order no.mic+600/D/TC
  •  1 x pnp
 
  •  8,000 mm
measuring range600 - 8.000 mm
designcylindrical M30
operating modeproximity switch/reflective mode
reflective barrier
window mode
particularitiesDisplay
UL Listed
means of measurementecho propagation time measurement
transducer frequency80 kHz
blind zone600 mm
operating range6,000 mm
maximum range8,000 mm
resolution/sampling rate0.18 mm
reproducibility± 0.15 %
accuracy± 1 % (temperature drift internally compensated)
operating voltage UB9 - 30 V d.c., reverse polarity protection
voltage ripple± 10 %
no-load current consumption≤ 80 mA
type of connection5-pin M12 initiator plug
output 1switching output
pnp: Imax = 200 mA (UB-2V)
NOC/NCC adjustable, short-circuit-proof
switching hysteresis100 mm
switching frequency3 Hz
response time240 ms
delay prior to availability< 450 ms
input 1com input
synchronisation input
materialbrass sleeve, nickel-plated, plastic parts, PBT, TPU
ultrasonic transducerpolyurethane foam, epoxy resin with glass contents
class of protection to EN 60529IP 67
operating temperature-25°C to +70°C
storage temperature-40°C to +85°C
weight270 g
further versionsstainless steel
cable connection (on request)
further versionsmic+600/D/TC/E
temperature compensationyes
controls2 push-buttons + LED display (TouchControl)
scope for settingsTeach-in and numeric configuration via TouchControl
LCA-2 with LinkControl
Synchronisationyes
multiplexyes
indicators3-digit LED display, 2 x three-colour LED
particularitiesDisplay
UL Listed