The F741-C is a high-noise-resistant weighing indicator by which stable indicated values can be obtained. Compatible with a fieldbus (PROFIBUS), and serial and analog outputs, it can be combined with a wide variety of plant devices.

Analog section
Excitation voltage DC10V±5% Output current: within 120mA
Remote sense type (Up to four 350Ω load cells can be connected in parallel.)
Signal input range -0.2 to 2.2mV/V
Zero adjustment range Automatic adjustment by digital operation
0 to 2.0mV/V
Span adjustment range Automatic adjustment by digital operation
0.3 to 2.0mV/V
Minimum input sensitivity 0.3μV/count
Accuracy Non-linearity: within 0.01%/FS
Zero drift: within 0.2μV/℃ RTI
Gain drift: within 15ppm/℃
Analog filter Bessel type low-pass filter (-12dB/oct) Cutoff frequency 2Hz
A/D converter Conversion rate: 100 times/sec. (Internal sampling 3200 times/sec.)
Conversion resolution: 24bit (binary)
Minimum indication resolution 1/10000
Secondary calibration Equivalent input calibration
Minimum indication resolution for secondary calibration 1/1000 (ordinary temperature)