Đại lý Raytek (Fluke) Vietnam, Raytek (Fluke) Vietnam,Raytek (Fluke) - ANS Vietnam,CARBON ANODE BAKE FURNACE SOLUTION,CABFR1ACF1,CABFR1BCF1

 

CARBON ANODE BAKE FURNACE SOLUTION
CABFR1ACF1   4 Type of Cable (3, 4, 6, 10 meter)
CABFR1BCF1   4 Type of Cable (3, 4, 6, 10 meter)
 INSTALLATION ACCESSORIES FOR CARBON ANODE BAKE FURNACE     
 CABINSTALL1    Carbon Anode Bake Furnace Installation Kit.  Stainless Steel hardware with quick disconnect, air purge, sight tube and 3m (10ft.) protection tube. For use with 3m fiber-optic cable.  
 CABINSTALL2    Carbon Anode Bake Furnace Installation Kit.  Stainless Steel hardware with quick disconnect, air purge, sight tube and 4m (13ft.) protection tube. For use with 4m fiber-optic cable.   
 CABINSTALL4    Carbon Anode Bake Furnace Installation Kit.  Stainless Steel hardware with quick disconnect, air purge, sight tube and 10m (30ft.) protection tube. For use with 3m fiber-optic cable.   
 XXXFRFAWCKIT     Field installable, Electronics cooling platform   
 SMART RS485 CONVERTERS:  These RS-485 to RS-232 interface converters are recommended for use with all Raytek Software Packages 
XXXUSB485   USB to RS232/422/485 converter 
 SPARE PARTS     
 XXXFR1HCF1B     Replacement/Spare fiber-optic head 
XXXFR1CB3     3m (10ft.) FR1 fiber-optic cable 
 XXXFR1CB4     Replacement/Spare 4m (13ft.) fiber-optic cable 
XXXFR1CB6     6m (20ft.) FR1 fiber-optic cable 
 XXXFR1CB10    10m (33ft.) FR1 fiber-optic cable 
BF1FRWINDOW   Sapphire protective Window mounted in Stainless Steel bezel  
RAYTX-S (Smart Series) 
RAYTX-S-LT   Low Temp: -18 to 500°C (0 to 932°F) / 8 to 14 microns, TXSLT default scaling is -18 to 500°C (0 to 932°F) and can be field set up to 0 to 1000°F), TXFLT output fixed and scaled to 0 to 1000°F, TXCLT output is fixed and scaled to -18 to 500°C
RAYTX-S-LT0   Low Temp: 0 to 500°C / 8 to 14 microns, TXCLT output is fixed and scaled 0 to 500°C (For use with TXC units only)
RAYTX-S-MT   Medium Temp: 200 to 1000°C (392 to 1832°F) / 3.9 microns, TXSMT default scaling is 200 to 1000°C (392 to 1832°F), TXFMT output fixed and scaled to 400 to 1800°F, TXCMT output is fixed and scaled to 200 to 1000°C
RAYTX-S-HT   High Temp: 500 to 2000°C (932 to 3632°F) / 2.2 microns, TXSHT default scaling is 500 to 2000°C (932 to 3632°F), TXFHT output fixed and scaled to 950 to 3600°F, TXCHT output is fixed and scaled to 500 to 2000°C
RAYTX-S-G5   Glass Surface: 250 to 1650°C (482 to 3002°F) / 5.0 microns, TXSG5 default scaling is 250 to 1650°C (482 to 3002°F), TXFG5 output fixed and scaled to 500 to 3000°F, TXCG5 output is fixed and scaled to 250 to 1650°C
RAYTX-S-P7   Thin Film Plastics (Polyester & Teflon): 10 to 360°C (50 to 680°F) / 7.9 microns, TXSP7 default scaling is 10 to 360°C (50 to 680°F), TXFP7 output fixed and scaled to 50 to 650°F, TXCP7 output is fixed and scaled to 10 to 360°C
FOCUS OPTION FOR RAYTX-S
SF   Standard Focus, (33:1 D:S for all models except HT which has 60:1)
CF1   Close Focus 1, (Not available for P7, consult factory for special G5 close focus)
CF2   Close Focus 2, (Not available for P7, consult factory for special G5 close focus)
PSF   Plastic Fresnel Lens, Standard Focus, 15:1 D:S for LT models only
    OPTION FOR RAYTX-S
IS4   Intrinsically-Safe Rating, for TXS models only
EX II 2G Ex ib IIC T4 Gb (gases/vapors)
EX II 2D Ex ibD IIIC T135°C Db (dusts)
IS4W   Intrinsically-Safe Rating for TXS including Water/Air Cooled Housing/Air Purge Collar
EX II 2G Ex ib IIC T4 Gb (gases/vapors)
EX II 2D Ex ibD IIIC T135°C Db (dusts)
IS5   Intrinsically-Safe Rating, for TXS models only, PTB-approval
EX II 2G Ex ib IIC T4 Gb (gases/vapors)
EX II 2D Ex ibD IIIC T135°C Db (dusts)
IS5W   Intrinsically-Safe Rating for TXS including Water/Air Cooled housing/Air Purge Collar, Stainless Steel
EX II 2G Ex ib IIC T4 Gb (gases/vapors)
EX II 2D Ex ibD IIIC T135°C Db (dusts)
XXXTXCERT   Calibration is traceable to the International System of Units (SI), through National Metrological Institutes such as NIST (order as a separate line item)
XXXTXACTWL   Amtir Protective Window for LT model 
XXXTXACTWM   Sapphire Protective Window for MT model
XXXTXACTWH   Glass Protective Window for HT model 
XXXTXACTWGP   Calcium Fluoride Protective Window for G5 and P7 models 
XXXTXACTWLF1   Plastic Foil Protective Window in stainless Steel frame - for use with Laser-sighted models  (includes 10 spare foils) 
XXXTWLF   10 spare plastic foils for XXXTXACTWLF1 
XXXTXACTWLS   Stainless Steel Amtir Protective Window for LT model 
NOTE:  Protective windows are shipped uninstalled from the factory. To signify "factory installed" window please add "I" to the end of the part number (e.g. XXXTXACTWL becomes XXXTXACTWLI) 
XXXTXACRCK   Remote Communications Kit for Smart Model TXS, includes HART/RS232 adapter, cables & DataTemp Multidrop software. 
XXXSYSPS   24VDC power supply (100/240),1.3 amps
RAYGPC   Remote Panel Mount  Display and Power Supply for XR Sensors  
RAYGPCM   GPC panel-mount meter with 3 A mechanical alarm relay outputs, fully isolated electrical inputs and outputs, 110/220 VAC power  
BFATXISSET   Required Complete ABB power supply, IS barrier and isolater set for Intrinsically safe TX sensors
XXXTXXACAP   Air purge collar  
XXXTXXACCA   Conduit adapter 
XXXTXXACPA   Pipe adapter (Sighting Tubes listed below can be attached to this) 
XXXTXXACMN   Mounting nut  (spare) 
XXXTXXACFB   Fixed bracket  (spare) 
XXXTXXACAB   Adjustable bracket  (spare)
XXXTXXACSB   Swivel bracket 
XXXTXXACSV   Sighting viewer setup tool  
XXXTXXACRA   Right angle mirror (for targets at right angles to sensor axis) 
XXXTXXACAFA   Adjustable Furnace Wall Mounting Assembly  
XXXTXXACFA   Wall Mount Flange Assembly  
XXXTXXACAPS   Stainless Steel Air Purge Collar