Product characteristics
Magnetic-inductive flow meter
Connector
Process connection: G2 flat seal
connection to pipe by means of an adapter
Empty pipe detection
2 outputs
OUT1 = analogue signal temperature
OUT2 = analogue signal flow
4-digit alphanumeric display
Display units: l/min, m³/h, gpm, gph, °C, °F
Measuring range
5...600 l/min (1.3...158.5 gpm)
 Application
Application   Conductive liquids
(conductivity:>= 20 µS/cm / viscosity: < 70 mm²/s at 40 °C)
Pressure rating [bar]   16
Medium temperature [°C / °F]   -10...70 / 14...158
 Electrical data
Electrical design   DC
Operating voltage [V]   18...32 DC ¹)
Current consumption [mA]   < 150
Insulation resistance [MΩ]   > 100 (500 V DC)
Protection class   III
Reverse polarity protection   yes
 Outputs
Output function   OUT1: analogue (4...20 mA) or IO-Link
OUT2: Analogue (4...20 mA)
Analogue output   4...20 mA; ≤ 22 mA
Max. load [Ω]   500
 Measuring / setting range
Flow monitoring
Measuring range   5...600 l/min 0.3...36 m³/h 80...9510 gph 1.3...158.5 gpm
Display range   -720...720 l/min -43.2...43.2 m³/h -11410...11410 gph -190.2...190.2 gpm
Resolution   0.5 l/min 0.02 m³/h 5 gph 0.1 gpm
Analogue start point, ASP   0...480 l/min 0...28.8 m³/h 0...7610 gph 0...126.8 gpm
Analogue end point, AEP   120...600 l/min 7.2...36 m³/h 1900...9510 gph 31.7...158.5 gpm
Low flow cut-off, LFC   5...15 l/min 0.3...0.9 m³/h 80...240 gph 1.3…4 gpm
in steps of   0.5 l/min 0.02 m³/h 5 gph 0.1 gpm
Measuring dynamics   1:120
Temperature monitoring
Measuring range [°C / °F]   -20...80 / -4...176
Display range [°C / °F]   -40...100 / -40...212
Resolution [°C / °F]   0.2 / 0.5
Analogue start point, ASP [°C / °F]   -20...60 / -4...140
Analogue end point, AEP [°C / °F]   0...80 / 32...176
in steps of [°C / °F]   0.2 / 0.5
 Accuracy / deviations
Flow monitoring
Accuracy [% of the final value]   ± (0.8% MW + 0.5% MEW) ³)
Repeatability   ± 0.2% MEW
Pressure loss (dP) / flow rate (Q)  
Temperature monitoring
Accuracy [K]   ± 1 (25 °C; Q > 15 l/min) / ± 1 (77 °F; Q > 4 gpm)
Temperature drift   ± 0.0333 °C / K; ± 0.0599 °F / K
 Reaction times
Power-on delay time [s]   5
Flow monitoring
Response time [s]   < 0.35 (dAP = 0)
Damping, dAP [s]   0...5
Temperature monitoring
Response time [s]   T09 = 3 (Q > 15 l/min) / T09 = 3 (Q > 4 gpm)
 Software / programming
Programming options   Display can be deactivated; Display unit; Empty pipe detection
 Interfaces
IO-Link Device
Transfer type   COM2 (38.4 kBaud)
IO-Link revision   1.1
SDCI standard   IEC 61131-9 FDIS
IO-Link Device ID   379 d / 00 01 7B h
Profiles   Smart Sensor: Process Data Variable; Device Identification
SIO mode   no
Required master port type   A
Process data analogue   3
Process data binary   2
Min. process cycle time [ms]   5
 Environment
Ambient temperature [°C / °F]   -10...60 / 14...140
Storage temperature [°C / °F]   -25...80 / -13...176
Protection   IP 65 / IP 67
 Tests / approvals
Pressure equipment directive   Article 3, section 3 - sound engineering practice
EMC   DIN EN 60947-5-9
Shock resistance  
DIN EN 60068-2-27 20 g (11 ms)  
Vibration resistance  
DIN EN 60068-2-6 5 g (10...2000 Hz)  
MTTF [Years]   78
 Mechanical data
Process connection   G2 flat seal
Materials (wetted parts)   stainless steel 316L / 1.4404; stainless steel 316Ti / 1.4571; PEEK (polyether ether ketone); Hastelloy C-4 (2.4610); Centellen; FKM
Housing materials   stainless steel 316L / 1.4404; stainless steel 316Ti / 1.4571; PEI; FKM; PBT-GF 20; elastolan
Weight [kg]   3.065
 Displays / operating elements
Display  
Display unit  6 x LED green (l/min, m³/h, gpm, gph, °C, °F)
Function display  1 x LED yellow (10³)
Measured values  4-digit alphanumeric display
Programming  4-digit alphanumeric display
 Electrical connection
Connection   M12 connector; Gold-plated contacts
Wiring
Core colours
BK black
BN brown
BU blue
WH white
Colours to DIN EN 60947-5-6
------------------------
OUT1:
Temperature monitoring
IO-Link ²)
OUT2:
Flow monitoring
 Accessories
Accessories (included)   2 x packing washer (Centellen); Label
 Remarks
Remarks  
¹) to DIN EN 50178, SELV, PELV
²) IO-Link communication must be activated in the menu.
³) Q > 15l/min, medium and ambient temperature +22 °C ± 4K (+72 °F ± 7 °F)
MW = measured value
MEW = final value of the measuring range
Pack quantity [piece]   1