• Designed for the construction of scales in the medical equipment and batching systems 
  • ATEX (option)
  • 3000 Divisions OIML R60 approved
  • Made of stainless steel
  • IP68 Protection (EN 60529)
  • Maximum size of the plate 600 x 600 mm (800 x 800 for capacity 250 and 400 kg)

 

Electrical Connection
+Excitation Green
-Excitation Black
+Signal Red
-Signal White
+Sense Blue
-Sense Yellow
Shield Cable Shield
 

TECHNICAL CHARACTERISTICS 190

Rated load (R.L.): 15, 20, 30, 50, 75, 120, 200, 250, 350, 400 Kg
Combined Error: < ±0.017% of R.O.
Repeatability: < ±0.010% of R.O.
Creep (20 minutes): < ±0.016% of R.L.
Safe overload: 150% of R.L.
Ultimate overload: 200% of R.L.
Recommended input: 5÷15 Vdc/Vac
Input resistance: 400 ± 20 Ohm
Output resistance: 350 ± 3 Ohm
Insulation resistance: > 5000 M Ohm
Rated output (R.O.): 2 ± 10% mV/V
Zero balance: < ±2% of R.O.
Temperature range: -20 ÷ +50 °C
Compensated Temperature Range: -10 ÷ +40 °C
Temperature effect on zero balance: < ±0.01% R.O./5°K
Temperature effect on output: < ±0.006% on output/5°K
Max load deflection: 0.3÷0.5 mm
Accuracy class: 3000 n.OIML
Degree of protection: IP68
Electrical connection: 4 conductors shielded cable; length 3 m
Material: Stainless steel
 

 
 

Accessories are not to be considered included in the price of each product.
All the above is purely illustrative and not to be understood demanding towards Pavone Sistemi