RECORDER, HI-SPD, W/HSPQ, US |
1650/113L |
POWER RECORDER, HI-SPD, W/HSPQ, HARM, US |
1650/113M |
POWER RECORDER, HI-SPD, W/HSPQ, PCON, HARM, US |
1650/133H |
POWER RECORDER, HI-SPD, W/PCON, HARM, MULTI, US |
1650/133J |
POWER RECORDER, HI-SPD, W/HSPQ, MULTI, US |
1650/133L |
POWER RECORDER, HI-SPD, W/HSPQ, HARM, MULTI, US |
1650/133M |
PWR RCDR,HI-SPD,W/HSPQ,PCON,HARM,MULTI,US |
1650/213A |
POWER RECORDER, HOSTILE, US |
1650/213C |
POWER RECORDER, HOSTILE, W/PCON, US |
1650/213E |
POWER RECORDER, HOSTILE, W/HARM, US |
1650/213G |
POWER RECORDER, HOSTILE, W/PCON, HARM, US |
1650/313H |
PWR RECORDER, HOSTILE, HI-SPD, W/PCON, HARM, US |
1650/313M |
PWR RCDR, HSTL,HI-SPD W/HSPQ PCON, HARM US |
1650/333H |
POWER RECORDER, HOSTILE, HI-SPD, HARM, MULTI, US |
1650/333M |
PWR RCDR,HSTL,HI-SPD W/HSPQ,PCON, HARM,MULTI,US |
1695-FLEXI PACK |
1650/113M PWR RCDR W/PAS,RW,4X3210,3110 |
1735 |
POWER LOGGER - ANALYST |
1735/I20/200 |
POWER LOGGER WITH 4 PHASE CURRENT CLAMP SET |
1743 |
POWER QUALITY LOGGER - MEMOBOX |
1743 BASIC |
POWER QUALITY LOGGER (WITHOUT PROBES) |
1743/44 POLESET |
POLE MOUNTING KIT FOR 1743/44 |
1744 |
POWER QUALITY LOGGER - MEMOBOX |
1744 BASIC |
POWER QUALITY LOGGER (WITHOUT PROBES) |
1744/1PH |
POWER QUALITY LOGGER, 1 PHASE |
1744/1V |
POWER QUALITY LOGGER, 1 PH VOLTAGE |
1744/3V |
POWER QUALITY LOGGER 3 PH VOLTAGE |
1745 |
POWER QUALITY LOGGER - MEMOBOX |
1745 BASIC |
POWER QUALITY LOGGER (WITHOUT PROBES) |
175 |
TRMS MULTIMETER |
|
*FREE IWH C-66 CASE* |
1750 |
POWER RECORDER |
1750/B |
BASIC POWER RECORDER |
1750/CASE |
TRANSIT CASE, MOLDED, FLK-1750 AND 1760 |
1750/MC |
512MB MEM CRD, SECURE DIGITAL,2.7V-3.64,BULK - Discontinued - replaced byFluke 1750/MC2GB |
1750/MC2GB |
1750 2GB SECURE DIGITAL MEMORY CARD |
1750/SEAT-L |
1 SEAT LICENSE FOR FLUKE-1750 PWR ANALYZER SOFTWARE |
1750/SITE-L |
1 SITE LICENSE FOR FLUKE-1750 PWR ANALYZER SOFTWARE |
1760 BASIC |
POWER QUALITY RECORDER-TOPAS,W/O V OR I PROBES,NO TRANS |
1760 TR US |
POWER QUALITY RECORDER W/TRANS-TOPAS,CONFIGURED US/CAN RANGE |
1760 US |
POWER QUALITY RECORDER - TOPAS,CONFIGURED US/CAN RANGE,NO TRANS |
1760TR BASIC |
POWER QUALITY RECORDER W/TRANS - TOPAS,W/O V OR I PROBES |
177 |
TRMS MULTIMETER W/BACKLIGHT |
|
*FREE IWH C-66 CASE* |
179 |
TRMS MULTIMETER W/BACKLIGHT & TEMP |
|
*FREE IWH C-66 CASE* |
179/1AC KIT |
Electricians Multimeter, Voltage Tester, And Deluxe Accessory Combo Kit -Discontinued - replaced by Fluke 179/1AC-II KIT |
179/1AC-II |
ELECTRICIANS DMM, VOLTAGE TESTER, AND DELUXE ACCESSORY KIT |
179/1AC-II KIT |
ELECTRICIANS DMM, VOLTAGE TESTER, AND DELUXE ACCESSORY KIT |
179/61 KIT |
IND DMM & INFRARED THERMOMETER COMBO KIT |
179/EDA KIT |
Electronics Multimeter And Deluxe Accessory Combo Kit - Discontinued - replaced by Fluke 179/EDA2 KIT |
179/EDA2 KIT |
ELECTRONICS DMM AND DELUXE ACCESSORY COMBO KIT |
179/IMSK |
INDUSTRIAL MULTIMETER SERVICE KIT |
179/IMSK+ |
INDUSTRIAL MULTIMETER SERVICE KIT with IWH-C66 Case |
179/TPAK |
FLUKE-179 WITH TPAK |
18 |
AUTOMOTIVE MULTIMETER - Discontinued - replaced by Fluke 115 |
187 |
True Rms Multimeter - Discontinued - replaced by Fluke 287 |
189 |
Logging Multimeter - Discontinued - replaced by Fluke 289 |
189/FVF |
Discontined. - Discontinued - replaced by Fluke 289/FVF |
189/FVF2 |
Fluke 189,Flukeview Forms,Bp189,Usb,Efsp - Discontinued - replaced by Fluke 289/FVF |
190-104/AM |
SCOPEMETER 4 CHANNEL 100 MHZ COLOR AMERICAS |
190-104/AM/S |
SCOPEMETER 4 CHANNEL 100 MHZ COLOR AMERI SCC |
190-204/AM |
SCOPEMETER 4 CHANNEL 200 MHZ COLOR AMERICAS |
190-204/AM/S |
SCOPEMETER 4 CHANNEL 200 MHZ COLOR AMERI SCC |
192/003 |
ScopeMeter - Discontinued - no replacement |
192/003S |
ScopeMeter - Discontinued - no replacement |
192B/3 |
SCOPEMETER 60MHZ B/W USA - Discontinued - replaced by Fluke 192C/3 |
192B/3-Refurb |
-Refurb Model SCOPEMETER 60MHZ B/W USA - Discontinued - replaced by Fluke 192C/3 |
192B/3S |
SCOPEMETER 60MHZ B/W SCC USA - Discontinued - replaced by Fluke 192C/3S |
192B/3S-Refurb |
SCOPEMETER 60MHZ B/W SCC USA - Discontinued - replaced by Fluke 192C/3S |
192C/3 |
SCOPEMETER 60 MHZ COLOR NORTHAMERICA |
192C/3S |
SCOPEMETER 60 MHZ COLOR NORTHAMERICA SCC |
1941/0 |
MULTIPOINT POWER RECORDER, TCP/IP |
1941/3 |
MULTIPOINT, W/MULTI-SESSION, TCP/IP |
1942/0 |
MULTIPOINT, EXT CT, TCP/IP |
1942/3 |
MULTIPOINT, EXT CT, MULTI-SESSION, TCP/IP |
1948/0 |
MULTIPOINT HI-SPEED, TCP/IP |
1948/3 |
MULTIPOINT, HI-SPEED, W/MULT-SESSION, TCP/IP |
1949/0 |
MULTIPOINT HI-SPEED, EXT CT, TCP/IP |
1949/3 |
MULTIPOINT, HI-SPEED, EXT CT, W/MULTI-SESSION, TCP/IP |
1950/RPM |
MULTIPOINT BASE UNIT, CE, UL MARKED |
1951/0 |
MULTIPOINT SYSTEM, TCP/IP, 1950 BASE UNIT |
1951/3 |
MULTIPOINT SYSTEM, TCP/IP, MULTI-SESSION, 1950 BASE |
1952/0 |
MULTIPOINT SYSTEM, EXT CT, TCP/IP, 1950 BASE UNIT |
1952/3 |
MULTIPOINT SYS, EXT CT, MULTI-SESSION, TCP/IP, 1950 BASE |
1958/0 |
MULTIPOINT SYSTEM, HI-SPEED, TCP/IP, 1950 BASE UNIT |
1958/3 |
MULTIPOINT SYS, HI-SPD, MULTI-SESSION, TCP/IP, 1950 BASE |
1959/0 |
MULTIPOINT SYSTEM, HI-SPD, EXT CT, TCP/IP, 1950 BASE UNIT |
1959/3 |
MULTIPOINT SYS, HI-SPD, X CT, MULTI-SESSION,TCP/IP,1950 BASE |
196/003 |
ScopeMeter - Discontinued - no replacement |
196/003S |
ScopeMeter - Discontinued - no replacement |
196B/3 |
SCOPEMETER 100MHZ B/W USA - Discontinued - replaced by Fluke 196C/3 |
196B/3-Refurb |
SCOPEMETER 100MHZ B/W USA (Refurbished) - Discontinued - no replacement |
196B/3S |
SCOPEMETER 100MHZ B/W SCC USA - Discontinued - replaced by Fluke 196C/3S |
196B/3S-Refurb |
SCOPEMETER 100MHZ B/W SCC USA (Refurbished) - Discontinued - replaced byFluke 196C/3S |
196BM |
SCOPEMETER 100 MHZ B/W MEDICAL UNIVERSAL - Discontinued - replaced byFluke 196BM/3 |
196BM/3 |
SCOPEMETER 100 MHZ B/W MEDICAL,USA ONLY - Discontinued - no replacement |
196C/3 |
SCOPEMETER 100MHZ COLOR USA |
196C/3-Refurb |
SCOPEMETER 100MHZ COLOR SCC USA - Refurbished - Discontinued - replaced by Fluke 196C/3 |
196C/3S |
SCOPEMETER 100MHZ COLOR SCC USA |
196C/3S-Refurb |
SCOPEMETER 100MHZ COLOR SCC USA - Refurbished - Discontinued - no replacement |
196CM |
SCOPEMETER 100 MHZ COLOR MEDICAL UNIVERSAL - Discontinued - replaced by Fluke 196CM/3 |
196CM/3 |
SCOPEMETER 100 MHZ COLOR MEDICAL,USA ONLY |
196M/838 |
100MHZ SCOPEMETER MEDICAL AMERICA - Discontinued - no replacement |
199/003 |
ScopeMeter - Discontinued - no replacement |
199/003S |
ScopeMeter - Discontinued - no replacement |
199B/3 |
SCOPEMETER 200MHZ B/W USA |
199B/3S |
SCOPEMETER 200MHZ B/W SCC USA - Discontinued - replaced by Fluke 199C/3S |
199BM |
SCOPEMETER 200 MHZ B/W MEDICAL UNIVERSAL - Discontinued - replaced byFluke 199BM/3 |
199BM/3 |
SCOPEMETER 200 MHZ B/W MEDICAL,USA ONLY - Discontinued - no replacement |
199C/3 |
SCOPEMETER 200MHZ COLOR USA |
199C/3-Refurb |
-Refurb Model SOLD OUT SCOPEMETER 200MHZ COLOR USA - Discontinued - replaced by Fluke 199C/3 |
199C/3S |
SCOPEMETER 200MHZ COLOR SCC USA |
199C/3S-Refurb |
-Refurb Model SOLD OUT SCOPEMETER 200MHZ COLOR SCC USA -Discontinued - replaced by Fluke 199C/3S |
199CM |
SCOPEMETER 200 MHZ COLOR MEDICAL UNIVERSAL - Discontinued - replaced by Fluke 199CM/3 |
199CM/3 |
SCOPEMETER 200 MHZ COLOR MEDICAL,USA ONLY |
199M/838 |
200MHZ SCOPEMETER MEDIACL AMERICA - Discontinued - no replacement |
1AC - A1 |
ACV DETECTOR,90-600V, ENGL/SPAN/ FRENCH - Discontinued - suggested replacement: Santronics AC-EZ or Fluke 1AC-A1-II |
1AC - A1R |
RACECAR EDITION, ACV DETECTOR,90-600V - Discontinued - suggested replacement: Santronics AC-EZ or Fluke 1AC-A1-II |
1AC-1 |
1AC-I Voltage Detector - Discontinued - replaced by Fluke 1AC-A1-II |
1AC-A1-1-5PK |
VOLT ALERT, 5 PACK, ENG, C. FRN, L.A. SPN |
1AC-A1-5PK |
Replaced by FLK-1AC-A1-II-5PK - Discontinued - replaced by Fluke 1AC-A1-II-5PK |
1AC-A1-I |
ACV DETECTOR 90-1000V - Discontinued - no replacement |
1AC-A1-I/CT |
COUNTER TOP, ACV DETECTOR 90-1000V - Discontinued - no replacement |
1AC-A1-II |
ACV DETECTOR 90-1000V, ENG, L.A. SPN, C. FRN |
1AC-A1-II-5PK |
VOLT ALERT, 5 PACK, ENG, C. FRN, L.A. SPN |
1AC-I |
1AC-I Voltage Detector - Discontinued - replaced by Fluke 1AC-A1-II |
1LAC - A |
LOW VOLTAGE DETECTOR AMERICAS PACIFIC - Discontinued - suggested replacement: Santronics LAC-EZ or Fluke 1LAC-A-II |
1LAC-A-II |
LOW VOLTAGE DETECTOR 20-90 VAC, ENG, C. FRN, L.A. SPN |
21 - 3 |
MULTIMETER, 600V CAT III, ELECTRICAL - Discontinued - replaced by Fluke 175 |
2142662 |
Replacement Battery for Fluke 1550B |
2156/RPM |
ETHERNET COMM CABLE KIT FOR STD ENCLOSURES - Discontinued - no replacement |
215C/003 |
SCOPEMETER 100 MHZ BUS HT NORTHAM. |
215C/003S |
SCOPEMETER 100 MHZ BUS HT NORTHAM. SCC |
225C/003 |
SCOPEMETER 200 MHZ BUS HT NORTHAM. |
225C/003S |
SCOPEMETER 200 MHZ BUS HT NORTHAM. SCC |
23 - 3 |
MULTIMETER, 1000V CAT II, ELECTRICAL - Discontinued - replaced by Fluke 177 |
233 |
Wireless Remote Display Digital Multimeter |
|
*FREE IWH C-66 CASE* |
26 - 3 |
TRUE RMS MULTIMETER, ELECTRICAL - Discontinued - replaced by Fluke 179 |
27 YEL |
MULTIMETER, YELLOW COLOR - Discontinued - replaced by Fluke 27II |
271-U 115V |
10MHZ DDS FUNCTION GENERATOR |
27B W/SV225 |
FLUKE-27 YEL,W/STRAY VOLTAGE ADAPTER MODULE - Discontinued - no replacement |
27II |
AVG MULTIMETER |
281-U 115V |
40MS/S UNIVERSAL WAVEFORM GENERATOR |
282-U 115V |
40MS/S 2CH UNIVERSAL WAVEFORM GENERATOR |
284-U 115V |
40MS/S 4CH UNIVERSAL WAVEFORM GENERATOR |
287 |
TRUE-RMS ELECTRONIC LOGGING MULTIMETER WITH TRENDCAPTURE |
|
*FREE IWH C-66 CASE* |
287/FVF |
TRUE-RMS ELECTRONIC LOGGING DMM W/TRENDCAPTURE, FLUKEVIEW S/W |
289 |
TRUE-RMS INDUSTRIAL LOGGING MULTIMETER WITH TRENDCAPTURE |
|
*FREE IWH C-66 CASE* |
289/FVF |
TRUE-RMS INDUSTRIAL LOGGING DMM W/TRENDCAPTURE, FLUKEVIEW S/W |
289/IMSK |
INDUSTRIAL MULTIMETER SERVICE KIT |
289/IMSK+ |
INDUSTRIAL MULTIMETER SERVICE KIT with IWH-C66 Case |
28II |
TRMS MULTIMETER |
291-U 115V |
100MS/S ARBITRARY WAVEFORM GENERATOR |
292-U 115V |
100MS/S 2CH ARBITRARY WAVEFORM GENERATOR |
294-U 115V |
100MS/S 4CH ARBITRARY WAVEFORM GENERATOR |
2AC/90-1000V |
ACV DETECTOR 90-1000V, ENG, C. FRN, SPN |
2AC/90-1000V5PK |
VOLT ALERT 90-1000V, 5 PACK, ENG, C. FRN, SPN |
30 |
CLAMP METER W/AC AMPS, VOLTS AND OHMS - Discontinued - replaced by Fluke 373 |
3000/6000A FLEX 4 |
3000A/6000A 36-INCH FLEXI PROBE 4 PHASE |
3005-PR |
5 AMP, CLAMP WITH 10 FT. EXTENDER CABLE |
3005R |
RPM, 5 AMP CLAMP W/3570 CT CABLE - Discontinued - no replacement |
3014-PR |
40 AMP, CLAMP WITH 10 FT. EXTENDER CABLE |
3014R |
RPM, 40 AMP CLAMP - Discontinued - no replacement |
31 |
TRUE RMS CLAMP METER - Discontinued - replaced by Fluke 322 |
3100R |
RPM, 1000 AMP CLAMP - Discontinued - no replacement |
3110/RPM |
24-000-3110, 100 AMP FLEX CT 24 IN - Discontinued - no replacement |
3110-PR |
100 AMP, FLEX CT 24 IN |
3112/RPM |
24-000-3112, 100 AMP FLEX CT 48 IN - Discontinued - no replacement |
3120R |
RPM, 200 AMP CURRENT CLAMP - Discontinued - replaced by Fluke 3140R |
3140R |
CURRENT CLAMP, 400 AMP |
32 |
TRMS CLAMP METER,AC AMPS VOLTS & OHMS - Discontinued - replaced by Fluke 335A |
321 |
400AMP, AC CLAMP METER; MIDSIZE JAW |
3210/RPM |
25-000-3210, 1000 AMP FLEX CT 24 IN - Discontinued - no replacement |
3210-PR |
1000 AMP, FLEX CT 24 IN |
3212/RPM |
25-000-3212, 1000 AMP FLEX CT 48 IN - Discontinued - replaced by Fluke 3210-PR |
322 |
400AMP, 40AMP,AC CLAMP METER; MIDSIZE JAW |
33 |
TRUE RMS CLAMP METER - Discontinued - replaced by Fluke 353 |
3300R |
RPM, 25-000-3300, 3000 AMP CLAMP - Discontinued - no replacement |
3310/RPM |
25-000-3310, 5000 AMP FLEX CT 24 IN - Discontinued - replaced by Fluke 3310-PR |
3310-PR |
5000 AMP, FLEX CT 24 IN |
3312/RPM |
25-000-3312, 5000 AMP FLEX CT 48 IN - Discontinued - replaced by Fluke 3312-PR |
3312-PR |
5000 AMP, FLEX CT 48 IN |
333 |
400 Amp Ac Digital Clamp Meter - Discontinued - replaced by Fluke 373 |
333A |
FLUKE-333A,400 AMP AC DIGITAL CLAMP METER - Discontinued - replaced byFluke 373 |
334 |
600 Amp Ac Digital Clamp Meter With Backlight - Discontinued - replaced by Fluke 373 |
334A |
FLUKE-334A,600 AMP AC DIGITAL CLAMP METER WITH BACKLIGHT -Discontinued - replaced by Fluke 373 |
335 |
600 Amp True Rms Ac Digital Clamp Meter With Backlight - Discontinued - replaced by Fluke 373 or Fluke 374 |
335A |
*Clearance* FLUKE-335A,600 AMP TRUE RMS AC DIGITAL CLAMP METER WITH BACKLIGHT |
336 |
600 Amp True Rms Ac/Dc Digital Clamp Meter With Backlight - Discontinued - replaced by Fluke 375 |
336A |
FLUKE-336A,600 AMP TRUE RMS AC/DC DIGITAL CLAMP METER WITH BACKLIGHT - Discontinued - replaced by Fluke 375 |
337 |
1000 Amp True Rms Ac/Dc Digital Clamp Meter With Backlight - Discontinued - replaced by Fluke 376 or Fluke 381 |
337A |
FLUKE-337A,1000 AMP TRUE RMS AC/DC DIGITAL CLAMP METER WITH BACKLIGHT - Discontinued - replaced by Fluke 376 or Fluke 381 |
337A-FB |
FLUKE-337A,1000 AMP TRUE RMS AC/DC DIGITAL CLAMP METER WITH BACKLIGHT Includes FREE Football! |
337-FB |
1000 Amp True Rms Ac/Dc Digital Clamp Meter With FREE Football - Discontinued- replaced by Fluke 376 or Fluke 381 |
345 |
POWER QUALITY CLAMP METER |
353 |
AC/DC TRMS CLAMP METER,2000A,AMPS ONLY |
3533/RPM |
PAS POD ADAPTER FOR FLEX CT - Discontinued - no replacement |
355 |
AC/DC TRMS CLAMP METER,2000A |
3570/RPM |
CT CABLE, 10 FT, AEMC TO PR INTERFACE - Discontinued - no replacement |
3570/RPM-12 |
CT CABLE, 12FT, AEMC TO PR INTERFACE - Discontinued - no replacement |
3570/RPM-40 |
CT CABLE, 40FT, AEMC TO PR INTERFACE - Discontinued - no replacement |
3570-PR |
CT CABLE, 10 FT, AEMC TO PR INTERFACE |
3577/RPM-20 |
CT CABLE, 20FT, AEMC TO PR INTERFACE - Discontinued - no replacement |
3583R |
RPM, 10 AMP SPLIT CORE CT W/INTERFACE CABLE - Discontinued - suggested replacement: NK ATP1-420-120-FF |
3584R |
RPM, 40 AMP SPLIT CORE CT W/INTERFACE CABLE - Discontinued - suggested replacement: NK ATP1-420-120-FF |
3585R |
RPM, 100 AMP SPLIT CORE CT W/INTERFACE CABLE - Discontinued - suggested replacement: NK ATP1-420-120-FF |
36 |
ACDC CLAMP METER,TRMS,AMPS,VOLTS,OHMS - Discontinued - replaced byFluke 375 |
360 |
LEAKAGE CURRENT CLAMP METER |
3601/RPM |
CROCODILE TYPE VOLTAGE PROBE, SET OF 5 CLIPS - Discontinued - no replacement |
3602/RPM |
BATTERY TYPE VOLTAGE PROBE, SET OF 5 CLIPS - Discontinued - no replacement |
3605/RPM |
SYRINGE STUD TYPE VOLTAGE PROBES, 5 PROBES - Discontinued - no replacement |
3606/RPM |
THREADED STUD TYPE VOLTAGE PROBE, 5 PROBES - Discontinued - no replacement |
3607/RPM |
SIDE CLAMP VOLTAGE F-TYPE PROBE,SET OF 5 - Discontinued - no replacement |
3608/RPM |
PLUNGER TYPE VOLTAGE PROBE, 5 SYRINGE-ACTION - Discontinued - no replacement |
3641/RPM |
FUSES, IN LINE SET OF 5 - Discontinued - no replacement |
365 |
DETACHABLE 200A TRMS AC/DC CLAMP |
373 |
600A TRMS AC CLAMP METER |
374 |
600A TRMS AC/DC CLAMP |
375 |
600A TRMS AC/DC CLAMP |
376 |
1000A TRMS AC/DC CLAMP W/IFLEX |
381 |
REMOTE DISP 1000A TRMS CLAMP W/IFLEX |
39 |
POWER METER, ENGL MANUL - Discontinued - replaced by Fluke 43B/003 |
4001 |
RPM, CARRY BAG, W/RPM LOGO |
4003 |
RPM, SHIPPING CADDY WITH WHEELS |
4005 |
RPM, SHIPPING CONTAINER, REUSABLE |
4006 |
RPM, SECURITY CBL, STEEL, 6 FT LOOPED LOCKABLE |
4008 |
RPM, MONITOR BRACKETS - Discontinued - no replacement |
41 UGK |
FLUKEVIEW FOR WINDOWS LOGGING UGK,V3.2 |
410D |
*Clearance* 100 ft Laser Distance Meter |
|
Compare to Fluke 411D |
411D |
LASER DISTANCE METER, 30M/100FT MAX. |
411D/62 |
411D LASER DISTANCE METER AND 62 IR THERMOMETER |
415D |
200 ft Laser Distance Meter |
|
Compare to Fluke 416D - Discontinued - replaced by Fluke 416D |
416D |
LASER DISTANCE METER, 60M/200FT MAX. |
41B |
POWER HARMONICS ANALYZER, ENGL MANUAL - Discontinued - replaced byFluke 43B/003 |
421D |
LASER DISTANCE METER, 100 METER |
43/03 |
POWER QUALITY ANALYZER USA VERSION - Discontinued - replaced by Fluke 43B/003 |
433/003 |
Power Quality Analyzer 3 Phase America - Discontinued - replaced by Fluke 434/003 |
433/UGK |
UPGRADE ADV FUNC SW CABLE - Discontinued - no replacement |
434/003 |
POWER QUALITY ANALYZER 3 PHASE |
434/003-Refurb |
POWER QUALITY ANALYZER 3 PHASE (Refurbished) - Discontinued - no replacement |
434/BASIC |
POWER QUALITY ANALYZER 3 PHASE, W/O CURRENT PROBES |
434/LOG |
FIRMWARE/SOFTWARE UPGRADE FOR FLUKE-434 |
435/003 |
POWER QUALITY ANALYZER 3 PHASE AMERICA |
435/003-Refurb |
-Refurb Model SOLD OUT POWER QUALITY ANALYZER 3 PHASE AMERICA -Discontinued - replaced by Fluke 435/003 |
435/BASIC |
POWER QUALITY ANALYZER 3 PHASE, W/O CURRENT PROBES |
43B/003 |
POWER QUALITY ANALYZER, USA |
43B/003-Refurb |
Factory Refurbished, Like New!!! Full Warranty POWER QUALITY ANALYZER, USA - Discontinued - no replacement |
45 |
Digital Multimeter - Discontinued - replaced by Fluke 8845A 120V |
45-01 |
Digital Multimeter W/Batteries - Discontinued - replaced by Fluke 8845A 120V |
45-01K |
Battery Pack Kit - Discontinued - no replacement |
45-05 |
Digital Multimeter W/ IEEE - Discontinued - replaced by Fluke 8845A 120V |
45-05K |
IEEE KIT - Discontinued - no replacement |
45-15 |
igital Multimeter W/Batteries/IEEE - Discontinued - replaced by Fluke 8845A 120V |
5000S/RPM |
POWER ANALYSIS SYSTEM SOFTWARE |
5020A-CASE |
Case, Carrying, 5020A-X - Discontinued - no replacement |
5020A-LW3 |
Software, Application (Single-Pc License) - Discontinued - no replacement |
5020A-LWLIC |
License, Application (For Additional Pcs) - Discontinued - no replacement |
5020A-PS |
Power Supply, Spare, Universal, 110/230 - Discontinued - no replacement |
5020A-S |
Fluke Thermo-Hygrometer, Standard - Discontinued - no replacement |
5020A-S KIT |
Fluke Thermo-Hygrometer, Std Accuracy Val Kit - Discontinued - no replacement |
5026A-CASE |
Case, Spare Probe, 5026A-H/5026A-S - Discontinued - no replacement |
5026A-S |
Probe, Thermo-Hygrometer Spare, 5020A-S - Discontinued - no replacement |
5027A-S |
Kit,Thermo-Hygrometer Spare Probe,5020A-S - Discontinued - no replacement |
5030A-MNT |
Bracket, Wall Mount, For 5026A-X Probe - Discontinued - no replacement |
5032A-64MB |
Card, Pcmcia, 64Mb - Discontinued - no replacement |
50D |
Dual Input Thermometer - Discontinued - replaced by Fluke 52-2 60HZ |
50S |
Single Input Thermometer - Discontinued - replaced by Fluke 51-2 60HZ |
5100S/RPM |
POWER ANALYSIS SYSTEM SOFTWARE WITH REPORT WRITER |
51-2 60HZ |
SINGLE INPUT THERMOMETER, 60HZ NOISE REJECTION |
52-2 60HZ |
DUAL INPUT THERMOMETER, 60HZ NOISE REJECTION |
53-2 60HZ |
SINGLE INPUT THERMOMETER W/RECORDING, 60HZ NOISE REJECTION |
5400/RPM |
SOFTWARE, SCENARIO |
54-2 60HZ |
DUAL INPUT THERMOMETER W/RECORDING, 60HZ NOISE REJECTION |
|
|
|
|
5500S/RPM |
POWER ANALYSIS SYSTEM SOFTWARE WITH MASTER POLLING |
5600S/RPM |
PWR ANALYSIS SYS SW W/RPT WTR, MASTER POLLING |
561 |
HVACPRO IR THERMOMETER |
566 |
IR THERMOMETER |
568 |
IR THERMOMETER |
572 |
PRECISION IR THERMOMETER |
572-CF |
PRECISION IR THERMOMETER W/CLOSE FOCUS |
574 |
PRECISON IR THERMOMETER W/LOGGING SW |
574-CF |
PRECISON IR THERM W/LOGGING SW CLOSE FOCUS |
574-NI |
PRECISION IR THERM W/LOGGING SW NONINCENDIVE |
576 |
PRECISION PHOTOGRAPHIC IR THERM W/LOGGING SW - Discontinued - no replacement |
576-CF |
PREC PHOTO IR THERM W/LOGGING SW CLOSE FOCUS - Discontinued - no replacement |
5900/RPM |
SOFTWARE, SYSTEM UPGRADE DISK W/MANUAL |
5901/RPM |
S/W UPGRADE, ADDS REPORT WRITER TO POWER ANALYSIS S/W |
5903/RPM |
S/W UPGRADE, ADDS MASTER POLLING TO POWER ANALYSIS S/W |
5904/RPM |
S/W UPGRADE, ADDS SUB-POLLING TO POWER ANALYSIS S/W |
5905/RPM |
S/W UPGRADE, ADDS RW & POLLING TO POWER ANALYSIS S/W |
6062A |
DIGITAL MULTIMETER, 4 1/2 DIGITS |
609096 |
VIDEO, UNDERSTAND / MANAGEG HARMONICS |
61 |
IR THERMOMETER |
62 |
MINI IR THERMOMETER |
62/322/1AC |
KIT WITH FLUKE-62/322/1AC |
62/T+PRO/1AC |
KIT WITH C115 SOFTCASE |
620 |
LAN CableMeter - Discontinued - suggested replacement: AEMC 2127.81 |
62S |
MINI IR THERMOMETER SINGLE UNIT |
63 |
INFRARED THERMOMETER TO 535C (999F) |
648029 |
Red and Black Test Leads without tip for T5-600 |
65 AMER |
INFRARED THERMOMETER - Discontinued - replaced by Fluke 62 |
66 |
ADJUSTABLE INFRARED THERMOMETER |
68 |
ADJUSTABLE INFRARED THERMOMETER |
68IS |
INTRIN SAFE(FM)IR THERMOMETER W/RTD PROBE |
700BCA |
BAR CODE ADAPTER |
700BCW |
BAR CODE WAND |
700HTH |
HYDRAULIC TEST HOSE,10,000 PSI/ 700 BAR WORKING PRESSURE -Discontinued - replaced by Fluke 700HTH-1 |
700HTH-1 |
HYDRAULIC TEST HOSE, 10,000 PSI/690 BAR |
700HTP |
HYDRAULIC TEST PUMP - Discontinued - replaced by Fluke 700HTP-1 |
700HTP-1 |
HYDRAULIC TEST PUMP, 10,000 PSI/700 BAR |
700ILF |
IN-LINE FILTER,1 MICRON,100 PSI |
700-IV |
CURRENT SHUNT |
700LTP |
LOW-PRESSURE TEST PUMP FOR PRESSURES 30 PSI/ 2 BAR - Discontinued - replaced by Fluke 700LTP-1 |
700LTP-1 |
LOW-PRESSURE TEST PUMP, 100 PSI/7 BAR |
700P00 |
PRESSURE MODULE, 0-1 IN. H20 DIFF |
700P01 |
PRESSURE MODULE, 0-10 IN. H20 DIFF |
700P01EX |
I.S. PRESSURE MODULE, 0-10 IN. H20 DIFF |
700P02 |
PRESSURE MODULE, 0-1 PSID |
700P03 |
PRESSURE MODULE, 0-5 PSID |
700P04 |
PRESSURE MODULE, 0-15 PSID |
700P05 |
PRESSURE MODULE, 0-30 PSIG |
700P05EX |
I.S. PRESSURE MODULE, 0-30 PSIG |
700P06 |
PRESSURE MODULE, 0-100 PSIG |
700P06EX |
I.S. PRESSURE MODULE, 0-100 PSIG |
700P07 |
PRESSURE MODULE, 0-500 PSIG |
700P08 |
PRESSURE MODULE, 0-1000 PSIG |
700P09 |
PRESSURE MODULE 1500PSIG |
700P09EX |
I.S. PRESSURE MODULE 1500 PSIG |
700P22 |
PRESSURE MODULE, 0-1 PSID, WET |
700P23 |
PRESSURE MODULE, 0-5 PSID, WET |
700P24 |
PRESSURE MODULE, 0-15 PSID, WET |
700P24EX |
I.S. PRESSURE MODULE, 0-15 PSID, WET |
700P27 |
PRESSURE MODULE, 300 PSIG |
700P27EX |
I.S. PRESSURE MODULE, 300 PSIG |
700P29 |
PRESSURE MODULE,3000PSIG WET |
700P29EX |
I.S. PRESSURE MODULE,3000PSIG WET |
700P30 |
PRESSURE MODULE,5000PSIG WET |
700P31 |
PRESSURE MODULE,10000PSIG WET |
700PA3 |
PRESSURE MODULE 0-5PSIA |
700PA4 |
PRESSURE MODULE 0-15PSIA |
700PA4EX |
I.S. PRESSURE MODULE 0-15 PSIA |
700PA5 |
PRESSURE MODULE 0-30PSIA |
700PA6 |
PRESSURE MODULE 0-100PSIA |
700PCK |
PRESSURE MODULE CALIBRATION KIT |
700PD2 |
PRESSURE MODULE +/-1 PSID |
700PD3 |
PRESSURE MODULE +/-5 PSID |
700PD4 |
PRESSURE MODULE, +/-15PSID |
700PD5 |
PRESSURE MODULE -15+30 PSIG |
700PD6 |
PRESSURE MODULE -15+100PSIG |
700PD7 |
PRESSURE MODULE -15+200PSIG |
700PMP |
PRESSURE PUMP |
700PRV |
PRESSURE RELIEF VALVE KIT - Discontinued - replaced by Fluke 700PRV-1 |
700PRV-1 |
PRESSURE RELIEF VALVE KIT |
700PTP |
PNEUMATIC TEST PUMP - Discontinued - replaced by Fluke 700PTP-1 |
700PTP-1 |
PNEUMATIC TEST PUMP. -13 TO 600 PSI |
700PV3 |
PRESSURE MODULE -5PSID |
700PV4 |
PRESSURE MODULE -15PSID |
700RTD |
PRECISION RTD; BANANA JACKS |
700SC |
CABLE ASSEMBLY, SERIAL INTERFACE |
700SW |
DPC/TRACK |
700TC1 |
TC MINI-PLUG KIT (TEN TYPES) |
700TC2 |
T/C MINI-PLUG KIT TYPE J,K,T,E,R,S |
70-3 |
MULTIMETER,600V CAT II, INDUSTRIAL - Discontinued - replaced by Fluke 115 |
705 |
LOOP CALIBRATOR |
707 |
LOOP CALIBRATOR |
707EX |
MA CALIBRATOR |
712 |
RTD CALIBRATOR |
713 100G |
PRESSURE CALIBRATOR, 100 PSIG - Discontinued - replaced by Fluke 717 100G |
713 30G |
PRESSURE CALIBRATOR, 30 PSIG - Discontinued - replaced by Fluke 717 30G |
714 |
THERMOCOUPLE CALIBRATOR |
715 |
VOLT/MA CALIBRATOR |
716 |
PRESSURE CALIBRATOR - Discontinued - replaced by Fluke 717 30G |
717 1000G |
PRESSURE CALIBRATOR 1000 PSIG |
717 100G |
PRESSURE CALIBRATOR, 100 PSIG |
717 1500G |
PRESSURE CALIBRATOR 1500 PSIG |
717 1G |
PRESSURE CALIBRATOR 1 PSIG |
717 3000G |
PRESSURE CALIBRATOR 3000 PSIG |
717 300G |
PRESSURE CALIBRATOR 300 PSIG |
717 30G |
PRESSURE CALIBRATOR, 30 PSIG |
717 5000G |
PRESSURE CALIBRATOR 5000 PSIG |
717 500G |
PRESSURE CALIBRATOR 500 PSIG |
718 100 |
PRESSURE CALIBRATOR 100 PSIG USA |
718 100G |
PRESSURE CALIBRATOR 100 PSIG USA |
718 100US |
PRESSURE CALIBRATOR 100 PSIG USA |
718 1G |
PRESSURE CALIBRATOR 1 PSIG |
718 30 |
PRESSURE CALIBRATOR 30 PSIG USA |
718 300G |
PRESSURE CALIBRATOR 300 PSIG |
718 30G |
PRESSURE CALIBRATOR 30 PSIG USA |
718 30US |
PRESSURE CALIBRATOR 30 PSIG USA |
718EX 100 |
I.S. PRESSURE CALIBRATOR 100 PSIG |
718EX 30 |
I.S. PRESSURE CALIBRATOR 30 PSIG |
718EX 300 |
I.S. PRESSURE CALIBRATOR 300 PSIG |
719 100G |
ELECTRIC PRESSURE CALIBRATOR, 100 PSI, 7 BAR |
719 30G |
ELECTRIC PRESSURE CALIBRATOR, 30 PSI, 2 BAR |
71X |
HOSE KIT ACCESSORY |
724 |
TEMPERATURE CALIBRATOR |
725 US |
MULTIFUNCTION PROCESS CALIBRATOR |
725/P27EX |
I.S. PROCESS CALIBRATOR AND 300 PSI PRESSURE MODULE Must order min. 10 each |
725EX |
I.S. MULTIFUNCTION PROCESS CALIBRATOR |
726 |
PRECISION MULTIFUNCTION CALIBRATOR |
7-300 |
ELECTRICAL TESTER - Discontinued - replaced by Fluke 114 |
73-3 |
Multimeter, 600V Cat Ii, Industrial - Discontinued - replaced by Fluke 77-4 or Fluke 179 or Fluke 117 |
741B 120 |
DOCUMENTING PROCESS CALIBRATOR |
743B 120 |
DOCUMENTING PROCESS CALIBRATOR |
744 120 |
DOCUMENTING PROCESS CALIBRATOR |
744V20 |
HART UPGRADE |
744V2V |
HART UPGRADE 5-PACK |
75-3 |
MULTIMETER, 600V CAT III, INDUSTRIAL - Discontinued - replaced by Fluke 175 |
7-600 |
ELECTRICAL TESTER - Discontinued - replaced by Fluke 114 |
771 |
MILLIAMP PROCESS CLAMP METER |
772 |
MILLIAMP PROCESS CLAMP METER |
773 |
MILLIAMP PROCESS CLAMP METER |
77-3 |
Multimeter, 1000V Cat Ii, Industrial - Discontinued - replaced by Fluke 77-4 |
77-4 |
INDUSTRIAL MULTIMETER, 1000V CAT III |
|
*FREE IWH C-66 CASE* |
78 |
Automotive,Meter W/Rpm,Dwell,Temp - Discontinued - replaced by Fluke 88-5 |
787 |
PROCESSMETER |
|
*FREE IWH C-66 CASE* |
787CAL120 |
CALIBRATION MODULE, US |
789 |
PROCESSMETER |
|
*FREE IWH C-66 CASE* |
789/TEC |
ProcessMeter & Thermocouple Kit |
79-3 |
TRUS RMS MULTIMETER, INDUSTRIAL - Discontinued - replaced by Fluke 179 |
800919 |
VIDEO,PQ TROUBLESHOOTING,NTSC |
8060A |
DIGITAL MULTIMETER, 4 1/2 DIGITS - Discontinued - replaced by Fluke 289 |
8062A |
Digital Multimeter, 4.5 Digits - Discontinued - replaced by Fluke 289 |
80AK |
Thermocouple Adapter Accessory - Discontinued - replaced by Fluke 80AK-A |
80AK-A |
TYPE K, THERMOCOUPLE ADAPTER |
80BK |
Type K Integrated Dmm Probe - Discontinued - replaced by Fluke 80BK-A |
80BK-A |
TYPE K, INTEGRATED DMM PROBE |
80CJ-M |
MINI THERMOCOUPLE CONNECT,TYPE J,MALE |
80CK-M |
MINI THERMOCOUPLE CONNECT,TYPE K,MALE |
80I-1000S |
AC CURRENT OSCILLOSCOPE PROBE - Discontinued - replaced by Fluke I1000S |
80I-110S |
AC/DC CURRENT PROBE, SCOPEMETER(R) |
80I-400 |
PROBE, CURRENT. 400 AMPS. - Discontinued - replaced by Fluke I400 |
80I-500S |
AC CUR PROBE, OSCILLOSCOPE, 500 AMPS - Discontinued - replaced by Fluke I400S |
80I-600A |
CURRENT PROBE ASSEMBLY Available thru 10/15/07 only - Discontinued - replaced by Fluke I800 |
80K-15 |
PROBE, ELECTRONIC AIR CLEANER |
80K-40 |
PROBE, HIGH VOLTAGE* |
80K-6 |
PROBE, HIGH VOLTAGE* |
80PJ-1 |
TYPE J BEAD PROBE,THERMOCOUPLE ASSEMBLY,TYPE J,BEADED,TYPE J,48 IN,BULK |
80PJ-9 |
TYPE J LANCE TIP PROBE,THERMOCOUPLE ASSEMBLY,TYPE J,LANCE TIP PROBE,MOLDED PLUG,1M,BULK |
80PJ-EXT |
TYPE J EXTENSION KIT, THERMOCOUPLE ASSEMBLY, 3 METERS |
80PK-1 |
PROBE, THERMOCOUPLE, BEADED K-TYPE |
80PK-10 |
TYPE-K, PIPE CLAMP THERMOCOUPLE PROBE, 1.25-2.5 |
80PK-11 |
K-TYPE VELCRO TEMPERATURE PROBE |
80PK-18 |
TYPE K PIPE CLAMP THERMOCOUPLE PROBE KIT, 0-2.5 |
80PK-22 |
SUREGRIP, IMMERSION TEMPERATURE PROBE |
80PK-24 |
SUREGRIP, AIR TEMPERATURE PROBE |
80PK-25 |
SUREGRIP, PIERCING TEMPERATURE PROBE |
80PK-26 |
SUREGRIP, TAPERED TEMPERATURE PROBE |
80PK-27 |
SUREGRIP, INDUSTRIAL SURFACE TEMPERATURE PROBE |
80PK-2A |
PROBE, THERMOCOUPLE, IMMERSION, K-TYPE - Discontinued - replaced byFluke 80PK-22 |
80PK-3A |
PROBE,SURFACE |
80PK-4A |
PROBE, THERMOCOUPLE, AIR, K-TYPE - Discontinued - replaced by Fluke 80PK-24 |
80PK-5A |
PROBE, PIERCING - Discontinued - replaced by Fluke 80PK-25 |
80PK-6A |
PROBE, THERMOCOUPLE, EXPOSED, K-TYPE - Discontinued - replaced by Fluke 80PK-26 |
80PK-7 |
PROBE, THERMOCOUPLE, RUGGEDIZED, K-TYPE - Discontinued - replaced byFluke 80PK-27 |
80PK-8 |
TYPE-K, PIPE CLAMP THERMOCOUPLE PROBE |
80PK-9 |
TYPE K LANCE TIP PROBE,THERMOCOUPLE ASSEMBLY,TYPE K,LANCE TIP PROBE,MOLDED PLUG,1M,BULK |
80PK-EXT |
TYPE K EXTENSION KIT, THERMOCOUPLE ASSEMBLY, 3 METERS |
80PK-IR |
INFRARED THERMOCOUPLE PROBE (TYPE-K) - Discontinued - no replacement |
80PR-60 |
IR-PISTOL-RTD PROBE |
80PT-25 |
SUREGRIP, PIERCING TEMPERATURE PROBE |
80PT-5A |
TYPE T PIERCING PROBE, THERMOCOUPLE ASSEMBLY, MOLDED PLUG, 48 IN , BULK - Discontinued - replaced by Fluke 80PT-25 |
80PT-EXT |
TYPE T EXTENSION KIT, THERMOCOUPLE ASSEMBLY, 3 METERS |
80T-150U |
PROBE, TEMPERATURE - Discontinued - replaced by Fluke 80T-150UA |
80T-150UA |
PROBE,TEMPERATURE |
80T-IR |
INFRARED THERMOMETER PROBE - Discontinued - no replacement |
80T-IR/E |
INFRARED THERM PROBE, EXTND RNGE, DEG F - Discontinued - replaced byFluke 80T-IR |
80TK |
THERMOCOUPLE MODULE |
810 |
Vibration Tester |
83-3 USA |
MULTIMETER - Discontinued - replaced by Fluke 83-5 |
83-5 |
INDUSTRIAL MULTIMETER |
|
*FREE IWH C-66 CASE* |
8508A |
Fluke 8508A - Discontinued - no replacement |
85-3 USA |
TRUE RMS MULTIMETER - Discontinued - replaced by Fluke 87-5 |
85RF |
HIGH FREQUENCY PROBE, 500 MHZ |
867BE 120 |
4.5 DIGIT GRAPHICAL MULTIMETER - Discontinued - replaced by Fluke 123/3 orFluke 289 |
87-3 USA |
TRUE RMS MULTIMETER - Discontinued - replaced by Fluke 87-5 |
87-5 |
INDUSTRIAL TRUE RMS MULTIMETER |
|
*FREE IWH C-66 CASE* |
87-5/E KIT |
Fluke-87V/E Kit INDUSTRIAL TRUE RMS MULTIMETER COMBO KIT - Discontinued- replaced by Fluke 87-5/E2 KIT |
87-5/E2 KIT |
INDUSTRIAL TRUE-RMS MULTIMETER COMBO KIT |
87-5-EX |
INTRINSICALLY SAFE TRUE RMS MULTIMETER |
87-5-EX-KIT |
Ecom 87V Multimeter Pack - Discontinued - no replacement |
87-5-EX-Refurb |
-Refurb Model SOLD OUT INTRINSICALLY SAFE TRUE RMS MULTIMETER -Discontinued - replaced by Fluke 87-5-EX |
87E-3USA |
TRUE RMS MULTIMETER-ELECTRICAL (US) - replaced by Fluke 87V/E -Discontinued - no replacement |
87E-3USA |
TRUE RMS MULTIMETER-ELECTRICAL (US) - replaced by Fluke 87V/E -Discontinued - no replacement |
87-RETROFIT |
RETROFIT KIT FOR FLUKE 83,85,87-3,787 METERS |
87V/AEK |
FLUKE-87V DMM, TL81A TEST LEADS & C115 SOFT CASE - Discontinued - suggested replacement: IWH C-66 |
87V/IMSK |
INDUSTRIAL MULTIMETER SERVICE KIT |
87V/IMSK+ |
INDUSTRIAL MULTIMETER SERVICE KIT with IWH-C66 Case |
88 |
AUTOMOTIVE METER - Discontinued - replaced by Fluke 88-5 or Fluke 88-5/A KIT |
8808A 120V |
5.5 DIGIT PRECISION MULTIMETER |
8808A/SU 120V |
5.5 DIGIT PRECISION MULTIMETER, SW & CABLE |
8845A 120V |
6.5 DIGIT PRECISION MULTIMETER, 35PPM |
8845A/SU 120V |
6.5 DIGIT PRECISION MULTIMETER, SW & CABLE |
8845A-EFPT |
EXTENDED FINE PT TIP ADAP SET (SET RED/BLACK) |
8845A-TPIT |
TEST PROBE IC TIP (SET RED & BLACK) |
8846A 120V |
6.5 DIGIT PRECISION MULTIMETER, 24PPM USBMEM |
8846A/SU 120V |
6.5 DIGIT PRECISION MULTIMETER, SW & CABLE |
884X-1G |
USB MEMORY 1 GB |
884X-512M |
USB MEMORY 512M |
884X-CASE |
HEAVY DUTY BLACK CASE |
884X-ETH |
ETHERNET INTERFACE CABLE |
884X-RTD |
100 OHM RTD TEMPERATURE PROBE |
884X-SHORT |
4 WIRE SHORT |
884X-USB |
USB TO RS232 CABLE ADAPTER |
88-5 |
88V AUTOMOTIVE MULTIMETER |
|
*FREE IWH C-66 CASE* |
88-5/A KIT |
AUTOMOTIVE METER COMBO KIT |
902 |
TRUE RMS HVAC CLAMP METER |
|
*FREE IWH C-66 CASE* |
9040 |
PHASE SEQUENCE INDICATOR |
90I-610S |
AC/DC CURRENT PROBE |
922 |
AIRFLOW METER |
922/KIT |
AIRFLOW METER KIT |
971 |
TEMPERATURE HUMIDITY METER |
975 |
AIRMETER |
975B1 |
BOTTLE CALIBRATION GAS, 200 PPM CO, 5000 PPM CO2, BAL NITROGEN MUST DROP SHIP TO END USER |
975B2 |
BOTTLE CALIBRATION GAS, NITROGEN CO FREE, CO2 FREE MUST DROP SHIP TO END USER |
975CK |
AIR METER,CALIBRATION KIT MUST DROP SHIP TO END USER |
975V |
AIRMETER WITH VELOCITY PROBE |
975VP |
AIR VELOCITY PROBE |
983 |
PARTICLE COUNTER |
983TPK 120 |
PRINTER KIT, THERMAL, US 120V |
A3P 3PH 5/50A CTS |
Sx8350A, Analyst 3P Clamp Set 5A/50A 3-Ph - Discontinued - no replacement |
A3P 3PH FLEX |
Sx8315A, Analyst 3P Flex 3 Ph Set 5A/150A/3000A - Discontinued - no replacement |
A3P 4PH 5/50A CTS |
Sx8450A, Analyst 3P Clamp Set 5A/50A 3-Ph + N - Discontinued - no replacement |
A3P 4PH FLEX |
Sx8415A, Analyst 3P Flex 4 Ph Set 5A/150A/3000A - Discontinued - no replacement |
A40-10A |
Current Shunt: 10 AMP |
A460330506 |
Current Channel 61I1, 35-1100 Mvrms, D6X Series |
A460330508 |
Interface 61D2 Motor, Ieee488, 12 Analog |
A460330515 |
Voltage Channel 61U2 1.7-150 Vrms |
A460330520 |
I/F 61D4 Motor, Requires S/W Ver V7.2 |
A550500320 |
OPTION DIGITAL ALARM OUTPUTS |
A620296200 |
PAPER ROLL FOR D6000 THERMO PRINTER - Discontinued - no replacement |
A620380001 |
RIBBON CASSETTE FOR D6000 MATRIX PRINTER |
A641401000 |
ADAPTER 61IX TO BNC 1.5M - Discontinued - no replacement |
A641401001 |
TRIAXIAL-SHUNT 300MA (3MA...3A) - Discontinued - no replacement |
A641401003 |
Adapter 61Ix To Bnc 5M |
A641401004 |
ADAPTER 61IX TO LEMOSA, 1.5M - Discontinued - no replacement |
A641401005 |
Adapter 61Ix To Lemosa, 5M |
A641401006 |
ADAPTER 61IX TO BNC 1.5M W/IDENTIFICATION - Discontinued - no replacement |
A641401007 |
ADAPTER 61IX TO BNC 5M W/IDENTIFICATION - Discontinued - no replacement |
A641401008 |
ADAPTER 61IX TO LEMOSA 1.5M WITH IDENTIFICATION - Discontinued - no replacement |
A641401009 |
ADAPTER 61IX TO LEMOSA 5M WITH IDENTIFICATION - Discontinued - no replacement |
A641401010 |
TRIAXIAL-SHUNT 3A (30MA...10A) |
A641401013 |
EXTENSION CABLE TRIAXIAL 5M, W/LEMOSA PLUG |
A641401014 |
TRIAXIAL-SHUNT 1A (10MA...3A) |
A641401018 |
EXTENSION CABLE TRIAXIAL 1.6M, W/LEMOSA PLUG |
A641401022 |
ADAPTER 61IX WITH BNC SOCKET - Discontinued - no replacement |
A641401340 |
TRIAXIAL-SHUNT 300A (18A - 1000A) |
A641401350 |
TRIAXIAL SHUNT 500A (18A - 1500A) |
A641401355 |
TRIAXIAL SHUNT 150A (2A - 450A) |
A81 115 |
BATTERY CHARGER/ELIMINATOR - Discontinued - no replacement |
AC120 |
ALLIGATOR CLIP-SET |
AC20 |
SAFETY ALLIGATOR CLIPS - Discontinued - replaced by Fluke AC220 |
AC220 |
SUREGRIP ALLIGATOR CLIP |
AC280 |
SUREGRIP HOOK CLIPS |
AC283 |
SUREGRIP PINCER CLIPS |
AC285 |
SUREGRIP LARGE ALLIGATOR CLIP |
AC70A |
ALLIGATOR CLIP-SET - Discontinued - replaced by Fluke AC72 |
AC72 |
ALLIGATOR CLIP SET, 1000V |
AC80 |
HOOK-STYLE TEST CLIPS - Discontinued - replaced by Fluke AC280 |
AC83 |
PIN-GRABBER TEST CLIPS - Discontinued - replaced by Fluke AC283 |
AC85A |
LARGE JAW ALLIGATOR CLIPS - Discontinued - replaced by Fluke AC285 |
AC86 |
LARGE JAW ALLIGATOR CLIPS - Discontinued - replaced by Fluke AC285 |
AC87 |
TEST LEAD ACCESSORY BUS BAR CLIP |
AC89 |
INSULATION PIERCING CLIP |
ACCKIT-8 |
ACCESSORY KIT |
ADV-ASSESSMENT |
ADVANCED ENERGY ASSESSMENT KIT |
A-FLK434-CD |
Self-Paced CD-ROM instruction for the 433 & 434 |
AN5 |
CABLE, ANALOG OUTPUT 1.5 M (5F) FOR FLUKE-57X SERIES |
ANALYST2050 |
AC/DC TRMS 2000A POWER CLAMP - Discontinued - replaced by Fluke 345 |
ANALYST2060 |
60.98.69.017.0, AC/DC TRMS 2000A POWER Q CLAMP - Discontinued - replaced by Fluke 345 |
ANALYST3P EU/UK |
PQ ANALYZER INC 4 FLEX SET EU/UK - Discontinued - no replacement |
ANALYST3P US |
PQ ANALYZER INC 4 FLEX SET, US - Discontinued - replaced by Fluke 1735 |
ANALYST3Q EU/UK |
PQ ANALYZER INC 4PH FLEX SET EU/UK |
ANALYSTQ70 |
PQ ANALYZER SINGLE PHASE INC FLEX - Discontinued - replaced by Fluke 345 |
AS190-G |
PROBE ACCESSORY SET GREY - Discontinued - no replacement |
AS190-R |
PROBE ACCESSORY SET RED - Discontinued - no replacement |
AS200-G |
PROBE ACCESSORY SET GREY, VP PROBES |
AS200-R |
PROBE ACCESSORY SET RED, VP PROBES |
AS400 |
Probe accessory set, for VPS400 probes |
ASSESSMENT |
ENERGY ASSESSMENT KIT |
AUDIT |
ENERGY AUDIT KIT |
B2P-TI10/TIR |
BRONZE CAREPLAN TI10/TIR 2 YR |
B2P-TI25/TIR1 |
BRONZE CAREPLAN TI25/TIR1 2 YR |
B2P-TI32/TIR32 |
BRONZE CAREPLAN TI32/TIR32 2 YR |
B3P-TI10/TIR |
BRONZE CAREPLAN TI10/TIR 3 YR |
B3P-TI25/TIR1 |
BRONZE CAREPLAN TI25/TIR1 3 YR |
B3P-TI32/TIR32 |
BRONZE CAREPLAN TI32/TIR32 3 YR |
BATTERY |
BATTERY,PRIMARY,ALKALINE,9V,0-200MA - Discontinued - no replacement |
BB120 |
SET OF 2 BANANA TO BNC ADAPTOR |
BC1735 |
BATTERY CHARGER,UNIVERSAL |
BC190/803 |
BATTERY CHARGER - Discontinued - no replacement |
BC190/808 |
BATTERY CHARGER, UNIVERSAL |
BC190/813 |
BATTERY CHARGER, US |
BC430 |
BATTERY CHARGER 230V/110V |
BC7217 120 |
BATTERY CHARGER, NIMH |
BCP-TI10/TIR |
BRONZE CAREPLAN TI10/TIR 1 YR |
BCP-TI25/TIR1 |
BRONZE CAREPLAN TI25/TIR1 1 YR |
BCP-TI32/TIR32 |
BRONZE CAREPLAN TI32/TIR32 1 YR |
BE345 |
UNIVERSAL BATTERY ELIMINATOR FOR FLUKE-345 |
BE860 120 |
BATTERY ELIMINATOR, USA VER, 86X SER - Discontinued - no replacement |
BE9005 120 |
BATTERY ELIMINATOR |
BOOK-ITP |
INTRODUCTION TO THERMOGRAPHY PRINCIPLES Must be ordered in multiples of 5 |
BP120 |
Battery Pack - Discontinued - replaced by Fluke BP120MH |
BP120MH |
RECHARGEABLE BATTERY PACK FOR 43, 43B & 123 |
BP130 |
NIMH BATTERY PACK - Discontinued - replaced by Fluke BP120MH |
BP189 |
HIGH CAPACITY BATTERY PACK FOR FLUKE 180 SERIES |
BP190 |
NIMH BATTERY PACK |
BP291 |
LI-ION BATTERY PACK, DOUBLE CAPACITY, FLUKE 190-SERIESII |
BP7217 |
NICAD BATTERY PACK - Discontinued - replaced by Fluke BP7235 |
BP7235 |
NIMH BATTERY PACK |
BP880 |
BNC FEMALE TO DOUBLE STACKING BANANA PLUG |
BP881 |
BNC MALE TO DOUBLE STACKING BANANA PLUG |
BP980 |
DUAL BANANA PLUG KIT |
C10 |
HOLSTER |
C100 |
UNIVERSAL CARRYING CASE |
C101 |
HARD CASE |
C115 |
CARRYING CASE, POLYESTER, BLK/YEL |
C116 |
CARRYING CASE, POLYESTER, BLK/YEL |
C120 |
HARD CARRYING CASE FOR 120 SERIES |
C125 |
COMPACT SOFT CASE 120 SERIES |
C12A |
SOFT CARRYING CASE |
|
|
C1600 |
METER GEAR BOX |
C190 |
HARDCASE SM 190 SERIES |
C195 |
SOFTCASE |
C20 |
HARD CARRYING CASE FOR FLUKE-25/27 |
C23 |
SOFT CASE,VINYL,BLACK |
C25 |
SOFT CASE FOR FLUKE-25/27/8025A |
C280 |
CARRYING CASE, POLYESTER, BLK/YEL |
C290 |
HARD-SHELL CARRYING CASE |
C30 |
SOFT HOLSTER - Discontinued - no replacement |
C31 |
SOFT CASE FOR MODEL 30 - Discontinued - no replacement |
C33 |
SOFT CASE,VINYL,BLACK/YELLOW |
C345 |
SOFT CARRYING CASE, POLYESTER, BLK/YEL |
C35 |
CARRYING CASE, POLYESTER, BLK/YEL |
C36 |
SOFT CASE FOR MODEL 36 - Discontinued - no replacement |
C40 |
SOFT CASE, FOR FLUKE - 45 - Discontinued - no replacement |
C43 |
SOFT CARRYING CASE |
C430 |
HARD CARRYING CASE |
C435 |
WATER-TIGHT HARD CASE W/ROLLERS |
C50 |
CARRYING CASE |
C510 |
METER CASE,LEATHER,LARGE |
C520 |
TESTER CASE, LEATHER, SMALL - Discontinued - replaced by Fluke C520A |
C520A |
TESTER CASE,LEATHER |
C530 |
LEATHER ACCESSORY CASE - Discontinued - no replacement |
C550 |
PREMIUM TOOL BAG |
C570 |
SOFT CASE, 57X SERIES |
C700 |
HARD CARRYING CASE (700 SERIES) |
C70G |
HOLSTER WITH FLEX - STAND (GREY) - Discontinued - no replacement |
C70Y |
Holster With Flex-Stand (Yellow) - Discontinued - no replacement |
C75 |
CARRYING CASE |
C781 |
SOFT CARRYING CASE |
C789 |
SOFT CARRYING CASE |
C800 |
CARRYING CASE |
C81G |
HOLSTER & FLEXSTAND (GRAY) - Discontinued - replaced by Fluke H80M |
C81Y |
HOLSTER & FLEXSTAND (YELLOW) - Discontinued - replaced by Fluke H80M |
C90 |
CARRYING CASE |
C95 |
SCOPEMETER SOFT CARRYING CASE - Discontinued - replaced by Fluke C195 |
C97B |
Scopemeter Hard Carrying Case - Discontinued - no replacement |
C98 |
Automotive Hardcase - Discontinued - replaced by Fluke C195 |
CAP90-2 |
Capacitive Pickup - Discontinued - replaced by Fluke PM9096/201 |
CF1760-2GB |
X76980200000,2GB COMPACT FLASH CARD |
CO-205 |
CARBON MONOXIDE ASPIRATOR KIT |
CO-210 |
CARBON MONOXIDE SENSOR ACCESSORY - Discontinued - no replacement |
CO-220 |
CARBON MONOXIDE METER |
CS1750/1760 |
CASE POLYESTER, FOR FLUKE 1750 & 1760 |
CS1760 |
X57320800100,CROSSOVER ETHERNET CABLE |
CS20MA |
CURRENT SHUNT 4-20MA |
CXT170 |
RUGGED PELICAN HARD CASE, 170 SERIES |
CXT280 |
RUGGED PELICAN HARD CASE, 280 SERIES |
CXT80 |
RUGGED PELICAN HARD CASE, 80/180 SERIES |
D6100 SHUNT 10A |
TRIAXIAL-SHUNT 10A |
D6K SHNT TRIAX/BNC |
ADAPTER CABLE TRIAXIAL TO BNC 1.5M |
D6K SHT EXT 100A |
A641401300, EXTERNAL SHUNT 100A |
D6K SHT PLG 30A |
A641401100, PLUG-ON SHUNT 30A |
DIS90/801 |
DIS90 IGNITION ADAPTER - Discontinued - no replacement |
DP120 |
DIFFERENTIAL PROBE |
DPE90 |
DIESEL PROBE EXT.SET - Discontinued - no replacement |
DPS90 |
DIESEL PROBE SET - Discontinued - no replacement |
DR80 |
80 SERIES METER DISPLAY UPGRADE KIT |
E438080015 |
Conn Cbl 1-Phz For Analyst 3Q, Mb800/300 Smart - Discontinued - no replacement |
E461930001 |
Claw Gripp Black For Voltage Adapting - Discontinued - replaced by Fluke TLK291 |
E461930002 |
Claw Gripp Red For Voltage Adapting - Discontinued - no replacement |
E461930012 |
Safety-Claw Gripp Blk, W/Fuse Up To 100Ka |
E461930020 |
Fuse For Safety-Claw Gripp 2A, Type Hlk-2 - Discontinued - replaced by Fluke TLK291 |
E631820090 |
PERMLINK FOR REMOTE ACCESS VIA MODEM - Discontinued - no replacement |
EA1008Z |
RS232 - ETHERNET CONVERTER |
EA1020Z |
BINDING POST OPTION FOR NORMA 4000 |
EA1092Z |
POWER VIEW STORAGE FOR MEMORY SUPPORT |
EBC290 |
External battery charger, LI-ion battery, BP290 Series |
EG0001Z |
Voltage Probe 480V - Discontinued - no replacement |
EI-1623 |
SELECTIVE/STAKELESS CLAMP SET FOR 1623,CONSISTS OF EI-162X AND EI-162AC |
EI-1625 |
A604510304,SELECTIVE/STAKELESS CLAMP SET,WITH EI-162X,EI-162AC AND 2-3 WIRE CABLE - Discontinued - no replacement |
EI-162AC |
60.95.62.001.0F,CLIP-ON CURRENT TRANSFORMER (INDUCING) |
EI-162BN |
A680506211,12.7 INCH (320MM) SPILT CORE TRANSFORMER |
EI-162X |
60.95.62.005.0F,CLIP-ON CURRENT TRANSFORMER (SENSING) WITH SHIELDED CABLE SET |
EK0609Z |
LICENSE FOR MEASURING FUNCTION A, MEMOBOX 808-P - Discontinued - no replacement |
EK0610Z |
LICENSE FOR MEASURING FUNCTION A, MEMOBOX 808-Q - Discontinued - no replacement |
EK0611Z |
LICENSE FORMEASURING FUNCTION A, MEMOBOX 808-P+Q - Discontinued - no replacement |
EP0004A |
ETHERNET CABLE-SET - Discontinued - no replacement |
EP0020A |
Tool For Replacing The Fuse Of Safety Adapter - Discontinued - replaced by Fluke TLK291 |
EP0345A |
Safety Adapter For European Mains Outlets - Discontinued - no replacement |
EP0345F |
Safety Adapter For French Mains Outlets - Discontinued - no replacement |
EP0345W |
Safety Adapter For Swiss Mains Outlets - Discontinued - no replacement |
EP0401A |
Lemflex Set 15A/150A/1500A/3000A, 1-Phz, 2M Cbl - Discontinued - no replacement |
EP0441A |
Current Clamp Set 1A/10A, Single Phase, 2M Cable |
EP0457A |
Current Clamp Set 100A/1000A, 3-Phase, 2M Cable Discontinuing 9/30/06 |
EP0458A |
Current Clamp Set 100A/1000A, 3-Phz + N, 2M Cbl |
EP0606A |
Testlead For Connection Of 1 Current Clamp - Discontinued - no replacement |
EP0888Z |
POCKET PC W/INSTALLED CODAM PDA S/W, EU OUTLETS - Discontinued - no replacement |
EP1045A |
OPTION EXTENDED TEMPERATURE RANGE UP TO 45C |
ES-162P3 |
A604510302,STAKE SET FOR 3 POLE MEASUREMENT |
ES-162P4 |
A604510301,STAKE SET FOR 4 POLE MEASUREMENT |
FC-001 |
Fluke Safety Video - CD Rom |
FC-002 |
Fluke Safety Video - DVD |
FC-004 |
Fluke Safety Resource Kit - Discontinued - no replacement |
FK-01 |
Black Sport Cap - Discontinued - no replacement |
FK-02-LAR |
Black Pique Polo, Large - Discontinued - no replacement |
FK-02-XL |
Black Pique Polo, X-Large - Discontinued - no replacement |
FK-51 |
Black MSA V-Gard Hat - Discontinued - no replacement |
FK-56-2XL |
Devon & Jones Three Season Jacket, 2X-Large - Discontinued - no replacement |
FK-56-LAR |
Devon & Jones Three Season Jacket, Large - Discontinued - no replacement |
FK-56-XL |
Devon & Jones Three Season Jacket, X-Large - Discontinued - no replacement |
FK-574L |
Large - Highland Bay Black Twill Shirt Men's - Discontinued - no replacement |
FK-575XL |
X-Large - Highland Bay Black Twill Shirt Men's - Discontinued - no replacement |
FK-60 |
Laser Level with 5 inch tripod - Discontinued - no replacement |
FK-62 |
Carpenter Pencils - 125/pkg - Discontinued - no replacement |
FK-65 |
Black lunch box - Discontinued - no replacement |
FK-66 |
Gel knee pads - Discontinued - no replacement |
FLEX PSU-EU |
RR3030 EU POWER SUPPLY EXTERNAL - Discontinued - no replacement |
FLEX PSU-UK |
RR3030-UK POWER SUPPLY EXTERNAL - Discontinued - no replacement |
FOC-ST/FC |
ST TO FC JUMPER CABLE - Discontinued - no replacement |
FOC-ST/SC |
ST TO SC JUMPER CABLE - Discontinued - no replacement |
FOC-ST/SMA |
ST TO SMA JUMPER CABLE - Discontinued - no replacement |
FOC-ST/ST |
ST TO ST JUMPER CABLE - Discontinued - no replacement |
FOM |
FIBER OPTIC METER |
FOS-850 |
FIBER OPTIC SOURCE (850) |
FOS-850/1300 |
FIBER OPTIC SOURCE (850/1300) |
FP |
FOODPRO FOOD SAFETY THERMOMETER |
FP PLUS |
FOODPRO PLUS FOOD SAFETY THERMOMETER |
FP-PROBE |
PROBE FOR FOODPRO PLUS |
FS17XX |
SHIELDED 4-PHASE FLEXI SET FOR MODELS 1735, 1743, 1744, 1745 |
FS17XX IP65 |
IP65 RATED 4-PHASE FLEXI SET FOR MODELS 1735, 1743, 1744, 1745 |
FS17XX/1PH |
SHIELDED 1-PHASE FLEXI SET FOR MODELS 1735, 1743, 1744, 1745 |
FTP |
FUSED TEST PROBE, SET |
FTPL |
FUSED TEST PROBE SET WITH TEST LEADS |
FUSE |
FUSE,.406X1.375,0.440A,1000V,FAST - CUST SHOULD BUY BLISTER PACKS FOR FLUKE-8X SERIES "IEC 101" UNITS ONLY - Discontinued - replaced by Fluke FUSE 943121 |
Fuse 203403 |
FUSE, 11A, 1000V, FAST, B. PK, QTY 1 |
Fuse 203406 |
FUSE, 11A, 1000V, FAST, LOT QTY 5 |
Fuse 203411 |
FUSE,440MA, 1000V, FAST, B.PK, QTY 1 |
Fuse 203414 |
FUSE,440MA, 1000V, FAST, LOT QTY 5 |
FUSE 643684 |
FUSE,.406X1.5,20A,600V,FAST |
Fuse 686527 |
Fluke 715 - FUSE, 125mA ,250V, Fast |
FUSE 713057 |
FUSE, FAST 2A 250V LOT QTY 25 |
FUSE 713099 |
FUSE, FIBRE 3A 600VAC LOT QTY 25 |
FUSE 717215 |
FUSE, FIBER, 20A 600VAC, LOT QTY 25 |
FUSE 803293 |
11A,1000V,FAST.406INX1.5IN,BULK |
FUSE 812396 |
FUSE,LOT QTY 25,FAST,.63A,250V,5X20MM |
FUSE 812404 |
FUSE,LOTQTY 25,FAST,2A,600V |
Fuse 830828 |
Fuse, 1A, 600V 1-Piece - Discontinued - no replacement |
FUSE 847793 |
FUSE,LOT QTY 25,FAST,15A, 600V |
Fuse 871173 |
FUSE,630MA 250V,5X20MM FAST,LOT QTY 5 |
Fuse 871178 |
FUSE,2A 250V, 1 X .25 FAST, LOT QTY 5 |
FUSE 871194 |
FUSE,FIBER, 20A 600VAC, LOT QTY 5 |
Fuse 871202 |
FUSE, 3A, 600V, PKG/5 |
Fuse 871207 |
FUSE, FIBER, 1A 600V, FAST, LOT QTY 5 - CAUTION! SAFETY ISSUE FOR F-8X SERIES. DO NOT USE ABOVE SN 66290001 FOR F-83. NOT ABOVE SN 66340001 FOR F-85, OR ABOVE SN 65650001 FOR F-87 |
FUSE 871210 |
FUSE, FIBER, 1A 600V,FAST, LOT QTY 25 |
Fuse 871215 |
FUSE, FIBER, 2A 600V, FAST, LOT QTY 5 |
FUSE 871223 |
LOT QTY 5 ,FUSE, FIBER, 15A 600V,FAST, CAUTION! SAFETY ISSUE FOR FLUKE- 83, 85 & 87. DO NOT USE THIS FUSE ABOVE SN 65650000 |
Fuse 892583 |
FUSE,15A, 600V, .406X1.5, FAST,QTY 1 - CAUTION! SAFETY ISSUE FOR F-8X SERIES. DO NOT USE ABOVE SN 66290001 FOR F-83. NOT ABOVE SN 66340001 FOR F-85, OR ABOVE SN 65650001 FOR F-87 |
FUSE 943121 |
FUSE,.406X1.375,0.440A,1000V,FAST - CUST SHOULD BUY BLISTER PACKS FOR FLUKE-8X SERIES "IEC 101" UNITS ONLY |
FVF-BASIC |
FLUKEVIEWFORMS WITH CABLE FOR USE WITH 180 SERIES METERS |
FVF-SC1 |
FLUKEVIEW FORMS W/CABLE F/53-2,54-2,87-4,89-4 METERS - Discontinued - no replacement |
FVF-SC2 |
FLUKEVIEW FORMS WITH CABLE FOR USE WITH 18X, 28X DMMS |
FVF-SC3 |
FLUKEVIEW FORMS W/CABLE FOR 45 DMM |
FVF-SC4 |
FLUKEVIEW FORMS W/CABLE FOR 8845/8846 |
FVF-SC5 |
FLUKEVIEW FORMS - BASIC FOR 8845/8846 |
FVF-UG |
FLUKEVIEW FORMS UPGRADE |
G2P-TI10/TIR |
GOLD CAREPLAN TI10/TIR 2 YR |
G2P-TI25/TIR1 |
GOLD CAREPLAN TI25/TIR1 2 YR |
G2P-TI32/TIR32 |
GOLD CAREPLAN TI32/TIR32 2 YR |
G3P-TI10/TIR |
GOLD CAREPLAN TI10/TIR 3 YR |
G3P-TI25/TIR1 |
GOLD CAREPLAN TI25/TIR1 3 YR |
G3P-TI32/TIR32 |
GOLD CAREPLAN TI32/TIR32 3 YR |
GCP-TI10/TIR |
GOLD CAREPLAN TI10/TIR 1 YR |
GCP-TI25/TIR1 |
GOLD CAREPLAN TI25/TIR1 1 YR |
GCP-TI32/TIR32 |
GOLD CAREPLAN TI32/TIR32 1 YR |
Geo 30 |
Earth Ground Clamp - Discontinued - replaced by Fluke 1630 |
GEO 30 SERV KIT |
Geo 30 Ground Serv. Kit |
GEO CABLE-REEL 25M |
A604505102, GROUND/EARTH CABLE REEL 25M WIRE |
GEO CABLE-REEL 50M |
A604505103, GROUND/EARTH CABLE REEL 50M WIRE |
GEO EARTH STAKE |
A604510350, GROUND/EARTH EARTH STAKE |
GEO PLUS S2 |
A604510307, Geo Plus Stakeless 2 Clamp Set - Discontinued - no replacement |
GEO PLUS SELECT S1 |
A604510305, Geo Plus Selective 1 Clamp Set - Discontinued - no replacement |
GEO PLUS STAKEL S2 |
GEO PLUS STAKELESS 2 CLAMP SET - Discontinued - no replacement |
GEO SET 3 POLE |
A604510302, Ground/Earth 3 Pole Access Set - Discontinued - no replacement |
GEO SET 4 POLE |
A604510301, Ground/Earth 4 Pole Access Set - Discontinued - no replacement |
GEO TEST LEAD-SET |
A604510211, Ground/Earth 2 Leads W/Clips - Discontinued - no replacement |
GEO XS BUNDLE 1 |
Bundle Geoxs,Busbar Clamp,Lk60,1550Yz Case - Discontinued - no replacement |
GEOX CABLESET |
A640306311, GEOX ADPTR CBL SET FOR STAKELESS |
GEOX PROBE CABLE |
A600209300, GEOX CONN CABLE FOR SELECTIVE CLAMP |
GEOX SELECTIVE S1 |
A604510303, Geox Selective 1 Clamp Access Set - Discontinued - no replacement |
GEOX SELECTIVE S2 |
A680506211, Split-Core Transformer 320Mm Dia - Discontinued - no replacement |
GEOX STAKELESS S2 |
A604510304, Geox Stakeless 2 Clamp Access Set - Discontinued - no replacement |
GPS430 |
GPS SYNC MODULE FOR FLUKE 430 SERIES |
GPS-TIME SYNC |
EP2050Z, OPTION GPS TIMESYNC FOR FLUKE-1760 AND TOPAS 2000 |
H3 |
HOLSTER WITH ACCESSORY POCKET,333 - 337 CLAMP METERS |
H5 |
HOLSTER,BELT,ACCESSORY |
H6 |
IR-PISTOL-HOLSTER |
H80M |
PROTECTIVE HOLSTER WITH MAGNETIC HANGING STRAP |
H900 |
TEST LEAD HOLDER |
HANDY GEO |
A188503110, Earth Ground Meter 3 Pole - Discontinued - no replacement |
HANDY GEO W/ACC |
A188503111, Earth Ground Meter Inc 3 Pole Set - Discontinued - no replacement |
HANDY ISO |
A186503211, Insulation Testr 100/250/500V 20Gohm - Discontinued - suggested replacement: LEM HANDY ISO |
HART DRYWELL CABLE |
CABLE KIT, HART DRYWELL CONTROL |
HC120 |
SET OF 2 HOOK CLIPS |
HC200 |
HOOK CLIP SET, 2 RED 2 GRAY |
HEME GEO 30 |
CLAMP-ON GROUND LOOP TESTER - Discontinued - suggested replacement:LEM HEME GEO 30 |
HEME ISO 1000 |
AC/DC CURRENT CLAMP DMM + INSUL TESTER - Discontinued - no replacement |
HEME ISO 2000 |
AC/DC CURRENT CLAMP DMM + INSUL TESTER - Discontinued - no replacement |
HFR3000 |
60.30.71.010.0, Flex Ac 300/3000A 1Hz-1Mhz Osc - Discontinued - no replacement |
HP IPAQ 2490 |
COMPUTER,HANDHELD,IPAQ 2490 POCKET PC,520MHZ,64MB,INDIVIDUAL -Discontinued - no replacement |
HT1521-156 |
THERMOMETER, HH, 1 CHNL, 110V 50/60HZ |
HT1522-156 |
THERMOMETER, 1-CHNL LOGGER, 110V 50/60HZ |
HT561091 |
PROBE, THERMISTOR 1/8IN X 9IN STAINLESS |
HT5611TI |
PROBE, BARE THERMISTOR - TEFLON |
HT56129I |
PROBE, SECONDARY PRT, 100 OHM 3/16 X 9IN |
HT56136I |
PROBE, SECONDARY PRT, 100 OHM 3/16 X 6IN |
HT561412I |
PROBE, SECONDARY PRT, 100 OHM 1/4IN X 12IN |
HT56189I |
PROBE, SECONDARY PRT, 9IN X 1/8IN OD |
HT562205I |
PROBE, FAST RESPONSE, 0.5MM DIA. |
HT562712I |
PROBE, RTD INDUSTRIAL 12IN X 1/4IN OD |
HT56276I |
PROBE, RTD INDUSTRIAL 6IN X 3/16IN OD |
HT56279I |
PROBE, RTD INDUSTRIAL 9IN X 3/16IN OD |
HT9009-B-156 |
DRY-WELL, DUAL-BLOCK (BLACK), 110V 50/60HZ |
HT9132-156 |
CALIBRATOR, IR, 110V 50/60HZ |
HT9308 |
CASE, HARD CARRYING (9102/9132) |
HT9318 |
CASE, CARRYING (1521/1522 & PROBE) |
HT9934-M |
SOFTWARE, LOGWARE, 1-CHAN, MULTI USER |
HT9934-S |
SOFTWARE, LOGWARE, 1-CHAN, SINGLE USER |
I1000S |
AC CURRENT CLAMP |
I1010 |
AC/DC CURRENT CLAMP,1000A DC,600A AC |
I1010-KIT |
AC/DC CURRENT CLAMP W/METER CARRY CASE |
I1A/10A CLAMP PQ1 |
1-PHASE 1A/10A MINI CURRENT CLAMP SET FOR PQ |
I1A/10A CLAMP PQ3 |
3-PHASE 1A/10A MINI CURRENT CLAMP SET FOR PQ |
I1A/10A CLAMP PQ4 |
4-PHASE 1A/10A MINI CURRENT CLAMP SET FOR PQ |
I20/200A CLAMP PQ3 |
3-PHASE 20A/200A MINI CURRENT CLAMP SET FOR PQ |
I20/200A CLAMP PQ4 |
4-PHASE 20A/200A MINI CURRENT CLAMP SET FOR PQ |
I200 |
200 AMP CLAMP, CURRENT OUTPUT, BANANA |
I2000 FLEX |
AC CURRENT PROBE |
I2000PQ4 |
2000 Flex Current Clamp, 4 Pack - Discontinued - replaced by Fluke I3000 FLEX-4PK |
I200S |
200 AMP CLAMP, VOLTAGE OUTPUT, BNC |
I2500-10 |
IFLEX 2500A PROBE 10IN |
I2500-18 |
IFLEX 2500A PROBE 18IN |
I30 |
AC/DC CURRENT CLAMP |
I3000 FLEX-4PK |
AC CURRENT PROBE,4 PACK |
I3000-FLEX-4PK |
AC CURRENT PROBE,4 PACK - Discontinued - replaced by Fluke I3000 FLEX-4PK |
I3000S |
AC CURRENT CLAMP |
I3000S FLEX-24 |
AC CURRENT PROBE |
I3000S FLEX-36 |
AC CURRENT PROBE |
I30S |
AC/DC CURRENT CLAMP |
I310S |
AC/DC CURRENT CLAMP |
I400 |
AC CURRENT CLAMP |
I400S |
AC CURRENT CLAMP |
I410 |
400A AC/DC CURRENT CLAMP |
I410-KIT |
AC/DC CURRENT CLAMP WITH CARRY CASE |
I430-FLEX |
AC FLEX CURRENT PROBE 3000A |
I430-FLEX-4PK |
AC FLEX CURRENT PROBE 3000A 4 PACK |
I50S |
AC/DC SCOPE CURRENT PROBE,50MHZ |
I5A/50A CLAMP PQ1 |
1-PHASE 5A/50A MINI CURRENT CLAMP SET FOR PQ |
I5A/50A CLAMP PQ3 |
3-PHASE 5A/50A MINI CURRENT CLAMP SET FOR PQ |
I5A/50A CLAMP PQ4 |
4-PHASE 5A/50A MINI CURRENT CLAMP SET FOR PQ |
I5S |
5A AC CURRENT PROBE |
I5SPQ3 |
5A AC CURRENT PROBE 3 PACK FOR 430 |
I6000S FLEX-24 |
AC CURRENT PROBE |
I6000S FLEX-36 |
AC CURRENT PROBE |
I800 |
AC CURRENT CLAMP |
INSXS-20 |
IR INSIGHT XS THERMAL IMAGER - Discontinued - no replacement |
INSXST-20 |
IR INSIGHT XST THERMAL IMAGER - Discontinued - no replacement |
IR189USB |
USB CABLE FOR FLUKE-189 DMMS |
ISO-PLUS |
Si1310Z, Insulation Tester&Trms Multimeter - Discontinued - no replacement |
ITP120 |
ISOLATED TRIGGER PROBE |
KIT-87 |
Fluke 87 Multimeter Service Kit - Discontinued - no replacement |
L200 |
PROBE LIGHT |
L205 |
MINI HAT LIGHT |
L206 |
DELUXE LED HAT LIGHT |
L207 |
HIGH INTENSITY LIGHT W/LTD EDITION FLUKE CAP |
L210 |
PROBE LIGHT AND PROBE EXTENDER |
L211 |
PROBE LIGHT KIT |
L215 |
SUREGRIP KIT WITH PROBE LIGHT AND PROBE EXTENDER |
LENS/TELE1 |
INFRARED TELEPHOTO LENS 1 |
LENS/WIDE1 |
INFRARED WIDE-ANGLE LENS 1 |
LH1010 |
60.56.60.004.0, Ac/Dc Clamp 400/1000A 100Ma Res - Discontinued - no replacement |
LH1020 |
60.56.60.000.0, Ac 400/1000A Clamp - Discontinued - no replacement |
LH1025 |
60.56.60.001.0, Ac Trms 400/1000A Clamp - Discontinued - no replacement |
LH1035 |
60.56.60.006.0, Ac/Dc Trms 400/1500A Clamp - Discontinued - no replacement |
LH1040 |
60.56.60.002.0, Ac/Dc Trms 400/1000A Clamp - Discontinued - no replacement |
LH1050 |
60.56.60.020.0, AC/DC TRMS 1000A POWER CLAMP Available thru 12/31/07 only -Discontinued - suggested replacement: LEM LH1050 |
LH1060 |
60.56.60.021.0, AC/DC TRMS 1000A POWER Q CLAMP - Discontinued - no replacement |
LH2015 |
60.56.69.001.0, AC/DC TRMS 400/2000A CLAMP - Discontinued - replaced byFluke 353 or Fluke 355 |
LH2040 |
60.56.69.000.0, Ac/Dc Trms 400/2000A Clamp Dmm - Discontinued - no replacement |
LH240 |
60.56.45.000.0, Ac/Dc Trms 40/200A Clamp - Discontinued - no replacement |
LH41 |
60.56.60.015.0, Ac/Dc Clamp 4/40A 1Ma Resolution - Discontinued - suggested replacement: Amprobe LH41A |
LH410 |
60.56.60.011.0, Ac/Dc Clamp 40/400A 10Ma Res - Discontinued - no replacement |
LH630 |
60.56.52.000.0, Ac/Dc 400/600A Clamp - Discontinued - no replacement |
LH635 |
60.56.52.001.0, Ac/Dc Trms 400/600A Clamp - Discontinued - no replacement |
LIGHTNING PROTECTR |
EF2055Z,LIGHTNING PROTECTION - GPS ANTENNA ONLY - Discontinued - no replacement |
LK60 |
Low Current Leakage Clamp Meter - Discontinued - no replacement |
LPAK80-4 |
LOCKPAK - Discontinued - no replacement |
LS50 PSU |
90.32.11.702.0, Power Supply Pr50 - Discontinued - no replacement |
LVD1 |
VOLT LIGHT |
LVD2 |
VOLT LIGHT |
LVD2/CT |
LVD2 WITH COUNTER TOP DISPLAY |
M00-200-634 |
RACKMOUNT KIT - Discontinued - no replacement |
MA190 |
SCMTR MEDICAL ACC KIT |
MARKETING MATL |
VIDEO,PQ TROUBLESHOOTING,NTSC |
MARKETING MATL02 |
VIDEO, ABC'S OF DMM SAFETY |
MARKETING MATL1 |
VIDE0,UNDERSTAND/MANAGE HARMONICS |
MARKETING MATL2 |
VIDEO,PQ TROUBLESHOOTING,NTSC |
MBX 300 CARRY BAG |
Ep0350A, Carrying Bag, Mbx300 - Discontinued - no replacement |
MBX 300 POLESET |
EP0340A.Z, MOUNTING KIT F. MBX 300 SMART - Discontinued - no replacement |
MBX 300-3U |
Ep0461Z, Memobox 300 Smart (3U) |
MBX 300-3U+3I |
Ep0462Z, Memobox 300 Smart (3U + 3I, P), 3 Phaze |
MBX 300-3U+3I-UK |
Ep0462G, Memobox 300 Smart (3U + 3I, P) Uk Ver. |
MBX 300-CASE |
A603000540, Carrying Case, Memobox300 Smart+Accy - Discontinued - no replacement |
MBX 3PH FLEX 4M |
Ep0403Z, Lemflex , 3 Phase, 4 M Cable - Discontinued - no replacement |
MBX 4PH FLEX 2M |
Ep0404A, Lemflex, 3 Phase +N, 2M Cable - Discontinued - no replacement |
MBX 4PH FLEX 4M |
EP0404Z, LEMFLEX, 3 PHASE + N, 4M CABLE - Discontinued - no replacement |
MBX 808 CARRY BAG |
E029790800, Carrying Bag For Memobox 808A - Discontinued - no replacement |
MBX CLAMP 1A/10A |
EP0450A, CURRENT CLAMPS 1A, 3-PHASE, 2M - Discontinued - replaced by Fluke I1A/10A CLAMP PQ3 |
MBX CLAMP 1A/10A+N |
EP0451A, CURRENT CLAMPS 1A/10A, 3-PHASE+N, 2M - Discontinued - no replacement |
MBX CLAMP 20A/200A |
EP0455A, CURRENT CLAMPS 20A/200A, 3-PHASE, 2M - Discontinued - no replacement |
MBX CLAMP 5A/50A |
EP0452A, CURRENT CLAMPS 5A/50A, 3-PHASE, 2M - Discontinued - no replacement |
MBX CLAMP 5A/50A+N |
EP0453A, CURRENT CLAMPS 5A/50A, 3-PHASE+N, 2M - Discontinued - no replacement |
MBX CLAW-GRIP |
E461930015, SAFETY CLAW GRIP WITH FUSE - Discontinued - no replacement |
MBX CLMP 20/200A+N |
EP0456A, CURRENT CLMP 20A/200A, 3-PHASE+N, 2M - Discontinued - no replacement |
MBX CODAM PLUS EXT |
Ek0410Z, Software - Discontinued - no replacement |
MBX E438080005 |
VOLTAGE TEST LEADS,3-PHASE,2M - Discontinued - no replacement |
MBX EP0450A |
Ep0450A, Current Clamps 1A/10A, 3-Phase, 2M - Discontinued - no replacement |
MBX FUSED CBL. |
EP0496W, FUSED TEST LEAD, 3-PHASE, CH - Discontinued - no replacement |
MBX GSM ADAPTER EU |
MAINS ADAPTER FOR GSM MODEM EU PLUG - Discontinued - no replacement |
MBX GSM ADAPTER GB |
MAINS ADAPTER FOR GSM MODEM GB, PLUG - Discontinued - no replacement |
MBX GSM ADAPTER US |
Ep0498U, Mains Adapter For Gsm Modem Us, Plug - Discontinued - no replacement |
MBX GSM MODEM |
EP0499Z, GSM-MODEM, PERMLINK IS REQUIRED - Discontinued - no replacement |
MBX USB-RS232 |
EP0328Z, USB TO SERIAL RS232 ADAPTER |
MBX300 3PITL |
EP0607A, TEST LEAD FOR 3 CLAMPS |
MBX300 3PTL4M |
EP0497Z, MEMOBOX 300 SMART 4M CONNECTING CABLE |
MBX300 4PITL |
EP0608A, TEST LEAD FOR 4 CLAMPS |
MBX300-1U+1IP |
Ep0463Z, Mbx300 Smart (1 U + 1 I, P), 1 Phaze |
MBX300-1U+1I-Q |
Ep0493Z, Memobox 300 Smart (1 U + 1 I, Q) |
MBX300-3U+3I-A |
Ep0492A, Memobox 300 Smart (3 U + 3 I, A) |
MBX3003U+3I-A-UK |
Ep0472A, Memobox 300 Smart (3 U + 3 I, A) Uk Ver |
MBX300-3U+3I-Q |
Ep0492Z, Memobox 300 Smart (3 U + 3 I, Q) |
MBX3003U+3I-Q-UK |
Ep0472G, Mbx 300 Smart (3 U + 3 I, Q) Uk Version |
MBX300-3U+4I-A |
Ep0494A, Memobox 300 Smart (3 U + 4 I, A) |
MBX3003U+4I-A-UK |
Ep0474A, Memobox 300 Smart (3 U + 4 I, A) Uk Ver |
MBX300-3U+4IP |
Ep0464Z, Memobox 300 Smart (3 U + 4 I, P) |
MBX3003U+4I-P-UK |
Ep0464G, Mbx300 Smart (3 U + 4 I, P) Uk Version |
MBX300-3U+4I-Q |
Ep0494Z, Memobox 300 Smart (3 U + 4 I, Q) |
MBX3003U+4I-Q-UK |
Ep0474G, Memobox 300 Smart (3 U + 4 I, Q) Uk Ver |
MBX300-3U-Q |
Ep0491Z, Memobox 300 Smart (3 U, Q) |
MC50 |
METERCLEANER WIPES, 50-PACK |
MC6 |
METERCLEANER WIPES, 6-PACK |
MEMOBOX 300A |
Ep0494U, Mbx300 Smart(3U+4I, Q) Inc Flex Set - Discontinued - no replacement |
MEMOBOX 300P |
Ep0464U, Mbx300 Smart(3U+4I, P) Inc Flex Set - Discontinued - no replacement |
MEMOBOX 808 (P) |
Ep0808D.P, Pwr Quality Analyzer For Pq Analysis |
MEMOBOX 808 (Q) |
Ep0808D.Q, Pwr Quality Analyzer For Pq Analysis |
MEMOBOX 808A |
Ep0808U, Mbx 808 (A) (3U+4I) Inc Flex Set & Psu - Discontinued - no replacement |
MS190 |
SCMTR MEDICAL SW KIT - Discontinued - replaced by Fluke SCC190EFG |
MT-8200-204 |
Microscanner Pro VDV Kit 2003 Promo - Discontinued - replaced by Fluke MT-8200-24A |
MT-8200-22 |
MicroScanner Pro KitBusiness in a Box Special Edition - Discontinued - suggested replacement: Test-Um TP607 |
MT-8200-24A |
MICROSCANNER VDV PRO KIT - Discontinued - no replacement |