Product Identification

  • Manufacturer: PCB Piezotronics, Inc.

  • Model: 356A01.

  • Product Type: Miniature Triaxial ICP® Accelerometer.

  • Sensing Technology: Piezoelectric.

  • Signal Conditioning Technology: ICP® / IEPE.

  • Measurement Axes: X, Y and Z.

Performance Specifications

  • Nominal Sensitivity: 5 mV/g.

  • SI Sensitivity: 0.51 mV/(m/s²).

  • Sensitivity Tolerance: ±20%.

  • Measurement Range: ±1,000 g peak.

  • SI Measurement Range: ±9,810 m/s² peak.

  • X-Axis Frequency Range (±5%): 2–5,000 Hz.

  • Y- and Z-Axis Frequency Range (±5%): 2–8,000 Hz.

  • X-Axis Frequency Response (+1 dB): ≥8 kHz.

  • Resonant Frequency: ≥50 kHz.

  • Typical Broadband Resolution (1–10,000 Hz): 0.003 g RMS.

  • SI Broadband Resolution: 0.03 m/s² RMS.

  • Nonlinearity: ≤1%.

  • Transverse Sensitivity: ≤5%.

Electrical Specifications

  • Excitation Voltage: 18–30 VDC.

  • Constant Current Excitation: 2–20 mA.

  • Output Impedance: ≤200 Ω.

  • Output Bias Voltage: 7–12 VDC.

  • Discharge Time Constant: 0.24–1.0 seconds.

  • Settling Time Within 10% of Bias: Less than 3 seconds.

Typical Spectral Noise

  • At 1 Hz: 1,200 µg/√Hz.

  • At 10 Hz: 300 µg/√Hz.

  • At 100 Hz: 100 µg/√Hz.

  • At 1 kHz: 30 µg/√Hz.

Physical Specifications

  • Sensing Element: Ceramic.

  • Sensing Geometry: Shear.

  • Housing Material: Titanium.

  • Sealing: Hermetic.

  • Height: 6.35 mm.

  • Length: 6.35 mm.

  • Width: 6.35 mm.

  • Typical Sensor Weight Without Cable: 1.0 g.

  • Electrical Connection: Integral cable.

  • Electrical Connection Position: Side.

  • Integral Cable Length: 5 ft (approximately 1.5 m).

  • Cable Type: 034, four-conductor shielded cable.

  • Mounting Method: Adhesive.

Environmental Specifications

  • Operating Temperature Range: -54°C to +121°C.

  • Shock Overload Limit: ±10,000 g peak.

  • SI Shock Overload Limit: ±98,100 m/s² peak.

  • Temperature Response: Refer to the manufacturer's temperature response graph.

Typical Applications

  • Miniature electronic component vibration testing.

  • Printed circuit board qualification.

  • Lightweight structural vibration measurement.

  • Product reliability and durability testing.

  • Experimental modal analysis.

  • Automotive NVH testing.

  • Environmental stress screening.

  • Laboratory dynamic acceleration measurements.

Important Technical Notes

The 1.0-gram sensor weight excludes the integral cable. Cable routing and mounting conditions must therefore be considered when testing lightweight structures.

The frequency response differs between the X-axis and the Y/Z axes.

The shock overload limit of ±10,000g is not the normal measurement range of the accelerometer.

The standard 356A01 requires compatible ICP®/IEPE constant-current excitation and does not provide a conventional 4–20mA transmitter output.

Specifications apply at room temperature unless otherwise stated.