GPR-1500 AIS ATEX, CSA, UL TRACE PPM OXYGEN ANALYZER
Giá bán: Liên hệ
Hãng sản xuất: Aii Vietnam
Danh mục: Thiết bị trong dây chuyền sản xuất
Nhà cung cấp: anh nghi son
Xuất sứ:
Bảo hành: 12
GPR-1500 AIS ATEX, CSA, UL TRACE PPM OXYGEN ANALYZER
Natural gas PPM oxygen transmitter features certification to ATEX Directive 94/9/EC (view all ATEX certified products), and cUL designed exclusively for Natural Gas applications, this analyzer features an advanced galvanic trace PPM oxygen sensor capable of precisely measuring oxygen concentrations ranging from 0.01 PPM to 1% over a 18 month operating sensor operating life, menu driven controls, two (2) field selectable alarm set points. Pictured with optional A-3393 modular sample system designed to remove moderate amounts of free liquids and H2S from natural gas streams.
Certifications:
ULc Class I Div I Group C, D
ATEX Directive 94/9/ II 2G
Ex d [ib] ib IIB T4 Gb
Tamb -10oC to 50oC
*Accuracy: | < 2% of FS range under constant conditions | Analysis Ranges: | 0-10 PPM, 0-100 PPM, 0-1000 PPM, 0-1%, 0-25% FS ranges; |
Application: | Oxygen analysis in inert, hydrocarbon, hydrogen, mixed and acid (CO2) gas streams | Approvals: | ATEX Directive 94/9/EC II 2 G Ex d [ib] ib IIB T4 Gb Tamb -20⁰C to +50⁰C |
Area Classification: | cUL for Class 1, Division 1, Group C, D hazardous | Alarms: | Two user configurable alarms: relays rated 3A at 100 VAC, alarm time delays, alarm bypass, power/system fail alarm |
Calibration: | Air or certified span gas of O2 balance N2 | Compensation: | Barometric pressure and temperature |
Connections: | 1/8″ compression tube fittings | Controls: | Menu driven range selection, calibration and system functions |
Display: | Graphical LCD 2.75” x 1.375”; resolution 0.01 PPM; displays real time ambient temperature and pressure |
Enclosure: | Aluminum ex-proof, fiberglass Type R3, 16x9x6”, 20 lbs. |
Flow: | 1-5 SCFH, 1-2 SCFH recommended | Linearity: | >0.995 over all ranges |
Pressure: | Inlet – regulate to 5-30 psig to deliver 1-2 SCFH flow to transmitter; vent – atmospheric |
Power: | 12-24 VDC or 100/230 VAC (ATEX only) |
Response Time: | 90% of final reading in 10 seconds | Sample System: | Flow control/meter, sample/span valve |
Sensitivity: | < 0.5% of FS range | Sensor Model: | XLT-12-333 for gases containing > 0.5% CO2 |
Sensor Life: | 24 months at 25ºC and 1 atm. | Signal Output: | 4-20 mA non loop current |
Operating Range: | Recommended -10ºto 45ºC | Warranty: | 12 months analyzer; 12 months sensor |
Weted Parts: | Stainless steel | Communication: | Optional Mod-bus communication |