Beijer Vietnam,Tần số biến tần BFI-P2-24-0095-3F42-MN Beijer

Biến tần BFI P2, IP20
Có sẵn lên đến 250 kW
Dễ sử dụng
Nhỏ gọn và mạnh mẽ

BFI-P2-24-0095-3F42-MN

Article number 60203

  • Output power 4.0 kW

  • Output 3x400 VAC, 9.5 A

  • Input voltage 3x380-480 VAC

  • IP20

General description

Article number

60203

Warranty

2 year

Mechanical

IP class

IP20

Physical size

Size 2

Measurements (H x W x D)

221 mm x 110 mm x 185 mm

Weight

1.8 kg

Typical power loss at rated power

2 % of rated power

Main switch

No

Built in Main switch, control switch and potentiometer

No

Conformal coated PCBs

Yes, IEC 60721-3-3, 3S2/3C2

Output ratings

Output voltage

3 x 400 VAC

Rated motor current

9.5 A

Overload capacity

150% for 60 seconds, 200% for 4 seconds

Motor power

4.0 kW

Output frequency

0 – 500Hz, 0.1Hz resolution

Supported motor types

3 phase AC induction (IM), AC permanent magnet (PM), Brushless DC (BLDC), Synchronous reluctance (SynRM)

Built-in brake transistor

Yes

Regenerative capacity

100 % ED

Input ratings

Supply voltage

380 – 480VAC ± 10%

Voltage fluctuations

+/- 10%

Phase imbalance

3% maximum allowed

Displacement factor

> 0.98

Supply frequency

48 – 62Hz

Power cycles

120 per hour maximum, evenly spaced

Control specification

Control modes

V/F Voltage Vector, Energy Optimised V/F, Sensorless Vector Speed Control, Sensorless Vector Torque Control, Synchronous Reluctance Motor Control, Brushless DC Motor Control, Closed Loop (Encoder) Speed Control, Closed Loop (Encoder) Torque Control, Open Loop PM Vector Control

Current/torque limitation

Torque and current limitation

PWM frquency

4-32 kHz effective

Stopping mode

Ramp to Stop: User Adjustable 0.01 – 600 seconds, Fast stop, Coast to Stop

Braking

Motor Flux Braking, Built-in Braking Transistor

Skip frequency

Yes

Analog setpoint control

0 to 10V, 10 to 0V, −10 to 10V, 0 to 20mA, 20 to 0mA, 4 to 20mA, 20 to 4mA

Digital setpoint control

8 fixed speeds, Motorised Potentiometer, Internal PLC, Keypad, Modbus RTU, CANopen, Optional: PROFIBUS DP, DeviceNet, EtherNet/IP, EtherCat, PROFINET, Modbus TCP, CC-Link

Communication

Modbus RTU

Yes, 9.6 - 115.2 kbps (8N1, 8N2, 8E1, 8O1)

BACnet MS/TP

No

Modbus TCP

Yes, external option

Ethernet IP

Yes, external option

EtherCat

Yes, external option

Profinet IO

Yes, external option

Profibus DP(DPV1)

Yes, external option

Device Net

Yes, external option

CC-Link

Yes, external option

CAN open

Yes, 125-1000 kbps

Display

Programmable display

Yes

Multi language OLED display

TFT Display

External OLED display

Yes, TFT Display

LED display

No

HVAC

PID-control

Yes with sleep/wake up functionality

Spin start

Yes

Pump dry protection

No

Pump prime and burst protection

No

Stir function

No

Motor pre-heat

No

Broken impeller and broken belt detection

No

Automatic cleaning for pumps

No

Bypass control

Yes

Fire mode

No

Control terminals

Power supply

100 mA @ 24 VDC, 20 mA @ 10 VDC

Inputs

5 in total, 3 Digital, 2 Analog or Digital, selectable

Digital inputs

10-30 V DC, PNP, Response time: < 4 msec, Internal or external supply

Analog inputs

Resolution:12 bit, Response time: <4 msec; Accuracy: <± 2% of full scale, Adjustable scaling

Outputs

4 total, 2 relays, 2 analog or digital

Digital transistor outputs

24VDC/20 mA, Internal supply

Relay outputs

Maximum Voltage: 250 VAC, 30 VDC Switching Current Capacity: 5A AC, 5A DC

Analog outputs

0 to 10 Volt, 0 to 20mA, 4 to 20mA

Safety inputs

2

Extra IOs

Yes, internal option

Control features

Speed control Master/slave

Yes, Master and slave

Modbus master functionality

Yes, Master and slave

Advanced hoist control

Yes

Built-in PLC

Yes

Standard compliances

Low voltage directive

2014/35/EU

EMC directive

2014/30/EU

Conformance

CE, UL, cUL

Machine directive

2006/42/EC

Marine approvals

No

Safe torque OFF

Cat 3/PL"d" According to ISO 13849-1, SIL CL 2 According to EN61800-5-2 / EN62061 / IEC61508

Restriction of hazardous substances

RoHS2

Registration evaluation and authorisation of chemicals

Reach

Earth leakage current

EN 61800-5-1: 2007. Test techniques EN 60990:2000. 1x230 VA < 2,5 mA, 3x400VAC < 4,65 during runing

DC Bus discharge time

EN 61800-5-1:2007

Electrostatic discharge

EN 61800-3:2004+A1-2012. Test techniques EN 61000-4-2:2009.

Dielectric strength

61800-5-1: 2007

Surge

EN 61800-3: 2004+A1-2012. Test techniques EN 61000-4-5:2006.

Electrical fast transient burst

EN 61800-3: 2004+A1-2012. Test techniques EN 61000-4-4:2004.

Ambient conditions

Temperature operation

-10 to 50 °C

Humidity

95% max, non-condensing

Maintenance

Fault memory

Last 4 Trips stored with time stamp

Data logging

Logging of data prior to trip, Current, Temperature, DC Bus Voltage

Maintenence indicator

Yes. Onboard service life monitoring

Monitoring

Hours Run Meter, kWh/MWh meter

 

 

100% Taiwan Origin

Beijer Vietnam

Model: BFI-P2-24-0095-3F42-MN
 Frequency Inverter
 Input:380-480V +/- 10%, 3Phase, Output: 0-500V, 9.5A, 4kW, 3 Phase, max Amb: 50oC/
 (Replaced for phased-out BFI-P2-24-0095-3F42-SN )

 

 

Liên hệ & Báo giá chi tiết:

Sale ANS Vietnam:

support@ansgroup.asia

  Trực tiếp FaceBook

 Trực tiếp Zalo: 0911472255 

=====================================================

Click xem thêm ứng dụng sản phẩm khác

Đại lý phân phối chính hãng tại Vietnam 

Báo giá ngay – Hàng chính hãng – Bảo hành 12 tháng – Tư vấn hỗ trợ kỹ thuật 24/7 

Xem thêm sản phẩm hãng Beijer tại đây

Xem thêm thông tin về thương hiệu khác tại đây

Xem thêm sản phẩm khác tại đây