05522A1 Base Analyser (stainless steel pipework, flam |
able gases) |
|
|
GAS MODULE CONFIGURATION |
|
|
|
Gas Module |
Thermal Conductivity |
|
|
Sample/Background Gas |
H2 in Ar |
|
H2 in N2 |
|
H2 in CO |
|
|
Range |
0 - 1% Not available for "H2 in Ar" |
(Check VC for permitted ranges) |
0 - 2% Only available for "H2 in N2" |
0 - 5% Only available for "H2 in N2" |
0 - 10% Only available for "H2 in N2" |
0 - 20% Not available for "H2 in CO" |
0 - 50% Only available for "H2 in N2" |
0 - 100% Only available for "H2 in N2" |
90 - 100% Only available for "H2 in N2" |
|
|
Sample System |
Flow Driven |
|
|
Fascia Options |
Blank |
|
|
GENERAL CONFIGURATION |
. |
|
|
Power Supply |
UK Power Lead |
|
European Power Lead |
|
American Power Lead |
|
|
Analogue Output |
mA Output |
|
Voltage Output (0-10V) |
|
|
Digital Output |
Not Required |
|
ModBus RS485 |
|
ModBus TCP (Ethernet) |
|
Profibus |
|
|
Relay Option Card |
Not Required |
|
Alarms & Status |
|
Auto Val / Cal |
|
|
Mounting Option |
Bench |
|
Panel |
|
Rack |
|
|
User Manual |
English |
|
English (Russian MultiExact HW) |
|
|
|
|
|
|
|
|
SERVOPRO 4100 GAS PURITY ANALYSER |
|
|
|
04100C1 |
|
|
|
CHASSIS TYPE |
|
|
Short Chassis (max 2 short or 1 long sensor modules) |
|
Long Chassis (max 4 short or 2 long sensor modules) |
|
Extended chassis (max 2 long sensor modules) |
|
|
GAS SENSOR MODULE 1 |
|
Short Sensor Modules |
|
|
PM O2 Purity |
|
PM O2 Control |
|
PM O2 Basic |
|
Zr O2 703 Trace |
|
Zr O2 704 Trace |
|
1520 IR, 100% CO2 |
|
1520 IR, 50% CO2 |
|
1520 IR, 25% CO2 |
|
1520 IR, 10% CO2 |
|
1520 IR, 5% CO2 |
|
1520 IR, 2.5% CO2 |
|
1520 IR, 1% CO2 |
|
1522 IR, 10% CO |
Long Sensor Modules |
|
|
1520 IR, 5000vpm CO2 |
|
1520 IR, 2500vpm CO2 |
|
1522 IR, 2.5% CO |
|
1522 IR, 1% CO |
|
GFX CO 0-10/50vpm |
|
GFX CO 0-10/50vpm (background O2) |
|
GFX CO 0-50/500vpm |
|
GFX CO2 0-5/100vpm |
|
GFX CO2 0-50/500vpm |
|
GFX CO2 0-50/500vpm (background O2) |
|
GFX N2O 0-50/500vpm |
|
GFX N2O 0-50/500vpm (background O2) |
|
GFX CH4 0-50/500vpm |
|
**Simplified SIPS GFX CO 0-100/1000vpm** |
|
**Simplified SIPS GFX CO 0-500/5000vpm** |
|
**Simplified SIPS GFX CH4 0-100/1000vpm** |
|
|
GAS SENSOR MODULE 3 |
|
|
None |
Short Sensor Modules |
|
|
PM O2 Purity |
|
PM O2 Control |
|
PM O2 Basic |
|
Zr O2 703 Trace |
|
Zr O2 704 Trace |
|
1520 IR, 100% CO2 |
|
1520 IR, 50% CO2 |
|
1520 IR, 25% CO2 |
|
1520 IR, 10% CO2 |
|
1520 IR, 5% CO2 |
|
1520 IR, 2.5% CO2 |
|
1520 IR, 1% CO2 |
|
1522 IR, 10% CO |
Long Sensor Modules |
|
|
1520 IR, 5000vpm CO2 |
|
1520 IR, 2500vpm CO2 |
|
1522 IR, 2.5% CO |
|
1522 IR, 1% CO |
|
GFX CO 0-10/50vpm |
|
GFX CO 0-10/50vpm (background O2) |
|
GFX CO 0-50/500vpm |
|
GFX CO2 0-5/100vpm |
|
GFX CO2 0-50/500vpm |
|
GFX CO2 0-50/500vpm (background O2) |
|
GFX N2O 0-50/500vpm |
|
GFX N2O 0-50/500vpm (background O2) |
|
GFX CH4 0-50/500vpm |
|
**Simplified SIPS GFX CO 0-100/1000vpm** |
|
**Simplified SIPS GFX CO 0-500/5000vpm** |
|
**Simplified SIPS GFX CH4 0-100/1000vpm** |
|
|
SAMPLE SYSTEM FOR MODULE 1 |
|
|
Flow Driven PM |
|
Flow Driven Zr |
|
Flow Driven 152x series |
|
Flow Driven GFX |
|
Flow Driven GFX with flow alarm |
|
Pressure Driven PM |
|
Pressure Driven PM Basic |
|
Pressure Driven Zr |
|
Pressure Driven 152x series |
|
Pressure Driven GFX |
|
|
|
|
|
|
SAMPLE SYSTEM FOR MODULE 3 |
|
|
None |
|
Flow Driven PM |
|
Flow Driven Zr |
|
Flow Driven 152x series |
|
Flow Driven GFX |
|
Flow Driven GFX with flow alarm |
|
Pressure Driven PM |
|
Pressure Driven PM Basic |
|
Pressure Driven Zr |
|
Pressure Driven 152x series |
|
Pressure Driven GFX |
|
|
GAS SENSOR MODULE 2 |
|
Only available if a short sensor was selected for Module 1 |
|
|
None |
Short Sensor Modules |
|
|
PM O2 Purity |
|
PM O2 Control |
|
PM O2 Basic |
|
Zr O2 703 Trace |
|
Zr O2 704 Trace |
|
1520 IR, 100% CO2 |
|
1520 IR, 50% CO2 |
|
1520 IR, 25% CO2 |
|
1520 IR, 10% CO2 |
|
1520 IR, 5% CO2 |
|
1520 IR, 2.5% CO2 |
|
1520 IR, 1% CO2 |
|
1522 IR, 10% CO |
|
|
SAMPLE SYSTEM FOR MODULE 2 |
|
|
None |
|
Flow Driven PM |
|
Flow Driven Zr |
|
Flow Driven 152x series |
|
Pressure Driven PM |
|
Pressure Driven PM Basic |
|
Pressure Driven Zr |
|
Pressure Driven 152x series |
|
|
GAS SENSOR MODULE 4 |
|
Only available if a short sensor was selected for Module 3 |
|
|
None |
Short Sensor Modules |
|
|
PM O2 Purity |
|
PM O2 Control |
|
PM O2 Basic |
|
Zr O2 703 Trace |
|
Zr O2 704 Trace |
|
1520 IR, 100% CO2 |
|
1520 IR, 50% CO2 |
|
1520 IR, 25% CO2 |
|
1520 IR, 10% CO2 |
|
1520 IR, 5% CO2 |
|
1520 IR, 2.5% CO2 |
|
1520 IR, 1% CO2 |
|
1522 IR, 10% CO |
|
|
Long Sensor Modules |
|
Only available with extended chassis |
|
|
GFX CO 0-10/50vpm |
|
GFX CO 0-10/50vpm (background O2) |
|
GFX CO2 0-50/500vpm |
|
GFX CO2 0-50/500vpm (background O2) |
|
|
|
|
SAMPLE SYSTEM FOR MODULE 4 |
|
|
None |
|
Flow Driven PM |
|
Flow Driven Zr |
|
Flow Driven 152x series |
|
Flow Driven GFX (extended chassis only) |
|
Pressure Driven PM |
|
Pressure Driven PM Basic |
|
Pressure Driven Zr |
|
Pressure Driven 152x series |
|
Pressure Driven GFX (extended chassis only) |
|
|
SPR410 (BPV) |
|
|
Purity Module 1 |
|
Purity Module 2 |
|
Purity Module 3 |
|
Purity Module 4 |
|
|
FLOWMETER (LEFT) |
|
|
|