Monitoring and Protection System for highest safety requirements up to SIL3

  • TMR (triple-modular-redundant) system with sensor monitoring and self-test
  • Highest safety levels with maximum availability by unique and true 2oo3 architecture for each trip criterion within each Monitor
  • Maintenance-free during lifetime due to integrated automatic proof tests
  • Automated tests of one or two 2oo3 solenoid valve blocks with permanent monitoring of the feedback by the Test Generator
  • Minimal Total Cost of Ownership
  • Requires less than 1% of the permissible PFD value for a SIL3 Safety Loop
  • Enhanced safety values due to an integrated Test Generator
  • Replacement of all active components during operation (Hot Swap)
  • TÜV certified for safety level SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2008
  • TÜV certified for SILCL3 / IEC 62061:2005
  • API670 and API612 compliant
  • 2 PROFIBUS Interfaces
  • Additional features for E16E368 MAN:
    • Up to 12 load outputs with 2oo3 technique for E/H-Converter or valves
    • 30 additional digital inputs for 10 digital trip criteria
    • 15 additional analog inputs for 5 analog trip criteria
    • Last Blade Protection
    • Counters for number of starts and for hours of operation