• Ozone monitoring in gases
  • Measuring principle according to DIN 19627 and IOA at 254 nm
  • Display in mg/m3 or % wt.
  • Special measuring cells for various concentration ranges
  • Possibility to connect external pressure and temperature sensor
  • Dual-beam measurement for high stability
  • Fast and simple verification with control unit

The Ozone meter for gases measures the ozone concentration according to standard DIN 19627 and the IOA (International Ozone Association) at a wavelength of 254nm. According to these standards, the extinction coefficient is 3024 l/mol cm. Therefore, the ozone measurement can be regarded as an absolute measurement requiring no calibration with ozone. Special measuring cells with different path-lengths cover measuring ranges for low as well as high concentrations. The concentration readings (e.g. in g/m3) are valid for the pressures and temperatures prevailing during measurement. For the conversion to standard conditions, an external pressure and temperature sensor can be connected to the operating unit, die calculation is then automatically done within the instrument. For inspecting the instrument, checking units on the basis of reference filters can easily be inserted. Operation is done intuitive using the intelligent control system SICON via touch screen technology and colour display. Values, graphs, alarm and status messages can be presented. An internal data logger allows recalling and displaying measured data from the last 32 days. A variety of analogue and digital interfaces allows smooth system integration and control.

Measuring principle

Absorption

Nominal range

0 .. 300 g/m3

Resolution

1 mg/m3

Measuring wave length

254 nm

Enclosure

ANSI 304

Protection

IP65

Flow cell material

ANSI 316L

Power input

21 W

Weight

4.3 kg

Ambient environment

-20 .. + 50°C

Maximum service altitude

3,000 m above sea level

Power supply

85 .. 264 V / 47 .. 440 Hz
24 VDC

Wavelengths UV

254 nm

Units

mg/m3, %wt.

Linearity

superior to ±0.5% transmission

Lowest measuring range 0-0.1 g/Nm3
Highest measuring range 0-300 g/Nm3
Applications in Drinking Water Treatment
Machine and Metal Industry
Pulp / Paper Industry
Ozone in Air or Oxygen (O2)
Lowest measuring range 0-0.1 g/Nm3
Highest measuring range 0-300 g/Nm3
Applications in Drinking Water Treatment

 

 

Industry Measuring Point

Drinking Water Treatment

Ozone Generator Monitoring
Ozone in Air or Oxygen (O2)

Machine and Metal Industry

Ozone Generator Monitoring

Pulp / Paper Industry

Ozone Generator Monitoring