2930B SERVOTOUGH LaserSP  
   
02930B1 SERVOTOUGH LaserSP
CONFIGURATION  
  Single Path
AREA CLASSIFICATION  
  Safe Area
  ATEX  and IECEx Cat 3 Gas (Zone 2) Cat 2 Dust (Zone 21)
  ATEX Cat. 2G (Zone 1)
  CSA general purpose
  CSA Class 1, Division 2
   
MEASUREMENT  
Single Path monitors Measurement
   
  O2 SERVOTOUGH LaserSP Monitor (oxygen)
  HOT O2 SERVOTOUGH LaserSP Monitor (oxygen)
  CO SERVOTOUGH LaserSP Monitor, low level detection limit 0.3ppm (carbon monoxide)
  NH3 SERVOTOUGH LaserSP Monitor (ammonia)
   
MEASURING RANGE  
  Please state
MEASUREMENT UNITS  
  mg/m3
  ppm
  % vol
   
DUAL MEASUREMENT  
  Not Required
  Dual gas, add on temperature (for O2 and CO)
   
DUAL MEASURING RANGE  
  Please state
   
DUAL MEASUREMENT UNITS  
  mg/m3
  ppm
  % vol
  Celsius
   
  Gas Component 1
  Stream Comp 1 Normal Range
  Stream Comp 1 Low Range
  Stream Comp 1 High Range
  Process Dust (mg/m3)
  Process Flow (m3/h)
  Process Velocity (m/sec)
  Process Opacity (%)
  Stream Temperature (°C)
  Ambient Temperature (°C)
   
  Trans/Rec Cable 10m (5m supplied as standard)
  Trans/Rec Cable 15m (5m supplied as standard)
  Trans/Rec Cable 20m (5m supplied as standard)
  TU/RU Connecting Cable 5-20m (per metre). 5m supplied as standard.
   
  TU Optical Path Length L1 (mm)
  Stack Diameter L2 (mm)
  RU Optical Path Length L3 (mm)
   
PROCESS PRESSURE UNITS  
  mbar
  bar
   
PROCESS PRESSURE (bar)  
  Please specify
   
OPTICAL WINDOW PURGING  
  None (low dust)
  Instrument Air
  Fan
  N2 (low level O2)
  Steam
SUPPLY VOLTAGE  
  110Vac 50/60Hz
  220Vac 50/60Hz
  24Vdc
HIGH TEMPERATURE APPLICATIONS  
  High temp. O2/CO2/CO applications(>700C) RU Filter mounted/tested
  13606 High Temp O2 with Air Purge (>500C)
   
MOUNTING FLANGE  
  DN50/PN10 (SP Standard)
  DN80/PN10, pair
  ANSI 2"/150lbs, pair
  ANSI 3"/300lbs, pair
   
   
  ANSI 4" 150/300lbs, pair
  Other (Specify)
   
SPECIAL FLANGE O-RINGS 21031 DN50 Flange 0-ring, 65.0x10.0, PTFE (Teflon)  Max 250C
  21033 DN50 Flange 0-ring, 65.0x10.0, FKM (Viton)  Max 200C
  21034 DN80 Flange 0-ring, 95.0x10.0, FKM (Viton)  Max 200C
TU MOUNTING  
  Indoor
  Outdoor
   
CALIBRATION CELL  
  Stainless Steel (316) For corrosive gases (except HF)
  Stainless Steel (316) For corrosive gases (except HF)
  Cal cell for O2 (Al) For non-corrosive gases
  Cal cell for HF (AI/PTFE)
MEASUREMENT CELL  
  Measurment Cell 150mm (316SS electro-polished) with sapphire window & DN50 Flange
  Measurment Cell 240mm (316SS electro-polished) with sapphire window & DN50 Flange
  Measurment Cell 50omm (316SS electro-polished) with sapphire window & DN50 Flange
  Measurment Cell 700mm (316SS electro-polished) with sapphire window & DN50 Flange
  Measurment Cell 1000mm (316SS electro-polished) with sapphire window & DN50 Flange
TRANSMISSION OUTPUT  
  Additional 4-20mA for Trans o/p
  Auxiliary board including one 4-20mA
  Second and third 4-20mA analogue output (13474 is required for this option)
ETHERNET OUTPUT  
  Ethernet Connection (without cable)
   
ADDITIONAL NETWORK CABLE  
  Network Cable 15m (including connectors) straight
  Network Cable 15m (including connectors)cross-over
TU/RU PURGING  
  None (Blanked)
  N2 Fittings (Low Level O2)
   
2nd PURGE PORT FITTING  
  Option for 2 purge fitting on each purge/alignment unit
HIGH PRESSURE WINDOW >5 BAR  
  High Pressure Window for O2 HP O2 measurement
   
ALIGNMENT TOOLS  
  Alignment jig w/target
  IR Card (not suitable for HCl, NO, Low conc CO, CO2)
   
   
PURGE GAS FILTRATION  
  Purge Gas Filter Unit
   
INTEGRATED SPAN CHECK  
  Span check (for non corrosive gases only) incl. switch box.  Check application feasability with Technical Centre before quoting.
  Fixed internal sealed cell (Laser tracking typically for "zero" type applications) Check application feasability with
Technical Centre before quoting.
  Span check with internal sealed cell. Check application feasability with Technical Centre before quoting.
   
2 YEARS SPARES KIT  
  2 years spares kit
   
CERTIFICATE OF ORIGIN  
  Certificate of origin (May be required for FAT by customer)
   
   
   
02930964A Measurment Cell 150mm (316SS electro-polished) with sapphire window & DN50 Flange
02930964B Measurment Cell 240mm (316SS electro-polished) with sapphire window & DN50 Flange
02930964C Measurment Cell 50omm (316SS electro-polished) with sapphire window & DN50 Flange
02930964D Measurment Cell 700mm (316SS electro-polished) with sapphire window & DN50 Flange
02930964E Measurment Cell 1000mm (316SS electro-polished) with sapphire window & DN50 Flange
   
   
2940A SERVOTOUGH LaserCompact  
   
02940A1 SERVOTOUGH LaserCompact
CONFIGURATION  
  Compact
AREA CLASSIFICATION  
  Safe Area
  Exn ATEX/IECEx Zone 2 Option
  CSA general purpose - Standard single path
  N. American CL 1 DIV 2
   
MEASUREMENT  
Compact monitors Measurement
   
  O2 LaserCompact Monitor
  CO LaserCompact Monitor % CO
  CO LaserCompact Monitor ppm CO
  CO2 LaserCompact Monitor % CO2
  CO2 LaserCompact Monitor ppm CO2
  NH3 LaserCompact Monitor
  HF LaserCompact Monitor
  HCl LaserCompact Monitor
  H2O LaserCompact Monitor ppm H2O
  H2O LaserCompact Monitor ppm H2O in HC
  H2S LaserCompact Monitor
  H2O LaserCompact Monitor % H2O
  CH4 LaserCompact Monitor (methane)
  HCN LaserCompact Monitor (hydrogen cyanide)
  C3H6 LaserCompact Monitor (propylene)
  C2H4O LaserCompact Monitor (ethylene oxide)
  CH2O LaserCompact Monitor (formaldehyde)
  N2O SERVOTOUGH LaserCompact Monitor (nitrous oxide)
  N2O SERVOTOUGH LaserCompact Monitor (ppm nitrous oxide)
  C2H2 ServoTough Laser Compact: Acetylene measurement
   
MEASURING RANGE  
  Please state
MEASUREMENT UNITS  
  mg/m3
  ppm
  % vol
   
DUAL MEASUREMENT  
  Not Required
  H2O dual gas Add-on
  CH4 Dual Gas Add-on
   
DUAL MEASURING RANGE  
  Please state
   
DUAL MEASUREMENT UNITS  
  mg/m3
  ppm
  % vol
  Celsius
   
   
  Gas Component 1
  Stream Comp 1 Normal Range
  Stream Comp 1 Low Range
  Stream Comp 1 High Range
  Process Dust (mg/m3)
  Process Flow (m3/h)
  Process Velocity (m/sec)
  Process Opacity (%)
  Stream Temperature (°C)
  Ambient Temperature (°C)
   
  Trans/Rec Cable 10m (5m supplied as standard)
  Trans/Rec Cable 15m (5m supplied as standard)
  Trans/Rec Cable 20m (5m supplied as standard)
  TU/RU Connecting Cable 5-20m (per metre). 5m supplied as standard.
   
  TU Optical Path Length L1 (mm)
  Stack Diameter L2 (mm)
  RU Optical Path Length L3 (mm)
   
PROCESS PRESSURE UNITS  
  mbar
  bar
   
PROCESS PRESSURE (bar)  
  Please specify
OPTICAL WINDOW PURGING  
  None (low dust)
  Instrument Air
   
   
  Fan
  N2 (low level O2)
  Steam
SUPPLY VOLTAGE  
  110Vac 50/60Hz
  220Vac 50/60Hz
SPECIAL FLANGE O-RINGS  
  DN 50 PTFE O-ring
  DN50 Viton O-ring
  DN80 Viton O-ring
HIGH TEMPERATURE APPLICATIONS  
  High temp. O2/CO2/CO applications(>700C) RU Filter mounted/tested
  High Temp O2 with Air Purge (>500C)
MOUNTING FLANGE  
  DN80/PN10 (DP Standard)
  ANSI 2"/150lbs
  ANSI 3"/150lbs
  ANSI 4"/150lbs
CALIBRATION CELL  
  Calibration Cell Stainless Steel (316)
  Calibration Cell Stainless Steel (316) For corrosive gases (except HF)
  Cal cell for O2 (Al)
MEASUREMENT CELL  
  Order measurement cell as separate item: See 02930964 measurement price list below.
  Cal cell for HF (Al/PTFE
TRANSMISSION OUTPUT  
  Addnl 4-20mA - Trans O/P
ETHERNET OUTPUT  
  Ethernet Connection (without cable)
CABLES  
  Trans/Rec Cable 10m (5m supplied as standard)
  Trans/Rec Cable 15m (5m supplied as standard)
  Trans/Rec Cable 20m (5m supplied as standard)
  Net Cable 15m Straight
2nd PURGE PORT FITTING  
  Option for 2 purge fitting on each purge/alignment unit
ALIGNMENT TOOLS  
  Alignment jig w/target
  IR Card
PURGE GAS FILTRATION  
  Purge Gas Filter Unit
   
   
   
   
2950A SERVOTOUGH LaserExact  
   
02950A1 SERVOTOUGH LaserExact
CONFIGURATION  
  MultiPass
AREA CLASSIFICATION  
  Safe Area
  CSA General Purpose
  CSA Class 1 Div 2
  Ex n ATEX Cat 3
   
MEASUREMENT  
MultiPass monitors Measurement
   
  H2S LaserExact Monitor
  O2 LaserExact Monitor
  NH3 LaserExact Monitor
  HCL LaserExact Monitor
  HF LaserExact Monitor
  CO LaserExact Monitor
  CO2 LaserExact Monitor
  CO (hi sens) LaserExact Monitor
  H2O LaserExact Monitor
  HCN LaserExact Monitor
  CH4 LaserExact Monitor
  CO2 (hi sen) ST LaserExact Monitor
  C2H2 ST LaserExact Monitor
   
OPTIONS/ACCESSORIES  
  Addnl 4-20mA - Trans O/P
  Ethernet w/o cable