None
  500ml Flowmeter for Module 1
  2500ml Flowmeter for Module 1
  5000ml Flowmeter for Module 1
  500ml Flowmeter for Module 2
  5000ml Flowmeter for Module 2
  500ml Flowmeter for Module 3
  2500ml Flowmeter for Module 3
  5000ml Flowmeter for Module 3
  500ml Flowmeter for Module 4
  5000ml Flowmeter for Module 4
   
FLOWMETER (RIGHT)  
  None
  500ml Flowmeter for Module 1
  2500ml Flowmeter for Module 1
  5000ml Flowmeter for Module 1
  500ml Flowmeter for Module 2
  5000ml Flowmeter for Module 2
  500ml Flowmeter for Module 3
  2500ml Flowmeter for Module 3
  5000ml Flowmeter for Module 3
  500ml Flowmeter for Module 4
  5000ml Flowmeter for Module 4
   
INTERNAL SAMPLE FILTER (fitted to front panel)  
  None
  PM/152x Sensor in Module 1
  PM/152x Sensor in Module 2
  PM/152x Sensor in Module 3
  PM/152x Sensor in Module 4
   
OIL/DUST FILTER FOR ZIRCONIA O2 704 TRACE (supplied as loose item)
  Oil/Dust Filter Zirconia O2 Module 1
  Oil/Dust Filter Zirconia O2 Module 2
  Oil/Dust Filter Zirconia O2 Module 3
  Oil/Dust Filter Zirconia O2 Module 4
   
   
EXTERNAL SAMPLE FILTER (supplied as loose items) - Not required for Zirconia O2 704 if Oil/Dust filter selected
  None
  1off
  2off
  3off
  4off
   
AUTOCALIBRATION  
  No additional hardware
  Internal Valves fitted (for PM in module 1)
  2 extra calibration relay contacts
   
EXTRA OUTPUTS  
  None
  3 extra relays and 2 extra mA
  6 extra relays and 4 extra mA
  9 extra relays and 6 extra mA
   
MOUNTING  
  Bench Mount
  19" Rack ears only
  19" Rack ears and slides, 600mm rack
  19" Rack ears and slides, 900mm rack
   
   
POWER  
  UK 170-264V AC
  USA 85-132V AC
  EUR 170-264V AC
  EUR 85-132V AC
   
QUICKSTART MANUAL  
  English
  French
  German
   
SERVICE MANUAL  
  English
   
   
OPTIONS  
  Extended chassis
   
FIXED VARIANTS  
   
04100C1V01  
04100C1V02  
04100C1V03  
   
   
04100C1V04  
04100C1V05  
   
NOTE:  
**For pricing guideline only  
Follow normal SIPS process for these modules.  
   
   
   
SERVOPRO 4200 FLAMMABLE GAS PURITY ANALYSER
   
04200C1  
   
CHASSIS TYPE  
  Short Chassis (max 2 short or 1 long sensor modules)
  Long Chassis (max 4 short or 2 long sensor modules)
   
GAS SENSOR MODULE 1  
Short Sensor Modules  
  PM O2 Control
  1520 IR, 100% CO2
  1520 IR, 50% CO2
  1520 IR, 25% CO2
  1520 IR, 10% CO2
  1520 IR, 5% CO2
  1520 IR, 2.5% CO2
  1520 IR, 1% CO2
  1521 IR, 100% CH4
  1521 IR, 50% CH4
  1521 IR, 25% CH4
  1521 IR, 5% CH4
  1522 IR, 50% CO
  1522 IR, 25% CO
  1522 IR, 10% CO
Long Sensor Modules  
  1520 IR, 5000vpm CO2
  1520 IR, 2500vpm CO2
  1522 IR, 2.5% CO
  1522 IR, 1% CO
  GFX CO 0-50/500vpm
  GFX CO2 0-5/100vpm
  GFX N2O 0-50/500vpm
  GFX CH4 0-50/500vpm
  **Simplified SIPS GFX CO 0-100/1000vpm**
  **Simplified SIPS GFX CO 0-500/5000vpm**
  **Simplified SIPS GFX CH4 0-100/1000vpm**
   
GAS SENSOR MODULE 3  
  None
Short Sensor Modules  
  PM O2 Control
  1520 IR, 100% CO2
  1520 IR, 50% CO2
  1520 IR, 25% CO2
  1520 IR, 10% CO2
  1520 IR, 5% CO2
  1520 IR, 2.5% CO2
  1520 IR, 1% CO2
  1521 IR, 100% CH4
  1521 IR, 50% CH4
  1521 IR, 25% CH4
  1521 IR, 5% CH4
  1522 IR, 50% CO
  1522 IR, 25% CO
  1522 IR, 10% CO
Long Sensor Modules  
  1520 IR, 5000vpm CO2
  1520 IR, 2500vpm CO2
  1522 IR, 2.5% CO
  1522 IR, 1% CO
  GFX CO 0-50/500vpm
  GFX CO2 0-5/100vpm
  GFX N2O 0-50/500vpm
  GFX CH4 0-50/500vpm
  **Simplified SIPS GFX CO 0-100/1000vpm**
  **Simplified SIPS GFX CO 0-500/5000vpm**
  **Simplified SIPS GFX CH4 0-100/1000vpm**
   
SAMPLE SYSTEM FOR MODULE 1  
  Flow Driven PM
  Flow Driven 152x series
  Flow Driven GFX
  Pressure Driven PM
  Pressure Driven 152x series
  Pressure Driven GFX
   
SAMPLE SYSTEM FOR MODULE 3  
  None
  Flow Driven PM
  Flow Driven 152x series
  Flow Driven GFX
  Pressure Driven PM
  Pressure Driven 152x series
  Pressure Driven GFX
   
GAS SENSOR MODULE 2