SERVOTOUGH FluegasExact Comb. Analyser | |
02700D1 | |
CONTROLLER TYPE | |
GEN | Safe Area |
EU2 | Haz. Area ATEX Cat 3 |
EX2 | Haz. Area IEC Ex Zone 2 |
NA2 | N. American CL 1 DIV 2 |
SENSOR HEAD TYPE | |
GEN | Safe Area |
EU2 | Haz. Area ATEX Cat 3 |
EX2 | Haz. Area IEC Ex Zone 2 |
MINI PURGE | |
Not Required | |
MiniPurge ATEX Cat 3 / IEC Ex Zone 2 | |
Supplied by others | |
MEASUREMENT | |
Oxygen Only | |
Oxygen Only, pcb Enhanced Environmental Protection | |
Combustibles Only | |
Combustibles Only, pcb Enhanced Environmental Protection | |
Oxygen & Combustibles | |
Oxygen & Combustibles, pcb Enhanced Environmental Protection | |
COMBUSTIBLES SENSOR | High Sensitivity |
Sulphur Resistant | |
FLOW ALARM | |
Not Required | |
Safe Area | |
Haz. Area ATEX Cat 3 | |
Haz. Area IEC Ex Zone 2 | |
N. American CL 1 DIV 2 | |
SUPPLY VOLTAGE | |
110V ac | |
240V ac | |
SAMPLE PROBES | |
None | |
0.5m SS sample probe, unsupported, open ended, <700°C/1292°F | |
1.0m SS sample probe, unsupported, open ended, <700°C/1292°F | |
1.5m, SS sample probe, unsupported, open ended, <700°C/1292°F (Vertical Mount Only) | |
0.5m SS sample probe, unsupported, filtered, <700°C/1292°F | |
1.0m SS sample probe, unsupported, filtered, <700°C/1292°F | |
1.5m, SS sample probe, unsupported, filtered, <700°C/1292°F (Vertical Mount Only) | |
0.5m SS sample probe, supported, filtered, with shroud, <700°C/1292°F | |
1.0m SS sample probe, supported, filtered, with shroud, <700°C/1292°F | |
1.5m SS sample probe, supported, filtered, with shroud, <700°C/1292°F | |
2.0m SS sample probe, supported, filtered, with shroud, <700°C/1292°F | |
2.5m, SS sample probe, supported, filtered, with shroud, <700°C/1292°F | |
3.0m, SS sample probe, supported, filtered, with shroud, <700°C/1292°F | |
0.5m High Temperature Alloy, sample probe, unsupported, open ended, <1000°C/1832°F | |
1.0m High Temperature Alloy, sample probe, unsupported, open ended, <1000°C/1832°F | |
1.5m, High Temperature Alloy, sample probe, unsupported, open ended, <800°C/1472°F (Vertical Mount Only) | |
2.0m, High Temperature Alloy, sample probe, unsupported, open ended, <700°C/1292°F (Vertical Mount Only) | |
0.5m High Temperature Alloy, sample probe, unsupported, filtered, <1000°C/1832°F | |
1.0m High Temperature Alloy, sample probe, unsupported, filtered, <1000°C/1832°F | |
1.5m High Temperature Alloy, sample probe, unsupported, filtered (Vertical Mount Only) | |
2.0m High Temperature Alloy, sample probe, unsupported, filtered (Vertical Mount Only) | |
0.6m, Ceramic, sample probe, unsupported, filtered, <1500°C/2732°F **Special - Consult Servomex | |
1.1m, Ceramic, sample probe, unsupported, filtered, <1500°C/2732°F **Special - Consult Servomex | |
0.5m Ceramic, sample probe, open ended, <1750°C/3182°F | |
1.0m Ceramic, sample probe, open ended, <1750°C/3182°F | |
1.5m Ceramic, sample probe, open ended, <1750°C/3182°F (Vertical Mount Only) | |
0.5m, SS sample probe, supported, dual filtered, with shroud, <700°C/1292°F | |
1.0m, SS sample probe, supported, dual filtered, with shroud, <700°C/1292°F | |
1.5m, SS sample probe, supported, dual filtered, with shroud, <700°C/1292°F | |
2.0m, SS sample probe, supported, dual filtered, with shroud, <700°C/1292°F | |
2.5m, SS sample probe, supported, dual filtered, with shroud, <700°C/1292°F | |
3.0m, SS sample probe, supported, dual filtered, with shroud, <700°C/1292°F | |
0.5m, Hastelloy, sample probe, unsupported, open | |
1.0m, Hastelloy, sample probe, unsupported, open | |
1.5m, Hastelloy, sample probe, unsupported, open (Vertical Mount Only) | |
Non Standard sample probe - refer to Servomex | |
INTERNAL FILTER 5um | |
Fitted | |
INTERNAL FLAME ARRESTORS | |
Fitted | |
ELECTRICAL CONDUIT ENTRIES | |
3/4"NPT (O2 and COe) | |
M20 (O2 or COe) | |
M25 (O2 and COe) | |
PG13.5 (O2 or COe) | |
PG21 (O2 and COe) | |
SENSOR HEAD ENCLOSURE OPTION | |
Breather Fittings | |
Corrosive Purge Fittings | |
Hazardous Area Purge Fittings | |
Special Sensor Head Purge O2 Only - contact Servomex | |
Special Sensor Head Purge Dual - contact Servomex | |
SENSOR HEAD MOUNTING OPTION | |
Standard (4"ANSI 150lbs) | |
Probe Retention (excluding supported probes) | |
Thermal Spacer (excluding supported probes) | |
Probe Retention & Thermal Spacer (excluding supported probes) | |
High Temperature Stand Off (excluding supported probes) | |
High Temperature Stand Off & Probe Retention (excluding supported probes) | |
SENSOR HEAD ADAPTOR FLANGE OPTION | |
No Adaption (4"ANSI 150lbs) | |
3" ANSI 150lbs equivalent | |
DIN 65 equivalent | |
DIN 80 equivalent | |
JIS 65 equivalent | |
JIS 80 equivalent | |
Weld -On flange complete with studs (4" ANSI 150lbs equivalent) | |
Model 700B/N to 2700 adaptor flange (excluding High Temperature Stand Off) | |
Thermox to 2700 adaptor flange (excluding Supported Probes) | |
CONTROL UNIT MOUNTING | |
Wall Mounted | |
CONTROL UNIT ENCLOSURE OPTIONS | |
Blanking Plugs Only | |
Breather Port | |
Corrosive Purge Fittings | |
UTILITIES UNITS - SAFE | |
None | |
Air Set (Oxygen Only) | |
Air Set with Autocalibration (Single sensor) | |
Air Set with Autocalibration (Dual sensor) | |
Air Set with Blowback and Autocalibration (Single sensor) | |
Air Set with Blowback and Autocalibration (Dual sensor) | |
Air Set and Manual Calibration (Single & Dual sensor) | |
USER MANUALS | |
English | |
French (currently undergoing translation) - Please consult Servomex | |
German (currently undergoing translation) - Please consult Servomex | |
SERVICE MANUAL | |
None | |
English | |
DEFAULT SOFTWARE INTERFACE LANGUAGE | |
English | |
French | |
German | |
2930A SERVOTOUGH LaserSP | |
02930A1 | SERVOTOUGH LaserSP |
CONFIGURATION | |
Single Path | |
AREA CLASSIFICATION | |
Safe Area | |
ATEX and IECEx Cat 3 Gas (Zone 2) Cat 2 Dust (Zone 21) | |
ATEX Cat. 2G (Zone 1) | |
CSA general purpose | |
CSA Class 1, Division 2 | |
MEASUREMENT | |
Single Path monitors | Measurement |
CO SERVOTOUGH LaserSP Monitor (carbon monoxide) | |
CO SERVOTOUGH LaserSP Monitor, low level detection limit 0.3ppm (carbon monoxide) | |
CO2 SERVOTOUGH LaserSP Monitor (carbon dioxide) | |
CO2 SERVOTOUGH LaserSP Monitor<400ppm (carbon dioxide) | |
NH3 SERVOTOUGH LaserSP Monitor (ammonia) | |
HF SERVOTOUGH LaserSP Monitor (hydrogen fluoride) | |
HCl SERVOTOUGH LaserSP Monitor (hydrogen chloride) | |
H2O SERVOTOUGH LaserSP Monitor 50ppm (water) | |
H2S SERVOTOUGH LaserSP Monitor (hydrogen sulphide) | |
CH4 SERVOTOUGH LaserSP Monitor (methane) | |
HCN SERVOTOUGH LaserSP Monitor (hydrogen cyanide) | |
C3H6 SERVOTOUGH LaserSP Monitor (propylene) | |
C2H4O SERVOTOUGH LaserSP Monitor (ethylene oxide) | |
CH2O SERVOTOUGH LaserSP Monitor (formaldehyde) | |
C2H2 SERVOTOUGH LaserSP Monitor (acetylene) | |
CH3I SERVOTOUGH LaserSP Monitor (methyl iodide) | |
N2O SERVOTOUGH LaserSP Monitor (nitrous oxide) | |
N2O SERVOTOUGH LaserSP Monitor (ppm nitrous oxide) | |
MEASURING RANGE | |
Please state | |
MEASUREMENT UNITS | |
mg/m3 | |
ppm | |
% vol | |
DUAL MEASUREMENT | |
Not Required | |
H2O dual gas add-on as second gas (for HF, HCl, NH3 and CO) Note: For CO only for Temp below 200C or above 700C | |
Dual gas add-on CH4 option as second gas | |
Dual gas, add on CO2 as second gas (for CO) | |
Dual gas, add on temperature (for O2 and CO) | |
DUAL MEASURING RANGE | |
Please state | |
DUAL MEASUREMENT UNITS | |
mg/m3 | |
ppm | |
% vol | |
Celsius | |
Gas Component 1 | |
Stream Comp 1 Normal Range | |
Stream Comp 1 Low Range | |
Stream Comp 1 High Range | |
Process Dust (mg/m3) | |
Process Flow (m3/h) | |
Process Velocity (m/sec) | |
Process Opacity (%) | |
Stream Temperature (°C) | |
Ambient Temperature (°C) | |
Trans/Rec Cable 10m (5m supplied as standard) | |
Trans/Rec Cable 15m (5m supplied as standard) | |
Trans/Rec Cable 20m (5m supplied as standard) | |
TU/RU Connecting Cable 5-20m (per metre). 5m supplied as standard. | |
TU Optical Path Length L1 (mm) | |
Stack Diameter L2 (mm) | |
RU Optical Path Length L3 (mm) | |
PROCESS PRESSURE UNITS | |
mbar | |
bar | |
PROCESS PRESSURE (bar) | |
Please specify | |
OPTICAL WINDOW PURGING | |
None (low dust) | |
Instrument Air | |
Fan | |
N2 (low level O2) | |
Steam | |
SUPPLY VOLTAGE | |
110Vac 50/60Hz | |
220Vac 50/60Hz | |
24Vdc | |
HIGH TEMPERATURE APPLICATIONS | |
High temp. O2/CO2/CO applications(>700C) RU Filter mounted/tested | |
13606 High Temp O2 with Air Purge (>500C) | |
MOUNTING FLANGE | |
DN50/PN10 (SP Standard) | |
DN80/PN10, pair | |
ANSI 2"/150lbs, pair | |
ANSI 3"/300lbs, pair | |
ANSI 4" 150/300lbs, pair | |
Other (Specify) | |
SPECIAL FLANGE O-RINGS | 21031 DN50 Flange 0-ring, 65.0x10.0, PTFE (Teflon) Max 250C |
21033 DN50 Flange 0-ring, 65.0x10.0, FKM (Viton) Max 200C | |
21034 DN80 Flange 0-ring, 95.0x10.0, FKM (Viton) Max 200C | |
TU MOUNTING | |
Indoor | |
Outdoor | |
CALIBRATION CELL | |
Stainless Steel (316) For corrosive gases (except HF) | |
Stainless Steel (316) For corrosive gases (except HF) electropolished | |
Cal cell for O2 (Al) For non-corrosive gases | |
Cal cell for HF (AI/PTFE) | |
MEASUREMENT CELL | |
Order measurement cell as separate item: See 02930964 measurement price list below. | |
TRANSMISSION OUTPUT | |
Additional 4-20mA for Trans o/p | |
Auxiliary board including one 4-20mA | |
Second and third 4-20mA analogue output (13474 is required for this option) | |
ETHERNET OUTPUT | |
Ethernet Connection (without cable) | |
ADDITIONAL NETWORK CABLE | |
Network Cable 15m (including connectors) straight | |
Network Cable 15m (including connectors)cross-over | |
TU/RU PURGING | |
None (Blanked) | |
N2 Fittings (Low Level O2) | |
2nd PURGE PORT FITTING | |
Option for 2 purge fitting on each purge/alignment unit | |
HIGH PRESSURE WINDOW >5 BAR | |
High Pressure Window for O2 HP O2 measurement | |
ALIGNMENT TOOLS | |
Alignment jig w/target | |
IR Card (not suitable for HCl, NO, Low conc CO, CO2) | |
PURGE GAS FILTRATION | |
Purge Gas Filter Unit | |
INTEGRATED SPAN CHECK | |
Span check (for non corrosive gases only) incl. switch box. Check application feasability with Technical Centre before quoting. | |
Fixed internal sealed cell (Laser tracking typically for "zero" type applications) Check application feasability with Technical Centre before quoting. |
|
Span check with internal sealed cell. Check application feasability with Technical Centre before quoting. | |
2 YEARS SPARES KIT | |
2 years spares kit | |
CERTIFICATE OF ORIGIN | |
Certificate of origin (May be required for FAT by customer) | |