Xuất sứ:
- Color/absorption measurement in liquids
- Concentration measurement of substances by absorption at characteristic wavelengths
- Calibration in E/m, APHA-Hazen, EBC, ASTM, Saybolt, etc.
- Combined online measurement of DOC (UV absorption) and colour (Hazen) in one instrument
- Dual-beam measurement for high stability
- Flow cell easy to clean without tools
- Fast and simple verification with control unit
- Effective optical compensation of flow cell window contamination
- Option: Turbidity compensation using a second wavelength
The ColorPlus measures the colour/absorbance online at up to three different wavelengths. The bypass measuring cell has been specifically designed for applications within the water industry. Depending on the configuration it allows measuring DOC (UV absorption) and colour (Hazen) simultaneously and to compensate turbidity. Soiling of the flow cell is measured by means of a compensation glass in the interior of the flow cell. The effect of cell soiling is greatly reduced internally; constant and precise measured values are guaranteed. The user is alerted if the cell has to be cleaned. The cover of the flow cell can be opened without tools and allows simple access for cleaning the flow cell. For inspecting the instrument, checking units on the basis of reference filters can easily be inserted. Operation is done intuitive using the intelligent control system SICON via touch screen technology and colour display. Values, graphs, alarm and status messages can be presented. An internal data logger allows recalling and displaying measured data from the last 32 days. A variety of analogue and digital interfaces allows smooth system integration and control.
Measuring principle |
Absorption |
0 .. 3 E |
|
Scale ranges |
8, freely configurable |
Resolution |
0.001 E |
Enclosure |
Stainless steel 304 / 1.4301 |
Protection |
IP65 |
Flow cell material |
PVC 100 mm / 50 mm |
Sample flow rate |
0.5 .. 1 l/min |
Sample temperature |
0 .. 50 °C |
Sample pressure |
600 kPA (6 bar) |
Ambient temperature |
-20 .. +50 °C |
Weight |
4.3 kg |
Connections |
Inlet / Outlet Ø 9 mm o.d. |
Wavelengths UV |
254 nm, 313 nm, 365 nm, 436 nm, 546 nm |
Wavelengths VIS |
365 nm, 380 .. 700 nm |
Units |
E, E/m, Hazen, GOST |
Windows material |
Borosilicate (VIS), Quartz (UV) |
Seal material |
EPDM |
Highest measuring range | 0 - 150 GOST Color |
Applications in | Drinking Water Treatment |
Lowest measuring range | 0-0.05 E |
Highest measuring range | 0-3 E |
Applications in | Drinking Water Treatment |
Lowest measuring range | 0-0.05 E |
Highest measuring range | 0-3 E |
Applications in | Drinking Water Treatment |
Lowest measuring range | 0-0.05 E |
Highest measuring range | 0-3 E |
Applications in | Chemical / Pharmaceutical Industry |
Lowest measuring range | 0-0.05 E |
Highest measuring range | 0-3 E |
Applications in | Chemical / Pharmaceutical Industry |
Lowest measuring range | 0-0.05 E |
Highest measuring range | 0-3 E |
Applications in | Chemical / Pharmaceutical Industry |
Machine and Metal Industry | |
Petrochemical Industry / Refinery |
Lowest measuring range | 0-0.05 E |
Highest measuring range | 0-3 E |
Applications in | Chemical / Pharmaceutical Industry |
Lowest measuring range | 0-1 E/m |
Highest measuring range | 0-60 E/m |
Applications in | Drinking Water Treatment |
Lowest measuring range | 0-1 E/m |
Highest measuring range | 0-60 E/m |
Applications in | Drinking Water Treatment |
Lowest measuring range | 0-1 E/m |
Highest measuring range | 0-60 E/m |
Applications in | Drinking Water Treatment |
Emission Monitoring | |
Pulp / Paper Industry | |
Waste Water Treatment |
Lowest measuring range | 0-1 E/m |
Highest measuring range | 0-60 E/m |
Applications in | Drinking Water Treatment |
Lowest measuring range | 0-0.3 FLU |
Highest measuring range | 0-100 FLU |
Applications in | Chemical / Pharmaceutical Industry |
Machine and Metal Industry | |
Petrochemical Industry / Refinery | |
Power Plants | |
Ship Industry |
Lowest measuring range | 0-0.05 E |
Highest measuring range | 0-3 E |
Applications in | Chemical / Pharmaceutical Industry |
Petrochemical Industry / Refinery |
Lowest measuring range | 0-0.01 FNU |
Highest measuring range | 0-4000 FNU |
Applications in | Brewing Industry |
Chemical / Pharmaceutical Industry | |
Drinking Water Treatment | |
Emission Monitoring | |
Food Industry | |
Machine and Metal Industry | |
Petrochemical Industry / Refinery | |
Power Plants | |
Pulp / Paper Industry | |
Soft Drink / Fruit Juice Industry |
Lowest measuring range | 0-1 E/m |
Highest measuring range | 0-60 E/m |
Applications in | Waste Water Treatment |
Industry | Measuring Point |
---|---|
Brewing Industry |
Turbidity in Raw Water |
Chemical / Pharmaceutical Industry |
Application undisclosed |
Drinking Water Treatment |
Colour (GOST Standard) in Water |
Emission Monitoring |
DOC (UV Absorption) in Raw Water |
Food Industry |
Turbidity in Raw Water |
Machine and Metal Industry |
Concentration of Copper in Sulphuric Acid (H2SO4) |
Petrochemical Industry / Refinery |
Colour in Process Water / Waste Water |
Power Plants |
Colour in Process Water / Waste Water |
Pulp / Paper Industry |
Colour in Process Water / Waste Water |
Ship Industry |
Oil (HC) Traces in Condensate |
Soft Drink / Fruit Juice Industry |
Turbidity in Raw Water |
Waste Water Treatment |