SERVOPRO 1440 SERIES GAS ANALYSER |
|
|
|
01440D1FTX |
FLAMMABLE/TOXIC SAMPLE ANALYSER |
|
|
SINGLE / RIGHT HAND UNIT |
|
|
Oxygen Unit, 100% FS |
|
0.25% FS Carbon Dioxide Unit |
|
0.5% FS Carbon Dioxide Unit |
|
1% FS Carbon Dioxide Unit |
|
2.5% FS Carbon Dioxide Unit |
|
5% FS Carbon Dioxide Unit |
|
10% FS Carbon Dioxide Unit |
|
25% FS Carbon Dioxide Unit |
|
50% FS Carbon Dioxide Unit |
|
100% FS Carbon Dioxide Unit |
|
1% FS Carbon Monoxide Unit |
|
2.5% FS Carbon Monoxide Unit |
|
10% FS Carbon Monoxide Unit |
|
25% FS Carbon Monoxide Unit |
|
50% FS Carbon Monoxide Unit |
|
5% FS Methane Unit |
|
25% FS Methane Unit |
|
50% FS Methane Unit |
|
100% FS Methane Unit |
|
|
LEFT HAND UNIT OF DUAL ANALYSER |
|
SINGLE UNIT |
|
|
Oxygen Unit, 100% FS |
|
0.25% FS Carbon Dioxide Unit |
|
0.5% FS Carbon Dioxide Unit |
|
1% FS Carbon Dioxide Unit |
|
2.5% FS Carbon Dioxide Unit |
|
5% FS Carbon Dioxide Unit |
|
10% FS Carbon Dioxide Unit |
|
25% FS Carbon Dioxide Unit |
|
50% FS Carbon Dioxide Unit |
|
100% FS Carbon Dioxide Unit |
|
1% FS Carbon Monoxide Unit |
|
2.5% FS Carbon Monoxide Unit |
|
10% FS Carbon Monoxide Unit |
|
25% FS Carbon Monoxide Unit |
|
50% FS Carbon Monoxide Unit |
|
5% FS Methane Unit |
|
25% FS Methane Unit |
|
50% FS Methane Unit |
|
100% FS Methane Unit |
|
BLANK PANEL |
|
|
INSTRUMENT CASE |
|
|
Single Case, Bench Top |
|
Single Case, Panel Mount |
|
Dual Case With One Unit, Bench Top |
|
Dual Case With One Unit, 19" Rack |
|
Dual Case With Two Units, Bench Top |
|
Dual Case With Two Units, 19" Rack |
|
|
MAINS LEADS |
|
|
UK Power lead (1ea) |
|
USA Power lead (1ea) |
|
EUR Power lead (1ea) |
|
Loose IEC connector (1ea) |
|
|
QUICKSTART MANUAL |
|
|
English |
|
French |
|
German |
|
|
SERVICE MANUAL |
|
|
Not required |
|
English |
|
|
|
|
|
|
01440D1STD |
STANDARD ANALYSER |
|
|
SINGLE / RIGHT HAND UNIT |
|
|
Oxygen Unit, 100% FS |
|
0.25% FS Carbon Dioxide Unit |
|
0.5% FS Carbon Dioxide Unit |
|
1% FS Carbon Dioxide Unit |
|
2.5% FS Carbon Dioxide Unit |
|
5% FS Carbon Dioxide Unit |
|
10% FS Carbon Dioxide Unit |
|
25% FS Carbon Dioxide Unit |
|
50% FS Carbon Dioxide Unit |
|
100% FS Carbon Dioxide Unit |
|
|
LEFT HAND UNIT OF DUAL ANALYSER |
|
|
SINGLE UNIT |
|
Oxygen Unit, 100% FS |
|
0.25% FS Carbon Dioxide Unit |
|
0.5% FS Carbon Dioxide Unit |
|
1% FS Carbon Dioxide Unit |
|
2.5% FS Carbon Dioxide Unit |
|
5% FS Carbon Dioxide Unit |
|
10% FS Carbon Dioxide Unit |
|
25% FS Carbon Dioxide Unit |
|
50% FS Carbon Dioxide Unit |
|
100% FS Carbon Dioxide Unit |
|
BLANK PANEL |
|
|
INSTRUMENT CASE |
|
|
Single Case, Bench Top (Feature 2 must be 00) |
|
Single Case, Panel Mount (Feature 2 must be 00) |
|
Dual Case With One Unit, Bench Top |
|
Dual Case With One Unit, 19" Rack |
|
Dual Case With Two Units, Bench Top |
|
Dual Case With Two Units, 19" Rack |
|
|
BACK PRESSURE REGULATOR |
|
|
None |
|
Fitted to Right Hand Unit Only |
|
Fitted to Left Hand Unit Only |
|
Fitted to Both Units |
|
|
MAINS LEADS |
|
|
UK Power lead (1ea) |
|
USA Power lead (1ea) |
|
EUR Power lead (1ea) |
|
Loose IEC connector (1ea) |
|
|
INTERNAL PUMP |
|
|
None |
|
Fitted to Right Hand Unit Only |
|
Fitted to Left Hand Unit Only |
|
Fitted to Both Units |
|
|
QUICKSTART MANUAL |
|
|
English |
|
French |
|
German |
|
|
SERVICE MANUAL |
|
|
None |
|
English |
|
|
FIXED VARIANTS |
|
|
|
01440D1V01 |
|
01440D1V02 |
|
01440D1V03 |
|
01440D1V04 |
|
01440D1V05 |
|
01440D1V06 |
|
01440D1V07 |
|
01440D1V08 |
|
01440D1V09 |
|
|
|
|
|
|
|
SERVOTOUGH 1800 OXYGEN ANALYSER |
|
|
|
01800B1GEN |
1800 Oxygen Analyser |
|
|
CELL AND FLOW OPTIONS |
|
|
Standard cell with viton pipework |
|
Standard cell with stainless steel pipework |
|
Standard cell with viton pipework and flow alarm |
|
Standard cell with viton pipework and AFCD |
|
Standard cell with viton pipework, BPR and AFCD |
|
Standard cell with viton pipework, AFCD and flow alarm |
|
Standard cell with viton pipework, BPR, AFCD and flow alarm |
|
Solvent resistant cell with stainless steel pipework |
|
Solvent resistant cell with Hastelloy pipework |
|
High flow standard cell with stainless steel pipework |
|
High flow solvent resistant cell with stainless steel pipework |
|
High flow solvent resistant cell with Hastelloy pipework |
|
Standard cell with stainless steel pipework and bypass |
|
Solvent resistant cell with stainless steel pipework and bypass |
|
Solvent resistant cell with Hastelloy pipework and bypass |
|
|
DISPLAY OPTIONS |
|
|
3.5 digit display |
|
4.5 digit display |
|
|
SAMPLE INLET OPTIONS |
|
|
None |
|
1/4" NPT to 6mm OD stainless steel |
|
1/4" NPT to 6mm OD Hastelloy |
|
|
SAMPLE INLET OPTIONS |
|
|
None |
|
Purge fittings |
|
Breather port |
|
|
CONDUIT ENTRY OPTIONS |
|
|
3/4" NPT |
|
M20 |
|
PG 13.5 |
|
|
MOUNTING OPTIONS |
|
|
None |
|
Panel mounted |
|
|
QUICKSTART MANUAL |
|
|
English |
|
French |
|
German |
|
Spanish |
|
Portuguese |
|
Dutch |
|
Italian |
|
Japanese |
|
Chinese |
|
|
SERVICE MANUAL |
|
|
None |
|
English |
|
|
FIXED VARIANTS |
|
|
|
01800B1GENV01 |
|
01800B1GENV02 |
|
01800B1GENV03 |
|
01800B1GENV04 |
|
|
|
|
|
|
|
|
|
SERVOTOUGH Oxy ANALYSER |
|
|
|
01910B1 |
Digital Oxygen Analyser |
OXY PACKS |
Entry Pack |
|
Hot Pack |
|
Autovalidation Pack |
|
Pressure & Flow Pack |
|
Complete Pack |
|
User Configured |
|
|
ANALYSER TYPE |
HAZ Area ATEX Cat 2 (Zone 1) |
|
IEC Ex d ia IIC |
|
CSA/North American Class 1 Div 1 & Zone 1 |
|
TIIS Ex ia d IIC |
|
|
SUPPLY VOLTAGE |
100-120Vac 50/60Hz |
|
220-240Vac 50/60Hz |
|
|
MEASUREMENT |
Standard |
|
Solvent Resist |
|
|
SAMPLING |
200ml/min (nominal) |
|
1 Litre/min |
|
|
SAMPLE HEATING |
Not Required |
|
Sample Heater - 250ml/min |
|
Sample Heater - 1L/min |
|
|
PRESSURE COMPENSATION |
Not Required |
|
Pressure Compensation |
|
Dual Pressure/Flow |
|
Pressure Compensation (Chemraz) |
|
Dual Pressure/Flow (Chemraz) |
|
|
FLOW SENSOR |
Not Required |
|
Flow Sensor |
|
Dual Pressure/Flow |
|
Flow Sensor (Chemraz) |
|
Dual Pressure/Flow (Chemraz) |
|
|
AUTO CALIBRATION |
Not Required |
|
Auto Calibration |
|
|
DIGITAL COMMS |
Modbus RTU (RS-485) |
|
Ethernet Modbus TCP |
|
|
SAMPLE INLET |
Standard 1/4" NPT(F) |
|
1/4" OD |
|
6mm OD |
|
|
BREATHER FITTINGS |
Breather Fitting |
CORROSIVE PURGE |
Corrosive/Toxic Purge |
|
|
CONDUIT ENTRY OPTIONS |
NPT (2 x 1/2" & 2 x 3/4") |
|
Metric M20 |
|
PG 13.5 |
|
|
QUICKSTART MANUAL |
English |
|
French |
|
German |
|
|
SERVICE MANUAL |
Not Required |
|
English |
|
|
FUNCTIONAL SAFETY MANUAL |
Not Required |
|
English |
|
|
|
|
|
|
SERVOTOUGH 2200 CONTROL UNIT - ZONE 2 |
|
|
|
02210A1 |
|
|
|
CONTROLLER TYPE |
|
|
ATEX Ex II 3 GD / CENELEC EEx nC [ia] IIC T4 |
|
Hazardous Area Div 2 FM Certified |
|
Hazardous Area Div 2 CSA Certified |
|
IEC Ex nCL ia IIC |
|
|
VOLTAGE |
|
|
100-120 Vac 50/60 Hz |
|
220-240 Vac 50/60 Hz |
|
|
2210 QUICKSTART MANUAL |
|
|
English |
|
French |
|
German |
|
|
SERVICE MANUAL |
|
|
None |
|
English |
|
|
ELECTRICAL ENTRY KITS |
|
|
None (standard 3/4"NPT ) |
|
Adaptor Kit - M20 |
|
Adaptor Kit - Pg 13.5 |
|
|
OPTION SLOT 1 |
|
|
None |
|
mA Output Card |
|
Relay Card |
|
Digital Input Card |
|
|
OPTION SLOT 2 |
|
|
None |
|
mA Output Card |
|
Relay Card |
|
Digital Input Card |
|
|
OPTION SLOT 3 |
|
|
None |
|
mA Output Card |
|
Relay Card |
|
Digital Input Card |
|
|
OPTION SLOT 4 |
|
|
None |
|
mA Output Card |
|
Relay Card |
|
Digital Input Card |
|
|
DATA COMMUNICATIONS |
|
|
Modbus Protocol (RS485) |
|
Ethernet Modbus TCP-IP |
|
|
ENCLOSURE OPTION |
|
|
None |
|
Breather IP66 |
|
|
MOUNTING |
|
|
Wall Mountin |
|
Panel Mounting |
|
|
2215000 |
Transducer Interface (ONLY TO BE USED IN SAFE AREAS) |
|
|
|
|
|
|
|
|
SERVOTOUGH 2200 CONTROL UNIT - EX ZONE 1 |
|
|
|
02213A1 |
|
|
|
CONTROLLER TYPE |
|
|
ATEX Ex II 2 GD/ CENELEC EEx d ia IIC T5 |
|
Hazardous Area FM Div 1 Certified |
|
Hazardous Area CSA Div 1 Certified |
|
IEC Ex d ia IIC |
|
TIIS Ex ia d IIC |
|
|
VOLTAGE |
|
|
100-120 Vac 50/60 Hz |
|
220-240 Vac 50/60 Hz |
|
|
QUICKSTART MANUAL |
|
|
English |
|
French |
|
German |
|
|
SERVICE MANUAL |
|
|
None |
|
English |
|
|
ELECTRICAL ENTRY KITS |
|
|
None (standard 3/4"NPT ) |
|
Adaptor Kit - M20 |
|
Adaptor Kit - Pg 13.5 |
|
|
OPTION SLOT 1 |
|
|
None |
|
mA Output Card |
|
Relay Card |
|
Digital Input Card |
|
|
OPTION SLOT 2 |
|
|
None |
|
mA Output Card |
|
Relay Card |
|
Digital Input Card |
|
|
OPTION SLOT 3 |
|
|
None |
|
mA Output Card |
|
Relay Card |
|
Digital Input Card |
|
|
OPTION SLOT 4 |
|
|
None |
|
mA Output Card |
|
Relay Card |
|
Digital Input Card |
|
|
DATA COMMUNICATIONS |
|
|
Modbus Protocol (RS485) |
|
Ethernet Modbus TCP-IP |
|
|
ENCLOSURE OPTION |
|
|
None |
|
Breather IP66 |
|
|
|
|
|
|
SERVOTOUGH 2200 Z1 HT OXYGEN ANALYSER TRANSMITTER |
|
|
02222A2 |
|
|
|
TRANSMITTER TYPE |
|
|
Hazardous Area ATEX Cat 2 (Zone 1) |
|
Hazardous Area FM Div 1 |
|
Hazardous Area CSA Div 1 |
|
IEC Ex ia d IIC |
|
|
VOLTAGE |
|
|
100-120 Vac 50/60 Hz |
|
220-240 Vac 50/60 Hz |
|
|
TEMPERATURE RATING |
|
|
110°C |
|
|
|
|
USER MANUAL |
|
|
English |
|
French |
|
German |
|
|
SERVICE MANUAL |
|
|
None |
|
English |
|
|
ELECTRICAL ENTRY KITS |
|
|
None (standard 3/4"NPT ) |
|
Adaptor Kit - M20 |
|
Adaptor Kit - Pg 13.5 |
|
|
INTERNAL SAMPLE FILTER |
|
|
Fitted |
|
Not required |
|
|
FLOW ALARM |
|
|
Fitted |
|
Not required |
|
|
PURGE FITTINGS |
|
|
None |
|
Corrosive Sample Purge |
|
|
|
|
|
|