Headquarter Schwäbisch Hall
|
We have been designing and producing electronic devices in Schwaebisch Hall for more than 40 years. Our first design was a Thermistor-Relay. Since this time, our range of products has enlarged continually. For instance we have devices that communicate via Internet. Our range of products has five focuses:
There are Temperature-Relays with Sensors. on the one hand. In this group of products, we are still producing our first "baby", the Thermistor-Relay. These devices monitor temperatures in motors, transformers or plants with sensors Pt 100 (RTD), PTC-Thermistors of Thermocouples.
The second focus are devices for monitoring grids. They monitor phase, voltage, current and frequency in electric plants. Space-saving Electronic Current-Transformers capture the current-flow in a conductor.
Our Digital Panelmeters for measuring various signals are the third group. They are used where measured values shall be displayed. Alarm-outputs and integrated measuring-transducers expand the scope of applications.
The forth group are Switching Relays and Controls. Especially to be mentioned are controls for suction plants, speed monitors or level-relays for conductive liquids.
Measuring Transducers for temperature and electric values like AC and DC voltage or current or resistance complete our range of products.
Besides that we deal with special assignments and offer our customers the development and production of special solutions, customized for their application.
|
Pt 100-Temperature Relays |
|
|
|
|
EC-Declaration of Conformity Temperature Relays for Pt 100 |
|
|
|
|
|
monitor and regulate temperatures. Up to 6 sensors, 6 adjustable switching points, digital display and analogue outputs open a multiple range of applications for the user. |
|
|
|
|
|
|
|
|
|
Temperature Relays for Pt 100-Sensors, 1 Sensor |
|
|
|
|
|
|
|
TR111V |
1 Sensor, 1 adjustable limit, 1 Relay, 3 Measuring-ranges
|
|
|
|
|
|
|
|
|
|
|
|
Temperature Relays for Pt 100-Sensors, 1 Sensor, Digital Display
|
|
|
|
|
|
|
|
TR122D |
1 Sensor, 2 adjustable limits, 2 output relays, Digital Display
|
|
|
|
|
|
|
TR122 DA |
1 Sensor, 2 adjustable limits, 2 output relays, Digital Display, current output 0/4...20 mA
|
|
|
|
|
|
|
|
Temperature-Relays for Pt 100-Sensors, 2 Sensors, 2 Relays, Digital Display
|
|
|
|
|
|
|
|
TR210 |
2 sensors, 2 measuring inputs Pt 100/Pt 1000, thermocouples, 0/4...20 mA/0...10V, display 4 digits, 2 relay outputs, 2-4 limits, scaleable analog output (measuring-transducer) |
|
|
|
UL-E337414 |
|
|
|
|
|
|
|
Temperature-Relays for Pt 100-Sensors, 3 Sensors, Digital Display
|
|
|
|
|
|
|
|
TR250 |
3 sensors (Pt 100, Pt 1000, PTC, KTY), 3 adjustable limits, 3 relays
UL-E337414
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Temperature-Relays for Pt 100-Sensors, 4 Sensors, Digital Display
|
|
|
|
|
|
|
|
|
|
4 Sensors,
4 adjustable limits,
4 Relays,
2 analog outputs
with input for USB-stick
UL-E337414
|
|
|
|
|
4 sensor-inputs Pt 100 (RTD),
4 alarms/relays,
for Dry Transformers with integrated monitoring of temperature of core,
easy programming with 4 preset programs,
housing fo panel-mount,
Interface RS 485 (option)
|
|
|
|
|
|
|
|
|
|
Temperature-Relays for Pt 100-Sensors, 6 Sensors, Digital Display
|
|
|
|
|
|
|
|
TR600 |
6 Sensors
6 Relay outputs
2 Analog outputs
Interface RS 485
Digital Display |
|
|
|
UL-E337414 |
|
|
|
|
|
|
|
Temperature-Relays for Pt 100-Sensors, 12 Sensors, Digital Display, Interface RS 485
|
|
|
|
|
|
|
|
TR1200 |
12 inputs Pt 100 (RTD)
interface RS 485 with modbus RTU and ZIEHL-protocol
UL-E337414 |
|
|
|
|
|
|
|
|
|
|
|
|
TR1200IP |
12 inputs Pt 100 (RTD)
Readout of temperatures via Ethernet
Protocols modbus and ZIEHL-standard |
|
|
|
Web-IO Universal-Relay, 8 Sensor-Inputs
|
|
|
|
TR800Web |
8 Measuring inputs Pt 100/1000, KTY, Thermocouples and DC 0/4-20 mA, 0-10 V
4 Alarm-Relays
in browser via Internet/Intranet easily operable:
- Display and query of measured values
- Configuration of inputs and alarms
- alarms with e-mail
- Logging of values and alarms
UL-E337414
|
|
|
|
|
Wireless Temperature-Relay, 6 Sensors, Digital Display
|
|
|
|
|
|
|
|
WR250 |
Wireless Temperature-Relay for High-voltage Transformers,
receiver up to 6 sensors of Wireles-Sensors type WS Pt 100 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
WSPt100 |
Wireless Temperature-Sensor for High-voltage Transformers |
|
|
|
|
|
Safety Temperature Limiter |
|
|
|
|
|
|
STR100 |
monitors together with Temperature-Sensors for Pt 100 temperatures in applications, for which a monitoring with increased security safety category 3 according to EN 954-1 is required.
For example industrial furnace plants, Dyeing machines, Thermal oil plants.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Mains Monitoring |
|
|
|
EC-Declaration of Conformity Mains Monitoring |
|
|
|
|
|
|
|
|
Phase-monitor Relays |
|
|
|
protect machines and systems from damage caused by asymmetry in 3-phase power-systems. Monitoring of phase sequence protects against unintentional reverse running of electric motors |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PS2DK |
Phase asymmetry monitor |
|
|
PSSW1 |
Phase sequence/ Over- and Undervoltage monitor |
|
|
DRR10 |
Phase-Sequence Relay for 3-phase networks, automatic change of wrong phase sequence, max. 16 A
EC-Declaration of Conformity DRR |
|
|
|
|
|
DRR20 |
Phase-Sequence Relay with monitoring of Voltage and Asymmetry |
|
|
COSFI100V |
Load and Current Monitor for over- and underload at electric motors. Monitoring of current-direction at generators |
|
|
|
Current Relays (current on/off) for current recognition |
|
|
|
|
|
|
|
|
|
in OR-circuits recognize when there is a AC-current in 1 of up to 12 monitored lines and switch on for instance a central suction system. Current relays in AND-circuits only switch on when
there is a AC-current in all 3 monitored lines and report for instance a break of a phase. |
|
|
|
|
|
|
|
|
STW2V |
Current-Detection AC/DC with Current-Sensor S1 |
|
|
|
|
|
|
STW1K |
AC-recognition, OR-circuit, 1-8 transformers |
|
|
STW12 |
AC-recognition, OR-operation, 12-channel individual evaluation |
|
|
STW12V |
AC-recognition, OR-circuit, 1-12 transformers, adjustable |
|
|
|
|
|
|
|
|
|
STW20K |
AC-Erecognition, AND-circuit, 3 inputs, Housing design K for mounting on 35mm-rail or with screws M4 |
|
|
STW20V |
AC-Erecognition, AND-circuit, 3 inputs, Housing design V for mounting on DIN-rail or wall-mount |
|
|
|
|
|
|
STWA1
STWA1H |
Current transformer for current relays for current recognition |
|
|
|
Electronic-current-transformers |
|
|
|
EC-Declaration of Conformity STWA |
|
|
|
|
|
|
|
|
with built-in electronics can be directly connected to digital or analog inputs of PLCs
- monitoring current ON/OFF (adjustable)
- measuring transducers with analog outputs 0/4 - 20 mA or frequency 0,5 - 20 Hz. |
|
|
|
|
|
|
|
|
|
|
|
|
|
Current Sensor S1 |
AC/DC-currents app. 5 A / adjustable 5-30 A |
|
|
|
|
|
|
|
|
|
STWA1S |
> 2 A, Open-collector-output |
|
|
STWA1SH |
> 2 A, Open-collector-output |
|
|
|
|
|
STWA1SEH |
Switching points adjustable, 2-10 A, LED |
|
|
STWA1AH |
Measuring transducer AC 0-15 A -> DC 0-20 mA |
|
|
STWA2AH |
Measuring transducer AC 0-20 A / 0-100 A -> DC 4-20 mA |
|
|
STWA1FH |
Measuring transducer AC 0-20 A -> 0,5-20 Hz, Open-collector-output |
|
|
STWA1LH |
AC-Electronic-current-transformer with switching output AC 230 V |
|
|
|
Current Relays (adjustable) |
|
|
|
|
|
|
|
|
|
for monitoring DC- and AC-currents. Versions with up to 3 measuring-inputs and up to 2 switching points cope with various applications. In combination with external transformers or shunts, nearly any level of current can be monitored. |
|
|
|
|
|
|
|
|
STW1000V2 |
DC-Limit-value Relay for standard signalse, DC 0/4-20 mA, 0/2-10 V |
|
|
|
|
|
|
TR210 |
DC universal Limit-value Relay
2 inputs 0/4-20 mA and 0-10 V,
2 relay-outputs,
digital display,
analog output scaleable (Measuring-transducer) |
|
|
|
|
|
STW1000 |
AC and DC current, AC/DC 0,1-10 A, 6-60 mV with external shunt, over- and under-current |
|
|
STW200 |
Monitoring of LED-Lamps or Light-bulbs in obstacle lights |
|
|
|
|
|
|
WS |
Winding current transformers |
|
|
AS |
Plug-in current transformers |
|
|
|
Frequency- and Speed-Relays |
|
|
|
|
|
|
|
|
|
|
|
FR1000 |
Monitoring range 5...99.999 MIN -1
Frequency 10...500 Hz, Resolution of display 0,01 Hz
Measuring Inputs AC 20-440 V
2 limits
2 relays
Universal supply AC/DC 24-240 V |
|
|
FRMU1000 |
see FR1000,
with integrated Measuring-transducer
scaleable analog output |
|
|
|
|
|
UFR1000 |
Monitoring of Frequency and Voltage with integrated monitoring of Vector-step
For application at solar plants, in block power heating stations or general monitoring of AC-networks-Quality
Typ-Prüfschein UFR 1000 100 ms Standard
Typ-Prüfschein UFR 1000 50 ms
EC Declaration of conformity |
|
|
|
|
UFR1001 |
same as UFR1000, additionally alarm counter and sealable |
|
|
|
Current Relay for Photovoltaic-Systems |
|
|
|
|
|
|
|
|
|
Monitoring of Function at Photovoltaic-Systems, protection from downtimes |
|
|
|
|
|
SolarYes |
Monitoring of Failure at Inverters
8 Inputs |
|
|
|
|
|
|
Digital Measuring Instruments MINIPAN |
|
|
|
EC-Declaration of Conformity MINIPAN Digital Panelmeters |
|
|
|
We supply digital measuring-instruments in various designs.
Measuring-inputs are available for DC and AC current and voltage, Pt 100-sensors (RTD), KTY 83/84, Thermocouples and resistance. Further options are 2 switching-points and analog outputs. These options allow a wide variety of applications. The red LED-Displays are exceptionally rich in contrast can therefore be read in bright surroundings and from awkward angles. |
|
|
|
|
|
|
MINIPAN 300 |
|
|
|
Panel-mount 36 x 72 mm, 4-digits |
|
|
|
|
|
|
|
|
MINIPAN 350V und 352V |
|
|
|
|
Switch gear-cabinet-mount, 4-digits |
|
|
|
|
with alarms/relays |
|
|
|
|
|
|
|
|
MINIPAN 352P |
|
|
|
|
Panel-mount 72 x 72 mm, 4-digits |
|
|
|
|
with alarms/relays |
|
|
|
|
|
|
|
|
MINIPAN SE352 |
|
|
|
|
Panel-mount 48 x 96 mm, 4-digits |
|
|
|
|
with alarms/relays |
|
|
|
|
|
|
|
|
Measuring Point Change-over-switches |
|
|
|
Vibrator Controls |
|
|
|
|
|
|
|
|
|
triggering of vibrators for the cleaning of filters in suction plants. Addition of the run times of up to 3 suction motors and variable vibrating-programs with interval and continuous vibration provide for an optimal cleaning result. |
|
|
|
|
|
|
|
|
|
|
|
|
RS1K |
Vibration Control with adjustable signal delay and programs |
|
|
|
|
|
RSP1 |
Vibration controls increase with run time addition for the suction motor and programable vibration programs. |
|
|
|
Frequency- and Speed Relays |
|
|
|
|
|
|
|
|
|
|
|
FR1000 |
Measuring-input speed: 2-/3-wire, PNP/NPN, 5...99.999 IPM
Measuring-input frequency 10...500 Hz resolution 0.01
Measuring-inputs AC 20-440 V
2 limits
2 relays
Universal supply AC/DC 24-240 V
|
|
|
FRMU1000 |
same as FR 1000,
additionally with integrated measuring-transdcucer
and scaleable analog output |
|
|
|
|
|
|
|
|
|
|
|
|
Inductive Proxmity Sensor IG2 for Speed Relays FR/FRMU1000 |
|
|
|
|
Impulsgeber IG2 |
M12x1, length: 50 cm, 3-wire PNP, max. 48.000 IPM. |
|
|
|
Level Relays |
|
|
|
|
|
|
|
|
|
monitor the level of leading liquids. They are used e.g. as no-load operation protection or for the automatic draining or filling of containers . |
|
|
|
|
|
|
|
|
|
|
|
|
Electrodes NE1 and NE2 |
Level Electrodes |
|
|
|
|
|
NS1 |
2 Electrodes, impact resistant plastic housing |
|
|
|
|
|
NS20K |
2 or 3 electrodes
MIN/MAX-control
protection from rumig dry or over flow
supply voltage AC/DC 24-240 V |
|
|
NS 20 |
same as NS 20 K
but housing for mounting in fuse-boxes |
|
|
|
|
|
NS43 |
5 electrodes for MIN/MAX control and overflow/unlubricated operation protection |
|
|
NS43V |
5 electrodes for 6 different programs, universal supply AC/DC 24-240 V |
|
|
|
Twilight Switches |
|
|
|
|
|
|
|
|
|
in connection with LF5 they switch on a lightning when ambient light is decreasing |
|
|
|
|
|
|
|
|
|
|
|
|
DS6 |
Switching-limit adjustable app. 10-100 LUX
Switching-delay adjustable 0,2-10 sec
1 Relay
durable housing with enclosure IP 54.
|
|
|
|
|
|
DS6V |
same as DS 6 additionally
Hysteresis adjustable 5-50%
Switching-delay ON/OFF adjustable 0-60 sec
Switching-on-hold adjustable 0-12 hours
2 Relays
Universal power supply AC/DC 24-240 V
housing for rail- or wall-mount
|
|
|
|
Watchdog-Time-Relay |
|
|
|
|
|
|
|
|
|
Monitoring of processors in press controls on clock pulse failure. |
|
|
|
|
|
|
|
|
|
|
|
|
WD100V |
|
|
for Temperature Pt 100 |
|
|
|
|
|
|
|
|
|
protect machines and systems from damage caused by asymmetry in 3-phase power-systems. Monitoring of phase sequence protects against unintentional reverse running of electric motors |
|
|
|
|
|
|
|
|
|
|
|
The transducer for motor protection TMU 300 selects the hottest temperature of 3 connected sensors and transduces it into a signal 4-20 mA.
It is supplied by a loop 4-20 mA and needs only 2 lines. |
|
|
|
|
|
|
TMU300 |
sealed-in electronics for temperatures up to 85°C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TMU100V |
Sensor-input 2- or 3-wire with monitoring of break,
Measuring range -199...+800 °C, free selectable
Easy programming of Zero and FullScale
Analog output 0/4-20 mA
Analog output 0-10 V
Universal supply AC/DC 24-240 V
Housing for DIN-rail- or wall-mount
mounting height 55 mm, 70 mm wide |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
for Temperature and DC-current / voltage
|
|
|
|
|
|
|
|
|
|
|
TR210 |
monitoring of differences in temperature
2 Sensors Pt 100 (RTD), Pt 1000
Thermocouples type B, E, J, L, N, R, S, T
Inputs 0/4-20 mA und 0-10 V
2 Relays
digital display
scalable analog output (Measuring transducer) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MU1000K |
Universal Measuring-Transducer Pt 100 (RTD), DC-current and voltage, insulation-amplifier
Potential separation between inputs and outputs
Pt 100, 3-wire, -200...+800 °C
Ready-configured zeros and spans
Easy individual balance by pressing a button
Current inputg DC 0/4 - 20 mA
Voltage input DC 0/2-10 V
Output sinals DC 0/4 - 20 mA, 0/2 - 10 V
alle Ein-/Ausgänge in 1 Gerät
Universal-Versorgungsspannung AC/DC 24-240 V |
|
|
|
for DC-Current / Voltage (Insulating-amplifier) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MU100U |
Universal Insulating-amplifier
Potential separation between inputs and outputs
Current input DC 0 - 20 mA
Voltage input DC 0 - 10 V
Output signals DC 0/4 - 20 mA, 0 - 10 V
Offset signals 4 - 20 mA can be compensated by the user
1 device for all applications
Universal supply voltage AC/DC 24-240 V
|
|
|
|
|
|
|
|
|
|
|
MU1001K |
Universal Measuring-transducer for DC-voltages
Potential separation between inputs and outputs
Voltage-inputs:
DC 0-10 V
DC 0-300 mV for current measuring with shunt (60/150/300 mV pre-set)
DC 0-300 V can be compensated by the user (20/50/100/200/300 V pre-set)
Zeros and Fullscales freely selectable
Output signals DC 0/ -20 mA, 0-10 V
1 device for all applications
Universal supply voltage AC/DC 24-240 V |
|
|
|
|
|
|
|
|
for AC-Current |
|
|
|
|
|
|
|
|
|
Electronic Current-transducers |
|
|
|
|
|
|
|
|
|
|
|
STWA1AH |
Input AC 0...15 A, output DC 0...20 mA |
|
|
STWA2AH |
Input AC 0...20/100 A, output DC 4...20 mA |
|
|
STWA1FH |
Input AC 0...20 A, output frequency 0,5...20 Hz |
|
|
|
for Potentiometers |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MU100W |
Connection of a potentiometer 0...500 Ω bis 0...10 kΩ
Zero adjustable 0...40 %
FullScale adjustable 60...100 %
Easy adjusting by pressing a button
Analog output 0/4-20 mA, Analog output 0-10 V
Universal supply AC/DC 24-240 V
Housing for DIN-rail or wall-mount, 70 mm wide, mounting height 55 mm |
|
|
|
|
|
|
|
|
|
|
|
for Resistance |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TR122DA |
Input resistance 0...850 Ω
programmable analog output 0/4-20 mA
Digital display
2 limits
Universal supplyl AC/DC 24-240 V |
|
|
|
|
|
|
|
|
|
|
|
Accessories for Measuring-transducers |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
STW1000V2 |
Limit value-switch for standard signals, DC 0/4-20 mA, 0/2-10 V |
|
|
|
|
|
|
|
|
|
Measuring-point change-over-switch |
|
|
|
|
|
|
|
|
MUM8 |
for the link up to 8 measuring points to an evaluation unit.
The inputs can be selected over 3 bits in the BCD code, e.g. with a SPS. additionally are possible an automatic operation. |
|
|
|
|
|
|
|
|
MUM16 |
for the link up to 16 measuring points to an evaluation unit.
The inputs can be selected over 4 bits in the BCD code, e.g. with a SPS. additionally are possible an automatic operation. |
|