Đại lý phân phối Vaisala tại Vietnam,Humidity and Temperature Transmitter HMT330 4H0B001BCXA100A0AAEBAA1 Vaisala
100% Finland Origin
|
Vaisala
|
HMT330 4H0B001BCXA100A0AAEBAA1
Humidity and Temperature Transmitter
Transmitter Type: HMT334 for pressurized processes
Probe 2m +180C,0-25MPa
NO Additional temperature probe
Cod RH+T+Td+a+Tw+x+h+pws
NO Display
Power Supply: Standard (10...35V,24VAC)
Signal Output: Analog Output 4...20mA
Analog Output signal for Ch1: (0...100%RH)
Analog output signals for Ch2: See Below
Analog output signals for Ch3: Special (confirm when order)
NO Analog output range for Temp
Metric Units Output
No Option for module slot 1
NO Option for module slot 2
Cable Bushings: Sealed Cable Gland M20x1.5
NO Transmitter installation
Humidity sensor: General purpose HUMICAP180R
Sensor protection: PPS Grid with Steel Netting
Installation Kit for Probe: Fitting Body M22x1.5
User´s Guide HMT330 English
No PC Accessories
No Calibration Contract ISO9001 Calibration
No Maintenance Contract
|
100% Finland Origin
|
Vaisala
|
HMT330 1A0B001BCXA100A0AAABAA1
Humidity and Temperature Transmitter
Transmitter Type: HMT331 for wall mounting
Probe cable: Fixed
NO Additional temperature probe
Cod RH+T+Td+a+Tw+x+h+pws
NO Display
Power Supply: Standard (10...35V,24VAC)
Signal Output: Analog Output 4...20mA
Analog Output signal for Ch1: (0...100%RH)
Analog output signals for Ch2: See Below
Analog output signals for Ch3: Special (confirm when order)
NO Analog output range for Temp
Metric Units Output
No Option for module slot 1
NO Option for module slot 2
Cable Bushings: Sealed Cable Gland M20x1.5
NO Transmitter installation
Humidity sensor: General purpose HUMICAP180R
Sensor protection: PPS Grid with Steel Netting
NO Installation Kit for Probe
User´s Guide HMT330 English
No PC Accessories
No Calibration Contract ISO9001 Calibration
No Maintenance Contract
|
100% Finland Origin
|
Vaisala
|
DMT340 4H0B1A1BKA2A001A1A2B0A0
DMT344 Dewpoint & Temperature Transmitter for Pressurized Processes
Probe: Probe 2m +180C,0-25MPa
No Temperature Probe
Code Td/f+PPM+x+RH+T
With Display
Power Supply: Standard (10..35V,24VAC)
Analog Output Signal for (Ch1&Ch2&Ch3): 4...20mA
Analog Output Scaling for Ch1: Tdf (-80...+20C)
Analog Output Scaling for Ch2: (0...100%RH)
No Analog Outputs for Ch3
Pressure Setting for Optimized Accuracy 3 bar
Metric Units
User Cable Connection: Sealed Cable Gland M20x1.5
Dewpoint Sensor: Drycap180m2 Sensor
Sensor Protection: Sintered Filter AISI 316L HM47280
Probe Installation Accessories: Fitting Body M22x1.5
User's Guide DMT340 English
Calibration: Dewpoint Calibration NIST Traceable
|
=====================================================
ANS là đại lý phân phối chính hãng Vaisala tại Vietnam
Báo giá ngay - Hàng chính hãng - Bảo hành 12 tháng - Tư vấn hỗ trợ kỹ thuật 24/7