·   Measuring range 0 – 500 m

·   Accuracy +/- 1 mm

·   For objects up to +1300 °C

·   Parameterization with RS 485 + Software

·   Analog output 4 – 20 mA

 

 

·   3 switching outputs (can be parameterized)

 

·   Trigger input

·   Plug S8 (M12)

·   G3/4“ tread for protection hose connection

 

 

 

Product Characteristics

Type                                                         LMA 100

Art.-No.                                                            5200B

Application                                                       distance measuring on hot objects, positioning in furnaces, hot rolling, pressing, forging, heat treatment

 

 

Technical Data

Measuring range                                              0 – 500 m* (can be parameterized) Measurement accuracy max.                           +/- 1 mm

Laser                                                                Laser class 2

Trigger function                                                Single distance measuring at external trigger signal Continuous measurement                               Automatically distance measuring accuracy optimized Quick continuous measurement                      Automatically distance measuring speed optimized Supply voltage                                                 12 - 30 V DC

Ripple                                                               max. 10 % Current consumption                                       < 200 mA

Analog output                                                   4 – 20 mA (12-Bit resolution) Load impedance                                              100 – 500 W

Digital communication                                      RS 485 MODBUS RTU

Trigger input                                                     12 – 30 V DC

Output                                                              3x PNP normally open / normally closed (can be parameterized) Continuous current                                          0 - 400 mA

Short-circuit protection                                     yes, pulsing Voltage drop                                                    < 2,5 V Response time                                                 10 ms – 1,5 s Readiness delay                                        7 s

Ambient temperature                                       -10 … +40 °C Protection class                                               IP 67

Housing material                                              Stainless steel Functional display                                            Duo-LED red/green Status display                                                  RGB-LED

Connection device                                           plug S8  (M12 x 1 A) 8 pole with G3/4“ protective hose thread

Connection interface                                        plug S4 (M12 x 1 A) 5 pole

Weight

 

* referred to a target plate Oralite 5200. At an object with reflectivity 80% measuring range max. 100 m. At an object with reflectivity 6%

measuring range max. 65 m.

 

 

 

 

 

 

 

 

 

 

 

21.10.2016 mk  Details are subject to change without notice.                                                                                                                                                     page 1 of 3

 

 

 

Connection

 

 

 

 

 

 

Only for parameterization

 

 

 

 

 

  Dimension (mm)                                                                                                                                           

 

 

 

 

 

 

 

 

 

 

21.10.2016 mk  Details are subject to change without notice.                                                                                                                                                     page 2 of 3

 

 

Accessories (not in scope of supply )

 

 

Type

Art.-No.

Connection cable with female straight plug S8 (M12 x 1 A) 2 m PVC cable 8 x 0,25 mm² up to 80 °C

ST S8-2

9850O

Connection cable with female straight plug S8 (M12 x 1 A) 5 m PCV cable 8 x 0,25 mm² up to 80 °C

ST S8-5

9850N

Connection cable with female straight plug S8 (M12 x 1 A) 10 m PCV cable 8 x 0,25 mm² up to 80 °C

ST S8-10

9850S

Swivel stand

HM 2

9816B

Adapter for protection hose connection (suitable protection hoses available)

HG 2

9855B

Tube

OL 19

9828A

Air purge attachment

OL 34

9828Q

Tube for Air purge attachment

OL 36

9828S

Interface converter RS485, female plug  S4 (M12 x 1 A) 5-pole to USB

SIC 485U

9861B

Power supply 90-260 VAC, 24 VDC / 1 A

PPS 2

9853B

 

Further Information

 

 

 

Dokument

 

Manual                                                                                                                                        BDA_LMB100_D_E

Protection hoses                                                                                                                        P46