04416A1 SERVOPRO NanoChrome O2 Background
  includes report software, packaging
Impurities options  
N2 Range 0-250ppb LDL 0.3ppb INJ/HC with 2 valves
Ar Range 0-250ppb LDL 0.5ppb INJ/HC with 2 valves
H2 Range 0-250ppb LDL 0.8ppb INJ/HC with 2 valves
CO Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CO2 Range 0-250ppb LDL 0.8ppb BF/HC with 2 valves
CH4 Range 0-250ppb LDL 0.8ppb BF/HC with 2 valves
CO2/CH4 Range 0-250ppb LDL 0.8ppb BF/HC with 2 valves
NMHC Range 0-250ppb LDL 0.8ppb BF with 1 valve
   
Chassis options  
Master Chassis Max. 2 channels with 4 valves
PC+ Slave chassis 2 BF/HC channels
Master +Slave1 Chassis Max. 4 channels with 8 valves
Master +Slave 1 +Slave 2 Chassis Max. 6 channels with 12 valves
Aux.oven O2 trap only for N2 measurement
   
   
Carrier Gas Helium
   
   
Power 115 VAC, 50-60 Hz
  220 VAC, 50-60 Hz
   
Gas Connectors (to match accessories fittings) 1/8" VCR
   
Serial port RS-232
   
   
Remote Support VNC
  Net Support
   
Internal Dilution System Not Required( > 1ppm)
  Required( One per Chassis)
   
   
   
04416A1 SERVOPRO NanoChrome H2 Background
  includes report software, packaging
Impurities options  
N2 Range 0-250ppb LDL 0.3ppb INJ/HC with 2 valves
Ar Range 0-250ppb LDL 0.5ppb INJ/HC with 2 valves
CO Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CO2 Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CH4 Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CO2/CH4 Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CO2/CH4/NMHC Range 0-250ppb LDL 0.5ppb BF/HC/SEL with 3 valves
   
Chassis options  
Master Chassis Max. 2 channels with 4 valves
PC+ Slave chassis 2 BF/HC channels
Master +Slave1 Chassis Max. 4 channels with 8 valves
Master +Slave 1 +Slave 2 Chassis Max. 6 channels with valves
Aux.oven H2 trap only for N2 measurement
   
   
Carrier Gas Helium
   
   
Power 115 VAC, 50-60 Hz
  220 VAC, 50-60 Hz
   
Gas Connectors (to match accessories fittings) 1/8" VCR
   
Serial port RS-232
   
   
Remote Support VNC
  Net Support
   
Internal Dilution System Not Required
  Required ( One per Chassis)
   
   
   
   
04402A1 Argon Purity Analyser Base
  includes report software, 2 SS coils tubing, packaging
   
Trace (>10 ppm), Pack 1 O2 Impurity - Enter range & LDL
  0-10ppm ≤O2 range ≤ 0-100ppm  LDL is 1.5% full scale
  H2 Impurity - Enter range & LDL
  0-10ppm ≤H2 range ≤ 0-100ppm  LDL is 1.5% full scale
  N2 Impurity - Enter range & LDL
  0-10ppm ≤N2 range ≤ 0-100ppm  LDL is 1.5% full scale
  CH4 Impurity - Enter range & LDL
  0-10ppm ≤CH4 range ≤ 0-100ppm  LDL is 1.5% full scale
  CO Impurity - Enter range & LDL
  0-10ppm ≤CO range ≤ 0-100ppm  LDL is 1.5% full scale
   
   
Trace (>10 ppm), Pack 2 Same as Pack 1 +
  CO2 Impurity - Enter range & LDL
  0-10ppm ≤CO2 range ≤ 0-100ppm  LDL is 1.5% full scale
   
Trace Exact (<10 ppm), Pack 1 O2 Impurity - Enter range & LDL
  0-1ppm ≤O2 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
Min Range 0-1 ppm H2 Impurity - Enter range & LDL
  0-1ppm ≤H2 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
  N2 Impurity - Enter range & LDL
  0-1ppm ≤N2 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
  CH4 Impurity - Enter range & LDL
  0-1ppm ≤CH4 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
   
Trace Exact (<10 ppm), Pack 2 Same as Pack 1 +
Min Range 0-1 ppm CO Impurity - Enter range & LDL
  0-1ppm ≤CO range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
   
Trace Exact (<10 ppm), Pack 3 Same as Pack 2 +
  CO2 Impurity - Enter range & LDL
Min Range 0-1 ppm 0-1ppm ≤CO2 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
   
Carrier Gas Argon
   
Power 115 VAC, 50-60 Hz
  220 VAC, 50-60 Hz
   
Gas Connectors (to match accessories fittings) 1/8" Swagelok
  1/8" VCR (if 0-1 ppm range)
   
Serial port Not Required
  RS-232
   
Remote Support VNC
  Net Support
   
Dual Inlets (sample + span, with switching) Not Required
  Required
   
Calibration using background gas Not required
  Required
   
   
   
04403A1 Helium Purity Analyser Base
  includes report software, SS liners, packaging
   
Trace (>10 ppm), Pack 1 O2 Impurity - Enter range & LDL
  0-10ppm ≤O2 range ≤ 0-100ppm  LDL is 1.5% full scale
  H2 Impurity - Enter range & LDL
  0-10ppm ≤H2 range ≤ 0-100ppm  LDL is 1.5% full scale
  N2 Impurity - Enter range & LDL
  0-10ppm ≤N2 range ≤ 0-100ppm  LDL is 1.5% full scale
  CH4 Impurity - Enter range & LDL
  0-10ppm ≤CH4 range ≤ 0-100ppm  LDL is 1.5% full scale
  CO Impurity - Enter range & LDL
  0-10ppm ≤CO range ≤ 0-100ppm  LDL is 1.5% full scale
   
Trace (>10 ppm), Pack 2 Same as Pack 1 +
  Ar Impurity - Enter range & LDL
  0-10ppm ≤Ar range ≤ 0-100ppm  LDL is 1.5% full scale
  Ne Impurity - Enter range & LDL
  0-10ppm ≤Ne range ≤ 0-100ppm  LDL is 1.5% full scale
   
Trace (>10 ppm), Pack 3 Same as Pack 2 +
  CO2 Impurity - Enter range & LDL
  0-10ppm ≤CO2 range ≤ 0-100ppm  LDL is 1.5% full scale
   
Trace Exact (<10 ppm), Pack 1 O2 Impurity - Enter range & LDL
  0-1ppm ≤O2 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
Min Range 0-1 ppm H2 Impurity - Enter range & LDL
  0-1ppm ≤H2 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
  N2 Impurity - Enter range & LDL
  0-1ppm ≤N2 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
  CH4 Impurity - Enter range & LDL
  0-1ppm ≤CH4 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
   
Trace Exact (<10 ppm), Pack 2 Same as Pack 1 +
  CO Impurity - Enter range & LDL
Min Range 0-1 ppm 0-1ppm ≤CO range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
   
Trace Exact (<10 ppm), Pack 3 Same as Pack 2 +
Min Range 0-1 ppm Ar Impurity - Enter range & LDL
  0-1ppm ≤Ar range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
  Ne Impurity - Enter range & LDL
  0-1ppm ≤Ne range < 0-10ppm  LDL is 1.5% full scale,Min.150ppb
   
Trace Exact (<10 ppm), Pack 4 Same as Pack 3 +
  CO2 Impurity - Enter range & LDL
Min Range 0-1 ppm 0-1ppm ≤CO2 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
   
Carrier Gas Helium
   
Power 115 VAC, 50-60 Hz
  220 VAC, 50-60 Hz
   
   
Gas Connectors (to match accessories fittings) 1/8" Swagelok
  1/8" VCR (if 0-1 ppm range)
   
Serial port Not Required
  RS-232
   
Remote Support VNC
  Net Support
   
Dual Inlets (sample + span, with switching) Not Required
  Required
   
Calibration using background gas Not required
  Required