Đại lý Raytek (Fluke) Vietnam, Raytek (Fluke) Vietnam,Raytek (Fluke) - ANS Vietnam,CARBON ANODE BAKE FURNACE SOLUTION,CABFR1ACF1,CABFR1BCF1
CARBON ANODE BAKE FURNACE SOLUTION | ||
CABFR1ACF1 | 4 Type of Cable (3, 4, 6, 10 meter) | |
CABFR1BCF1 | 4 Type of Cable (3, 4, 6, 10 meter) | |
INSTALLATION ACCESSORIES FOR CARBON ANODE BAKE FURNACE | ||
CABINSTALL1 | Carbon Anode Bake Furnace Installation Kit. Stainless Steel hardware with quick disconnect, air purge, sight tube and 3m (10ft.) protection tube. For use with 3m fiber-optic cable. | |
CABINSTALL2 | Carbon Anode Bake Furnace Installation Kit. Stainless Steel hardware with quick disconnect, air purge, sight tube and 4m (13ft.) protection tube. For use with 4m fiber-optic cable. | |
CABINSTALL4 | Carbon Anode Bake Furnace Installation Kit. Stainless Steel hardware with quick disconnect, air purge, sight tube and 10m (30ft.) protection tube. For use with 3m fiber-optic cable. | |
XXXFRFAWCKIT | Field installable, Electronics cooling platform | |
SMART RS485 CONVERTERS: These RS-485 to RS-232 interface converters are recommended for use with all Raytek Software Packages | ||
XXXUSB485 | USB to RS232/422/485 converter | |
SPARE PARTS | ||
XXXFR1HCF1B | Replacement/Spare fiber-optic head | |
XXXFR1CB3 | 3m (10ft.) FR1 fiber-optic cable | |
XXXFR1CB4 | Replacement/Spare 4m (13ft.) fiber-optic cable | |
XXXFR1CB6 | 6m (20ft.) FR1 fiber-optic cable | |
XXXFR1CB10 | 10m (33ft.) FR1 fiber-optic cable | |
BF1FRWINDOW | Sapphire protective Window mounted in Stainless Steel bezel | |
RAYTX-S (Smart Series) | ||
RAYTX-S-LT | Low Temp: -18 to 500°C (0 to 932°F) / 8 to 14 microns, TXSLT default scaling is -18 to 500°C (0 to 932°F) and can be field set up to 0 to 1000°F), TXFLT output fixed and scaled to 0 to 1000°F, TXCLT output is fixed and scaled to -18 to 500°C | |
RAYTX-S-LT0 | Low Temp: 0 to 500°C / 8 to 14 microns, TXCLT output is fixed and scaled 0 to 500°C (For use with TXC units only) | |
RAYTX-S-MT | Medium Temp: 200 to 1000°C (392 to 1832°F) / 3.9 microns, TXSMT default scaling is 200 to 1000°C (392 to 1832°F), TXFMT output fixed and scaled to 400 to 1800°F, TXCMT output is fixed and scaled to 200 to 1000°C | |
RAYTX-S-HT | High Temp: 500 to 2000°C (932 to 3632°F) / 2.2 microns, TXSHT default scaling is 500 to 2000°C (932 to 3632°F), TXFHT output fixed and scaled to 950 to 3600°F, TXCHT output is fixed and scaled to 500 to 2000°C | |
RAYTX-S-G5 | Glass Surface: 250 to 1650°C (482 to 3002°F) / 5.0 microns, TXSG5 default scaling is 250 to 1650°C (482 to 3002°F), TXFG5 output fixed and scaled to 500 to 3000°F, TXCG5 output is fixed and scaled to 250 to 1650°C | |
RAYTX-S-P7 | Thin Film Plastics (Polyester & Teflon): 10 to 360°C (50 to 680°F) / 7.9 microns, TXSP7 default scaling is 10 to 360°C (50 to 680°F), TXFP7 output fixed and scaled to 50 to 650°F, TXCP7 output is fixed and scaled to 10 to 360°C | |
FOCUS OPTION FOR RAYTX-S | ||
SF | Standard Focus, (33:1 D:S for all models except HT which has 60:1) | |
CF1 | Close Focus 1, (Not available for P7, consult factory for special G5 close focus) | |
CF2 | Close Focus 2, (Not available for P7, consult factory for special G5 close focus) | |
PSF | Plastic Fresnel Lens, Standard Focus, 15:1 D:S for LT models only | |
OPTION FOR RAYTX-S | ||
IS4 | Intrinsically-Safe Rating, for TXS models only EX II 2G Ex ib IIC T4 Gb (gases/vapors) EX II 2D Ex ibD IIIC T135°C Db (dusts) |
|
IS4W | Intrinsically-Safe Rating for TXS including Water/Air Cooled Housing/Air Purge Collar EX II 2G Ex ib IIC T4 Gb (gases/vapors) EX II 2D Ex ibD IIIC T135°C Db (dusts) |
|
IS5 | Intrinsically-Safe Rating, for TXS models only, PTB-approval EX II 2G Ex ib IIC T4 Gb (gases/vapors) EX II 2D Ex ibD IIIC T135°C Db (dusts) |
|
IS5W | Intrinsically-Safe Rating for TXS including Water/Air Cooled housing/Air Purge Collar, Stainless Steel EX II 2G Ex ib IIC T4 Gb (gases/vapors) EX II 2D Ex ibD IIIC T135°C Db (dusts) |
|
XXXTXCERT | Calibration is traceable to the International System of Units (SI), through National Metrological Institutes such as NIST (order as a separate line item) | |
XXXTXACTWL | Amtir Protective Window for LT model | |
XXXTXACTWM | Sapphire Protective Window for MT model | |
XXXTXACTWH | Glass Protective Window for HT model | |
XXXTXACTWGP | Calcium Fluoride Protective Window for G5 and P7 models | |
XXXTXACTWLF1 | Plastic Foil Protective Window in stainless Steel frame - for use with Laser-sighted models (includes 10 spare foils) | |
XXXTWLF | 10 spare plastic foils for XXXTXACTWLF1 | |
XXXTXACTWLS | Stainless Steel Amtir Protective Window for LT model | |
NOTE: Protective windows are shipped uninstalled from the factory. To signify "factory installed" window please add "I" to the end of the part number (e.g. XXXTXACTWL becomes XXXTXACTWLI) | ||
XXXTXACRCK | Remote Communications Kit for Smart Model TXS, includes HART/RS232 adapter, cables & DataTemp Multidrop software. | |
XXXSYSPS | 24VDC power supply (100/240),1.3 amps | |
RAYGPC | Remote Panel Mount Display and Power Supply for XR Sensors | |
RAYGPCM | GPC panel-mount meter with 3 A mechanical alarm relay outputs, fully isolated electrical inputs and outputs, 110/220 VAC power | |
BFATXISSET | Required Complete ABB power supply, IS barrier and isolater set for Intrinsically safe TX sensors | |
XXXTXXACAP | Air purge collar | |
XXXTXXACCA | Conduit adapter | |
XXXTXXACPA | Pipe adapter (Sighting Tubes listed below can be attached to this) | |
XXXTXXACMN | Mounting nut (spare) | |
XXXTXXACFB | Fixed bracket (spare) | |
XXXTXXACAB | Adjustable bracket (spare) | |
XXXTXXACSB | Swivel bracket | |
XXXTXXACSV | Sighting viewer setup tool | |
XXXTXXACRA | Right angle mirror (for targets at right angles to sensor axis) | |
XXXTXXACAFA | Adjustable Furnace Wall Mounting Assembly | |
XXXTXXACFA | Wall Mount Flange Assembly | |
XXXTXXACAPS | Stainless Steel Air Purge Collar | |